• Title/Summary/Keyword: ARM

Search Result 4,903, Processing Time 0.04 seconds

Inter-GuestOS Communications in Multicore-based ARM TrustZone (멀티코어 프로세서 기반 ARM TrustZone 환경에서의 게스트 운영체제 간 통신)

  • Jeon, Moowoong;Kim, Sewon;Yoo, Hyuck
    • Journal of KIISE
    • /
    • v.42 no.5
    • /
    • pp.551-557
    • /
    • 2015
  • The technology using ARM TrustZone draws attention as a new embedded virtualization approach. The ARM TrustZone defines two virtual execution environment, the secure world and the normal world. In such an environment, the inter-world communication is important to extend function of software. However, the current monitor software does not sufficiently support the inter-world communication. This paper presents a new inter guestOS communication scheme, for each world, for the ARM TrustZone virtualization. The proposed communication scheme supports bidirectional inter-world communication for single core and multicore environment. In this paper, It is implemented on a NVIDIA Tegra3 processor based on the ARM Cortex-A9 MPCore and it showed a bandwidth of 30MB/s.

Effects of Passive Scapular Postural Correction and Active Scapular Posterior Tilt Strategies on Peri-scapular Muscle Activation (수동적 어깨뼈 자세 교정 전략과 능동적 어깨뼈 뒤쪽 기울임 전략이 어깨뼈 주변근육 활성도에 미치는 영향)

  • Kang, Min-Hyeok
    • PNF and Movement
    • /
    • v.20 no.2
    • /
    • pp.215-222
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the effects of passive scapular upward rotation and posterior tilt and active scapular posterior tilt on the muscle activity of the upper trapezius (UT), lower trapezius (LT), and serratus anterior (SA). Methods: Fifteen healthy subjects performed general arm elevation, arm elevation with passive scapular upward rotation and posterior tilt, and arm elevation with active scapular posterior tilt. For active scapular posterior tilt, the subjects were trained in this movement using visual biofeedback and a motion sensor. During each arm elevation condition, electromyography was used to measure the muscle activity of the UT, LT, and SA. The measured data were analyzed using a one-way repeated ANOVA. Results: LT muscle activity was significantly increased during arm elevation with active scapular posterior tilt compared to both general arm elevation and arm elevation with passive scapular upward rotation and posterior tilt (p < 0.05). SA muscle activity was greater during arm elevation with passive scapular upward rotation and posterior tilt than during general arm elevation (p < 0.05). There was no significant change in UT muscle activity among the tested arm elevation conditions (p > 0.05). Conclusion: Performing arm elevation with active scapular posterior tilt and performing arm elevation with passive scapular upward rotation and posterior tilt may be useful strategies for increasing muscle activation of the LT and SA, respectively.

Fast Laser Triangular Measurement System using ARM and FPGA (ARM 및 FPGA를 이용한 고속 레이저 삼각측량 시스템)

  • Lee, Sang-Moon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.1
    • /
    • pp.25-29
    • /
    • 2013
  • Recently ARM processor's processing power has been increasing rapidly as it has been applied to consumer electronics products. Because of its computing power and low power consumption, it is used to various embedded systems.( including vision processing systems.) Embedded linux that provides well-made platform and GUI is also a powerful tool for ARM based embedded systems. So short period to develop is one of major advantages to the ARM based embedded system. However, for real-time date processing applications such as an image processing system, ARM needs additional equipments such as FPGA that is suitable to parallel processing applications. In this paper, we developed an embedded system using ARM processor and FPGA. FPGA takes time consuming image preprocessing and numerical algorithms needs floating point arithmetic and user interface are implemented using the ARM processor. Overall processing speed of the system is 60 frames/sec of VGA images.

Analysis of Human Arm Movement During Vehicle Steering Maneuver

  • Tak, Tae-Oh;Kim, Kun-Young;Chun, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.spc1
    • /
    • pp.444-451
    • /
    • 2005
  • The analysis of human arm motion during steering maneuver is carried out for investigation of man-machine interface of driver and steering system Each arm is modeled as interconnection of upper arm, lower arm, and hand by rotational joints that can properly represents permissible joint motion, and both arms are connected to a steering wheel through spring and damper at the contact points. The joint motion law during steering motion is determined through the measurement of each arm movement, and subsequent inverse kinematic analysis. Combining the joint motion law and inverse dynamic analysis, joint stiffness of arm is estimated. Arm dynamic analysis model for steering maneuver is setup, and is validated through the comparison with experimentally measured data, which shows relatively good agreement. To demonstrate the usefulness of the arm model, it is applied to study the effect of steering column angle on the steering motion.

Implementation of ARM11 Platform for Gas Sensor Based on Embedded Linux (Embedded Linux를 기반으로 한 Gas센서용 ARM11 플랫폼 구현에 관한 연구)

  • Ahn, Jong-Chan;Kim, Young-Kil;Na, Sang-Sin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1335-1343
    • /
    • 2009
  • This paper focuses on the implementation of hand held typeARM11 Platform for gas sensor based on Embedded Linux OS. The S3C6400, which is ARM11 architecture based, is the key component of the ARM11 Platform, Bluetooth is adapted to consist the network for the wireless transmission of environmental data between a sensor node and hand held type ARM11 Platform. Linux is ported to the Platform, QT/embedded is used for the application development.

Virtual ARM Machine for Embedded System Development (임베디드 시스템의 가상 ARM 머신의 개발)

  • Lee, So-Jin;An, Young-Ho;Han, Alex H;Hwang, Young-Si;Chung, Ki-Seok
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.3 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • To reduce time-to-market, more and more embedded system developers and system-on-chip designers rely on microprocessor-based design methodology. ARM processor has been a major player in this industry over the last 10 years. However, there are many restrictions on developing embedded software using ARM processor in the early design stage. For those who are not familiar with embedded software development environment or who cannot afford to have an expensive embedded hardware equipment, testing their software on a real ARM hardware platform is a challenging job. To overcome such a problem, we have designed VMA (Virtual ARM Machine), which offers easier testing and debugging environment to ARM based embedded system developers. Major benefits that can be achieved by utilizing a virtual ARM platform are (1) reducing development cost, (2) lowering the entrance barrier for embedded system novices, and (3) making it easier to test and debug embedded software designs. Unlike many other purely software-oriented ARM simulators which are independent of real hardware platforms, VMA is specifically targeted on SYS-Lab 5000 ARM hardware platform, (designed by Libertron, Inc.), which means that VMA imitates behaviors of embedded software as if the software is running on the target embedded hardware as closely as possible. This paper will describe how VMA is designed and how VMA can be used to reduce design time and cost.

  • PDF

Development of an electronic protection simulator using decoy antenna (디코이 안테나를 이용한 전파회피 모사기 개발)

  • Lim, Joong-Soo;Chae, Gyoo-Soo;Kim, Min-Nyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2528-2533
    • /
    • 2010
  • This paper describes on a software simulator that can be used for an anti-ARM system. The proposed simulator is a valuable tool for investigating the optimum deployment of decoy antennas which are widely using for anti-ARM and calculating the electromagnetic field at the ARM receiver. To verify the effect of decoy antennas, we analyze the field intensity and phase at the receiver. We conduct an analysis of ARM attack in case of using multiple decoy antennas and the proposed simulator can be used to decide the optimum positions of the decoys.

Effect of Arm Sling on Walk Speed and Energy Consumption in Patients with Stroke (팔걸이가 뇌졸중 환자의 보행속도 및 에너지 소모량에 미치는 영향)

  • Yoon, Seoung-Ic;Kim, Yoon-Shin;Shim, Jae-Hun;Oh, Kyung-Ah;Oh, Duck-Won;Chon, Seung-Chul
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.1
    • /
    • pp.39-45
    • /
    • 2008
  • This study was undertaken to identify the influence which affect on gait speed and energy consumption regarding putting on arm sling during gait of the 40 hemiplegic patients selected from University Hospital and rehabilitation center in seoul during two months. The analysis of data was performed using the paired samples ttest to compare the differences of gait velocity, heart rate, oxygen consumption and oxygen cost in gait of preand post- arm sling. The results of this study were as follows; 1. When comparing the result before putting on arm sling in the gait of hemiplegic patient, gait velocity after putting on arm sling was statistically significantly increased(p<.05). 2. When comparing the result before putting on arm sling in the gait of hemiplegic patient, heart rate after putting on arm sling was statistically significantly decreased(p<.05). 3. When comparing the result before putting on arm sling in the gait of hemiplegic patient, oxygen consumption per weight after putting on arm sling was statistically significantly decreased(p<.05). 4. When comparing the result before putting on arm sling in the gait of hemiplegic patient, oxygen consumption rate per weight after putting on arm sling was statistically significantly decreased(p<.05). When putting together the above result, the gait with arm sling in comparison with the gait without arm sling was to increase gait velocity, decrease heart rate, decrease oxygen consumption and was finally to decrease energy consumption in the gait of hemiplegic patient.

  • PDF

Effects of Robot-Assisted Arm Training on Muscle Activity of Arm and Weight Bearing in Stroke Patients (로봇-보조 팔 훈련이 뇌졸중 환자의 팔에 근활성도와 체중지지에 미치는 영향)

  • Yang, Dae-jung;Lee, Yong-seon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.71-80
    • /
    • 2022
  • Background: This study investigated the effect of robot-assisted arm training on muscle activity of arm and weight bearing in stroke patients. Methods: The study subjects were selected 20 stroke patients who met the selection criteria. 10 people in the robot-assisted arm training group and 10 people in the task-oriented arm training group were randomly assigned. The experimental group performed robot-assisted arm training, and the control group performed task-oriented arm training for 6 weeks, 5 days a week, 30 minutes a day. The measurement tools included surface electromyography and smart insole system. Data were analyzed using independent sample t-test and the paired sample t-test. Results: Comparing the muscle activity of arm within the group, the experimental group and the control group showed significant differences in muscle activity in the biceps brachii, triceps brachii, anterior deltoid, upper trapezius, middle trapezius, and lower trapezius. Comparing the muscle activity of arms between the groups, the experimental group showed significant difference in all muscle activity of arm compared to the control group. Comparing the weight bearing within the groups, the experimental group showed significant difference in the affected side and non-affected side weight bearings and there were significant differences in anterior and posterior weight bearing. The control group showed significant difference only in the non-affected side weight bearing. Comparing the weight bearings between groups, the experimental group showed significant difference in the affected side and non-affected side weight bearings compared to the control group. Conclusion: This study confirmed that robot-assisted arm training applied to stroke patients for 6 weeks significantly improved muscle activity of arm and weight bearing. Based on these results, it is considered that robot-assisted arm training can be a useful treatment in clinical practice to improve the kinematic variables in chronic stroke patients.

An Investigation of Unsteady Response of Augmented Reduced Mechanism for Numerical Simulation of CH4 Nonpremixed Flames (CH4비예혼합화염의 수치계산에 적용하기 위한 확장된 축소반응기구의 비정상 응답특성 검토)

  • Oh, Chang-Bo;Park, Jeong;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.243-250
    • /
    • 2003
  • The extinction behavior and the unsteady response of augmented reduced mechanism(ARM) have been investigated by adopting an OPPDIF code and a numerical solver for the flamelet equations. By comparing the performance of the ARM based on Miller and Bowman's mechanism(MB-ARM) with that of the ARM based on GRI-Mech 3.0(GRI-3.0-ARM), it is identified that the MB-ARM is more suitable for the unsteady calculation because it is relatively less stiff than GRI-3.0-ARM during an ignition process. The steady results using the MB-ARM, which is modified to predict reasonably the extinction point of experiment, are in excellent agreement with those from full mechanism. Under the sinusoidal transient disturbances of scalar dissipation rate, the unsteady responses of the flame temperature and species concentrations using a modified MB-ARM show in very close agreement with those from full mechanism. It is presumed that above modified MB-ARM is very suitable for the unsteady simulation of turbulent flames because it gives not only a low computational cost but also a good prediction performance for flame structure, extinction point and unsteady response.