• 제목/요약/키워드: ARCH models

검색결과 278건 처리시간 0.025초

PRELIMINARY DETECTION FOR ARCH-TYPE HETEROSCEDASTICITY IN A NONPARAMETRIC TIME SERIES REGRESSION MODEL

  • HWANG S. Y.;PARK CHEOLYONG;KIM TAE YOON;PARK BYEONG U.;LEE Y. K.
    • Journal of the Korean Statistical Society
    • /
    • 제34권2호
    • /
    • pp.161-172
    • /
    • 2005
  • In this paper a nonparametric method is proposed for detecting conditionally heteroscedastic errors in a nonparametric time series regression model where the observation points are equally spaced on [0,1]. It turns out that the first-order sample autocorrelation of the squared residuals from the kernel regression estimates provides essential information. Illustrative simulation study is presented for diverse errors such as ARCH(1), GARCH(1,1) and threshold-ARCH(1) models.

Application of Wavenumber-TD approach for time harmonic analysis of concrete arch dam-reservoir systems

  • Lotfi, Vahid;Zenz, Gerald
    • Coupled systems mechanics
    • /
    • 제7권3호
    • /
    • pp.353-371
    • /
    • 2018
  • The Wavenumber or more accurately Wavenumber-FD approach was initially introduced for two-dimensional dynamic analysis of concrete gravity dam-reservoir systems. The technique was formulated in the context of pure finite element programming in frequency domain. Later on, a variation of the method was proposed which was referred to as Wavenumber-TD approach suitable for time domain type of analysis. Recently, it is also shown that Wavenumber-FD approach may be applied for three-dimensional dynamic analysis of concrete arch dam-reservoir systems. In the present study, application of its variation (i.e., Wavenumber-TD approach) is investigated for three-dimensional problems. The method is initially described. Subsequently, the response of idealized Morrow Point arch dam-reservoir system is obtained by this method and its special cases (i.e., two other well-known absorbing conditions) for time harmonic excitation in stream direction. All results for various considered cases are compared against the exact response for models with different values of normalized reservoir length and reservoir base/sidewalls absorptive conditions.

A Study on the Analysis of Construction Process for the Stressed-Arch System (Stressed-Arch 시스템의 시공 과정 해석에 관한 연구)

  • 김종범;윤종현;이경수;한상을
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.118-123
    • /
    • 2001
  • The objectives of this research are to verify the structural stability and estimate the resisting performance of Stressed-Arch system during the construction process. Full scale models are taken to obtain the objective shape by the Dynamic Relaxation Method. As a result, it measured more strain than yielding strain at the extreme fiber of top chord member on the crown, but it is shown that members have the sufficiently compressive resisting performance as well as a considerable strain recovery capacity under unloading. Therefore, it is confirmed that Stressed-Arch system apparently have sufficient range of the structural capacity, but it is required that the elasto-plastic behavior of this system must be verified more detailed by numerical analysis and experiments.

  • PDF

Change in arch width in extraction vs nonextraction treatment (발치 및 비발치 치료 전후 악궁 폭경의 변화)

  • Jeon, Ji-Yun;Kim, Su-Jung;Kang, Seung-Goo;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • 제37권1호통권120호
    • /
    • pp.65-72
    • /
    • 2007
  • Objective: This study was performed to investigate the influences of extraction and nonextraction treatment on smile esthetics by measuring dental arch width changes. Methods: Pretreatment and posttreatment study models of 30 first premolar extraction cases and 30 nonextraction cases were randomly selected to determine whether extraction treatment results in narrow dental arches, and a consequent unaesthetic smile. Arch widths were measured from the cusp tips of the canines and the first molars. Posterior arch widths were also measured at a constant arch depth derived by averaging randomly chosen nonextraction models. Results: The intercanine widths increased significantly in the extraction sample, whereas the intermolar widths decreased significantly. The arch width at a standardized arch depth was significantly wider in the extraction subjects. Conclusion: These results elucidate that constriction in arch width is not a materialized consequence of extraction treatment. It leads to postulate that an esthetically compromising effect from narrow dental arches on smile is hardly anticipated with extraction treatment.

Reference points suitable for evaluation of the additional arch length required for leveling the curve of Spee

  • Cho, Yong-Hwa;Lim, Sung-Hoon;Gang, Sung-Nam
    • The korean journal of orthodontics
    • /
    • 제46권6호
    • /
    • pp.356-363
    • /
    • 2016
  • Objective: The additional arch length required for leveling (AALL) the curve of Spee (COS) can be estimated by subtracting the two-dimensional (2D) arch circumference, which is the projection of the three-dimensional (3D) arch circumference onto the occlusal plane, from the 3D arch circumference, which represents the arch length after leveling the COS. The purpose of this study was to determine whether the cusp tips or proximal maximum convexities are more appropriate reference points for estimating the AALL. Methods: Sixteen model setups of the mandibular arch with COS depths ranging from 0 mm to 4.7 mm were constructed using digital simulation. Arch circumferences in 2D and 3D were measured from the cusp tips and proximal maximum convexities and used to calculate the AALL. The values obtained using the two reference points were compared with the paired t -test. Results: Although the 3D arch circumference should be constant regardless of the COS depth, it decreased by 3.8 mm in cusp tip measurements and by 0.4 mm in proximal maximum convexity measurements as the COS deepened to 4.7 mm. AALL values calculated using the cusp tips as reference points were significantly smaller than those calculated using the proximal maximum convexities (p = 0.002). Conclusions: The AALL is underestimated when the cusp tips are used as measurement reference points; the AALL can be measured more accurately using the proximal maximum convexities.

Seismic analysis of half-through steel truss arch bridge considering superstructure

  • Li, Ruiqi;Yuan, Xinzhe;Yuan, Wancheng;Dang, Xinzhi;Shen, Guoyu
    • Structural Engineering and Mechanics
    • /
    • 제59권3호
    • /
    • pp.387-401
    • /
    • 2016
  • This paper takes a half-through steel truss arch bridge as an example. A seismic analysis is conducted with nonlinear finite element method. Contrast models are established to discuss the effect of simplified method for main girder on the accuracy of the result. The influence of seismic wave direction and wave-passage on seismic behaviors are analysed as well as the superstructure and arch ring interaction which is mostly related with the supported bearings and wind resistant springs. In the end, the application of cable-sliding aseismic devices is discussed to put forward a layout principle. The main conclusions include: (1) The seismic response isn't too distinctive with the simplified method of main girder. Generally speaking, the grillage method is recommended. (2) Under seismic input from different directions, arch foot is usually the mostly dangerous section. (3) Vertical wave input and horizontal wave-passage greatly influence the seismic responses of arch ring, significantly increasing that of midspan. (4) The superstructure interaction has an obvious impact on the seismic performance. Half-through arch bridges with long spandrel columns fixed has a less response than those with short ones fixed. And a large stiffness of wind resistant spring makes the the seismic responses of arch ring larger. (5) A good isolation effectiveness for half-through arch bridge can be achieved by a reasonable arrangement of CSFABs.

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

Comparative analysis on digital models obtained by white light and blue LED optical scanners (백색광과 청색 LED 방식의 광학스캐너로 채득된 디지털 모형의 비교분석)

  • Choi, Seog-Soon;Kim, Jae-Hong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • 제36권1호
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze and compare the relative accuracy of digitized stone models of lower full arch, using two different scanning system. Methods: Replica stone models(N=20) were produced from lower arch acrylic model. Twenty digital models were made with the white light and blue LED($Medit^{(R)}$, Korea) scanner. Two-dimensional distance between the landmarks were measured on the Delcam $CopyCAD^{(R)}$(Delcam plc, UK). Independent samples t-test was applied for comparison of the groups. All statistical analyses were performed using the SPSS software package(Statistical Package for Social Sciences for Windows, version 12.0). Results: The absolute disagreement between measurements made directly on the two different scanner-based dental digital models was 0.02~0.04mm, and was not statistically significant(P>0.05). Conclusion: The precision of the blue LED optical scanner was comparable with the digitization device, and relative accuracy was similar. However, there still is room for improvement and further standardization of dental CAD technologies.

GROWTH AND DEVELOPMENT OF ARCH FORM (치열궁의 성장 변화)

  • Sohn, Byung-Wha;Baik, Hyoung-seon
    • The korean journal of orthodontics
    • /
    • 제28권1호
    • /
    • pp.17-27
    • /
    • 1998
  • Study on growth change of dental arch is considered to both an important data in orthodontic diagonsis and treatment planning as well as analysis of treatment results , also, arch form is important in anthropology and dentistry, even more so in prosthodontics and orthodontics. In the field of orthodontics, studies on the functional aspect of upper and lower teeth and maintenance of stability of dentition and occlusion were carried out from the early days. Some of the early studies include explanation of growth change in dental arch from measuring directly fom human stroll, and afterwards, cephalometrics x-rays were introduced; accordingly, studies using cephalometric measurement and linear measurements of study models were often performed. By this method, arch width, arch depth and perimeters were measured, and growth change or dental arch was studied. The subject ror this study were sn children(boys and girls or ages from 3 yens to 12 years from Kang-won district and Seoul, who has no history of orthodontic treatment and who show healthy status and normal growth and development. Cephalometric x-ray, panoramic x-ray, and study model were taken for each subject consecutively for 2 years, and the subjects are still followed up. 400 pairs of study models from the past two years were used in this study; mesio-distal diameater of each tooth, intercanine width, intermolar width, canine depth, molar depth and arch perimeters were measured. Afterwards, mean value and each standard deviation of each age group and each gender were obtained, and representation graph were drawn. The following conclusion were obtained. 1. Intercanine width showed gradual increase until the age of 10-years and after that, showed no increase. 2. Intermolar width in upper arch showed gradual increase : intermolar width in lower arch showed no significant chang, and after the age of 9-years, showed increase. 3. Cainine arch depth showed relatively rapid increase after the age of 6-years, and this pattern was more obvious in lower arch. 4. Molar arch depth increased gradually in both archs and it decrease after the age of 10-years : this phenomenon was more prominent in the lower arch. 5. Arch perimeter showed gradual inerease and convert to plateau at the age of 10-years, after that, it decreased. this pattern was more prominent in lower arch.

  • PDF

Three dimensional structural analysis between dental arch and basal bone in normal occlusion (정상교합자의 치열궁과 기저골 형태에 대한 3차원적 연구)

  • Kim, Jee-Tae;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • 제41권4호
    • /
    • pp.224-236
    • /
    • 2011
  • Objective: The purpose of this study was to analyze the dental and basal arch forms in patients with normal occlusion using the computed tomography (CT) imaging method. Methods: CT images were taken from 27 normal occlusion subjects (male, 15; female, 12) and these images were reconstructed into three-dimensional models. A 3D-coordinate system was formed by setting the middle of the facial axis (FA) point of the maxillary central incisors as the origin. The morphology of the maxilla and mandibular dental and basal arches were analyzed by sectioning parallel to the maxillary occlusal plane. Results: There was no significant difference between A point and B point and between the maxillary 1st molars in both sides of the maxillary and mandibular basal bone. The dental arch was located more labially than the basal arch in the anterior portion. The bucco-lingual crossover of the dental arch and basal arch was formed at the molar region in the maxilla, and at the premolar region in the mandible. Conclusions: This study will help provide three-dimensional diagnostic information about the relationship between basal and dental arches in patients who have severe dental compensation and inappropriate jaw relationships.