• 제목/요약/키워드: AR Method

검색결과 1,442건 처리시간 0.028초

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제12권7호
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

CE-QUAL-W2를 이용한 충주호의 기후변화에 따른 탁수 및 부영양화 영향평가 (Evaluation of Future Turbidity Water and Eutrophication in Chungju Lake by Climate Change Using CE-QUAL-W2)

  • 안소라;하림;윤성완;김성준
    • 한국수자원학회논문집
    • /
    • 제47권2호
    • /
    • pp.145-159
    • /
    • 2014
  • 본 연구에서는 충주댐을 대상으로 유역모델인 SWAT과 저수지모델인 CE-QUAL-W2를 연계 적용하여 기후변화에 따라 저수지로 유입되는 하천의 유량 및 탁수발생량을 모의하고, 저수지내의 탁수변화 및 부영양화 영향평가를 통한 저수지 수환경 변화를 전망하였다. 먼저 SWAT을 적용하여 강우시 저수지 유입하천의 유량 및 수질을 모의하여 모델의 재현성을 검토하였으며, 모형의 보정(2000~2005)과 검증(2006~2010) 결과 모델 예측값과 실측값이 적절하게 일치하는 것으로 나타났다. SWAT의 결과를 CE-QUAL-W2의 하천유량 및 유입수 수질경계조건 입력자료로 활용하고, 보정(2010년)과 검증(2008년)을 통하여 저수지 내 시간에 따른 물수지, 수온 변화, 부유물질(SS), T-N, T-P 및 부영양화(Chl-a) 양상 등을 분석하고 모델의 재현성을 검토하였다. 이후 기후변화 시나리오 적용에 따른 저수지 내수환경변화를 모의하기 위한 기후변화자료로 IPCC AR4 GCM(ECHO-G)을 고해상도지역 기후 시나리오로 개선시킨 RCM(MM5)의 A1B 시나리오를 다시 태풍사상을 고려한 인공신경망 기법에 의해 상세화하여 이용하였다. 기후변화 시나리오에 따른 기온증가의 영향으로 미래로 갈수록 상층수온은 증가하는 반면 심층수온은 감소하는 경향을 보였다. SS 최고유입농도는 평수년에 비해 풍수년에 17%, 갈수년에 0.2% 가량 증가하는 것으로 나타났다. 호소내 SS 10mg/L 이상 점유일수는 평수년에 비해 풍수년이 6일, 갈수년이 17일 증가하였고, 점유율 역시 풍수년에 24%, 갈수년에 26%가량 증가하는 것으로 분석되었다. 미래로 갈수록 기후변화가 충주댐 탁수장기화에 영향을 미치는 것으로 분석되었다. Chl-a의 최고농도는 평수년에 비해 풍수년에 19%, 갈수년에 3% 가량 조류의 농도가 증가되는 것으로 나타나 조류의 영향이 커지는 것을 알 수 있었다.

기후변화 시나리오를 활용한 미래 한반도 물수급 전망 (Water Balance Projection Using Climate Change Scenarios in the Korean Peninsula)

  • 김초롱;김영오;서승범;최수웅
    • 한국수자원학회논문집
    • /
    • 제46권8호
    • /
    • pp.807-819
    • /
    • 2013
  • 본 연구에서는 기존의 기후변화를 고려한 물수급 분석 방법론의 문제점을 개선하기 위해 GCM 미래 유량 시나리오를 물수급 모형에 직접 입력하는 대신 과거 유량 시나리오의 가중값(재현확률)을 부여하는 새로운 물수급 전망기법을 제안하고자 한다. GCM 미래 기후자료를 TANK 모형에 입력하여 중권역별 미래 유량을 모의하였으며 모의결과에 대한 편이보정을 위해 Quantile Mapping 기법을 적용하였다. 이러한 미래 유량 전망결과를 반영하여 각각의 입력자료에 대한 가중값(재현확률)을 새롭게 산정함으로써 미래 목표 전망구간에 대한 물부족량을 산정하였다. 물수급 모형의 입력자료에 대한 가중값 산정을 위해K-nn 알고리즘을 적용하였으며 비홍수기(10~6월) 유량을 가중값 산정을 위한 기준유량으로 결정하였다. 기후 변화의 불확실성을 고려하고자 4개의 GCM과 3개의 AR4 SRES 온실가스 배출 시나리오를 앙상블 조합하여 생성한 기후변화 시나리오를 활용하였다. 본 연구에서제시한 방법론을 한반도 4대강 유역에 적용한 결과, 기후변화를 고려한 한반도 미래 평균 물부족량은 2020s (2010~2039년)에는 과거에 비해 10~32% 정도 증가할 것으로 전망되었다. 또한, 한반도 4대강 유역의 경우 먼 미래로 갈수록 비홍수기 유량이 점차 감소할 것으로 전망됨에 따라 2080s (2070~2099년)에는 과거 대비 평균 물부족량이 최대 97%(약 516.5백만 $m^3$/년) 증가할 것으로 전망되었다. 기존의 기후변화 연구 방법론의 전망결과를 비교분석한 결과, 기존 방법론은 매우 극적인 물부족량 증가를 전망하고 있는 반면 본 연구에서 제안한 기법은 상대적으로 보수적인 변화를 전망하였다. 본 연구는 물수급 분석시기 후 변화를 고려하되 기존 국가계획 방법론의 틀을 최대한 유지하고 있다는 점에서 국가수자원계획 수립에 있어 정책결정권자들의 혼돈을 줄여줄 수 있는 방법론이 될 수 있다고 판단된다.

스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발 (Development of B4C Thin Films for Neutron Detection)

  • 임창휘;김종열;이수현;조상진;최영현;박종원;문명국
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.79-86
    • /
    • 2015
  • 헬륨-3는 높은 반응효율, 장시간 사용가능성, 감마선에 대한 낮은 반응확률 등과 같은 장점들을 가지고 있기 때문에 대부분의 중성자 검출기의 반응물질로 사용되어 왔다. 그러나 지난 몇 년 사이 전세계적인 헬륨-3의 부족으로 인해 기체의 수급이 어려워지고 있고 이에 따라 가격이 급격히 증가하게 되었다. 이러한 이유로 헬륨-3 대체 물질들을 이용한 고효율의 중성자 검출기의 개발에 대한 연구가 많은 연구그룹에 의해 활발히 진행되기 시작하였다. 이러한 연구에서는 다양한 물질들을 이용하고 있으며, 이 중에서 붕소-10은 다른 대체물질과 비교할 때 상대적으로 높은 중성자 반응확률, 낮은 감마반응효율, 물질의 안정성, 가격적 이점 그리고 기존 헬륨-3를 이용한 검출기의 계측회로의 재활용 가능성 등과 같은 장점들 때문에 많은 연구그룹에서 붕소-10을 이용한 중성자 검출기 개발을 진행하고 있다. 본 논문에서는 중성자 검출기에 사용될 수 있는 붕소-10 박막을 개발하고 이에 대한 성능평가를 수행하였다. 중성자 검출기의 반응물질로 붕소-10을 사용하기 위해서는 중성자와 붕소-10이 반응하여 생성되는 이차방사선을 측정할 수 있어야 한다. 본 연구에서 활용한 기체충진형 중성자 검출기의 경우 붕소-10을 얇은 박막 형태로 제작하여 중성자와 반응하여 생성된 이차방사선이 기체를 이온화 시켜서 생성되는 이온쌍을 측정하는 방법을 이용한다. 그러므로 중성자 반응효율과 이차방사선의 재흡수율을 고려한 붕소-10(탄화붕소)의 적절한 두께를 선정할 필요가 있다. 이를 위해서 본 논문에서는 몬테칼로 기법을 이용하는 MCNP6를 이용하여 다양한 두께에 따른 중성자신호수집효율의 변화를 계산하였다. 또한, 스퍼터링 기법을 이용하여 다양한 두께의 박막을 제작하고 이를 이용하여 중성자 반응신호를 측정하였다. 그리고 제작된 박막의 2차원 모니터링을 위한 다중선 비례계수기의 적용가능성을 타진하기 위해 제작된 붕소박막이 설치된 2차원 다중선 비례계수기를 제작하고 중성자 응답 특성을 평가하였다.

연탄재를 시멘트로서 경화(硬化)시켰을 때의 강도(强度)에 관(關)한 연구(硏究) (Studies on the Strength of Briquette Ash Hardened by Cement)

  • 김성완
    • 농업과학연구
    • /
    • 제6권1호
    • /
    • pp.45-55
    • /
    • 1979
  • 본연구(本硏究)는 연탄재를 시멘트로 경화(硬化)시켰을때의 강도(强度)에 관(關)한 연구(硏究)를 위하여 시멘트:연탄재, [시멘트(90%)+소석회(消石灰)(10%)]:연탄재, [시멘트(80%)+프라이애쉬(20%)]:연탄재, 시멘트:표준사(標準砂)의 4종(種)을 각각(各各) 배합비(配合比) 1:2, 1:3, 1:4, 1:5, 1:7, 1:9의 6종(種)으로 분류(分類)하고 압축(壓縮), 인장(引張), 휨강도시험(强度試驗)을 재령(材令) 7일(日) 및 28일(日)로 구분(區分)하여 시험(試驗)하였다. 본시험(本試驗) 이외(以外)에 경제성(經濟性)의 검토(檢討), 내구성시험(耐久性試驗)등 구명(究明)하여야 할 문제(問題)가 남겨져 있으나 본시험(本試驗)에서 얻은 결과(結果)를 요약(要約)하면 다음과 같다. 1. 압축강도(壓縮强度)는 KS 규격치(規格値)에 대하여 1:2의 재령(材令) 7일(日)에서 시멘트:연탄재는 84%, (시멘트+소석회(消石灰)):연탄재는 90%, (시멘트+프라이애쉬):연탄재는 75%의 강도(强度)를 나타냈고 재령(材令) 28일(日)에서 시멘트:연탄재는 84.9%, (시멘트+소석회(消石灰)):연탄재는 73.5%, (시멘트+프라이애쉬):연탄재는 69.8%의 강도(强度)가 나타났다. 2. 압축강도(壓縮强度)는 표준사(標準砂)를 사용(使用)한 모르터의 강도(强度)를 100%로 했을때 1:2의 재령(材令) 7일(日)에서 시멘트:연탄재는 69.3%, (시멘트+소석회(消石灰)):연탄재는 75.1%, (시멘트+프라이애쉬):연탄재는 41.3%의 강도(强度)가 나타났으며 재령(材令) 28일(日)에서는 전자(前者)와 동일순(同一順)으로 56.4%, 49%, 46.5%의 강도(强度)를 나타냈다. 3. 인장강도(引張强度)는 표준사(標準砂)를 사용(使用)한 모르터의 인장강도(引張强度)를 100%로 했을때 1:2의 재령(材令) 7일(日)에서 시멘트:연탄재는 64.4%, (시멘트+소석회(消石灰)):연탄재는 47.1%, (시멘트+프라이애쉬):연탄재는 35.4%의 강도(强度)를 나타냈으며 재령(材令) 28일(日)에서는 전자(前者)와 동일순(同一順)으로 69.6%, 64.8%, 57.3%의 강도(强度)를 나타냈다. 4. 휨강도(强度)는 표준사(標準砂)를 사용(使用)한 모르터의 강도(强度)를 100%로 했을때 1:2의 재령(材令) 7일(日)에서 시멘트:연탄재는 46.3%, (시멘트+소석회(消石灰)):연탄재는 65.9%, (시멘트+프라이애쉬):연탄재는 39.1%의 강도(强度)를 나타냈으며 재령(材令) 28일(日)에서는 전자(前者)와 동일순(同一順)으로 89.9%, 96.7%, 85.1%의 강도(强度)를 나타냈다. 5. 연탄재를 시멘트로 경화(硬化)시켰을 때의 강도(强度)는 시멘트 모르터에 비(比)해서 저강도(低强度)이지만 시멘트 또는 콘크리트 2차제품(次製品)에 이용(利用)이 가능(可能)하다고 보며 연탄재를 경화(硬化)시켜 건설재료(建設材料)로 이용(利用)하므로서 각종(各種) 공해방지(公害防止)와 폐기물처리(廢棄物處理)의 노력절약(努力節約)과 폐기물(廢棄物)의 유효이용(有效利用)으로 골재자원(骨材資源)의 절약(節約)에 유익(有益)하다고 생각된다.

  • PDF

(NiFe/CoFe)/Cu/CoFe Spin-Valve 박막의 자기저항 특성 (Magnetoresistive of (NiFe/CoFe)/Cu/CoFe Spin-Valvec)

  • 오미영;이선영;이정미;김미양;이장로
    • 한국자기학회지
    • /
    • 제7권5호
    • /
    • pp.265-273
    • /
    • 1997
  • 연자성 자유자성층과 피속박자성층을 각각 2중층 Ni$_{81}$fe$_{19}$/ $Co_{90}$ Fe$_{10}$$Co_{90}$ Fe$_{10}$로 하고, 반강자성 속박층을 NiO로 하는 NiFe/CoFe/Cu/CuFe/NiO 구조를 갖는 spin-valve 박막을 sputtering 방법으로 유리기판위에 제작하고, 자기저항비(MR), 자기장감응도(field sensitivity), 반강자성층과 피속박자성층사이의 교환결합 자기장(exchange coupling field), 자유자성층과 피속박자성층사이의 층간결합자기장(interlayer coupling field) 등의 비자성 사이층 Cu 두께, 자유자성층두께, 피속박자성층 두께 및 반강자성층 두께 의존성을 조사하였다. 2중층 자유자성층에 연자성 NiFe가 20 .angs. 이상 포함됨으로써 10 Oe의 보자력을 가져 연자성특성을 향상시키는 것을 확인할 수 있었다. Cu의 두께가 30 .angs. 일 때 극대 MR비를 가졌으며 두께증가에 따라 감소하는 경향을 보였다. 피속박자성층 CoFe의 두께가 35 .angs. 일 때 그대 MR비 6.3%를 나타내며 두께증가에 따라 감소하며 교환결합자기장도 CoFe 두께가 증가함에 따라 감소하였다. NiO 두께가 800 .angs. 일 때 극대 MR비를 보이며 교환결합자기장은 두께증가에 따라 50 Oe 정도로 포화되어 NiO가 반강자성 특성을 유지하기 위해서는 일정한 두께이상이 되어야 함을 알 수 있었다. 열처리온도 200 .deg. C 까지는 MR비 5.3%를 유지하다 이보다 높하지면 점점 감소하여 300 .deg. C에서도 약 3% 정도를 유지하여 열적 안정성이 향상되었다. 따라서 CoFe 합금을 사용하여 NiFe(40 .angs. )/CoFe(50 .angs. )/Cu(30 .angs. )/CoFe(35 .angs. )/NiO(800 .angs. ) 구조를 갖는 spin-valve 박막은 극대 MR비 6.3%, 유효자기장감응도 약 0.5(%/Oe)를 보여 spin-valve head 재료로 적합함을 알 수 있었다.다.다.다.

  • PDF

동맥전환술을 시행한 대혈관전위 환자에서 심초음파를 이용한 술후 추적 (Echocardiographic Follow-up after Arterial Switch Operation for Transposition of the Great Arteries)

  • 한승세;정태은;이동협;오정훈;이정철
    • Journal of Chest Surgery
    • /
    • 제34권10호
    • /
    • pp.754-762
    • /
    • 2001
  • 배경: 영낡치대 흥부외과학교실에서 1989년부터 1998년 사이에 대혈관전위로 동맥전환술을 받고 6개월 이상 추적관찰한 환자 8례를 대상으로, 동맥 전환술의 효용도를 평가하기 위해 반복적인 심초음파 검사를 시행한 후 그 자료를 후향적으로 분석하였다. 대상 및 방법: 추적관찰기간은 평균 4.1년이었고 최단 6개월에서 최장 11년이었다. 대성환자의 연령은 평균 29일(범위 3∼56일)이었고 체중은 평균 3.6kg(범위 2.6∼4.8kg)이었다. 술 전 진단은 TGA+VSD가 5례, TGA+IVS가 3례이었다. 좌심실 shortening fraction, 좌심실 수축기 시간간격(left ventricle systolic time interval, LVSTI), 우심실 수축기 시간간격(right ventricle systolic time interval, RVSTI), 그리고 좌심실구축률(EF)을 측정하여 좌심실의 기능을 평가하였다. 대동맥과 폐동맥의 최고 수축기압차 속도 (peak systolic pressure gradient velocity, PSPGV), 판막의 폐쇄부전상태, 좌심방/대동맥비(LA/Ao ratio), 대동맥과 폐동맥 근부의 크기, 등을 정상치와 비교하여 판막의 기능과 대혈관의 성장을 평가하였다. 결과: 좌심실구축률은 평균 65.0+9.03%이었으며 추적관찰 동안 시간이 경가함에 따라 대체로 증가하는 경향을 보였다. 좌심실상행대동맥압차는 평균 15.9mmHg이었고 우심실폐동맥압차는 평균 27.5mmHg이었다. 수축기말 대동맥근부 크기(aortic root dimension at end-systole)는 8례 중 6례에서 동일 연령군의 정상발육 평균치보다 발육이 증가하는 양상이었고 발육과정에 따라 증가하는 양상을 보였다. 수축기말 폐동맥 근부 크기(PA root dimension at end-systole)는 동일연령군의 정상발육 평균치와 비교할 때 비슷한 성장경과를 보였다. 술후 판막 폐쇄부전의 변동을 보면 폐동맥판막폐쇄부전은 8례 중 5례에서 있었고 1례에서 2도이었고 그 외는 1도 이하이었다. 대동맥판막폐쇄부전은 8례 중 술전 0도에서 술후 1도로 변동한 경우가 6례였다. 이상과 간이 폐쇄부전이 있더라도 대부분 1도 이하이었기 때문에 인상적인 의의는 없었다

  • PDF

농업분야 활용을 위한 한반도 1km 격자형 SSP 기후변화 시나리오 (SSP Climate Change Scenarios with 1km Resolution Over Korean Peninsula for Agricultural Uses)

  • 허지나;조재필;조세라;심교문;김용석;강민구;오찬성;서승범;김응섭
    • 한국농림기상학회지
    • /
    • 제26권1호
    • /
    • pp.1-30
    • /
    • 2024
  • 국제사회는 IPCC를 중심으로 SSP (Shared Socioeconomic Pathways) 기후변화 시나리오를 새로운 온실가스 변화 경로로 채택하고, 신기후변화 시나리오 기반으로 다양한 규모와 형태로 기후변화를 전망하고 분석하고 있다. 국립농업과학원은 이러한 국제적 동향을 반영하고 농업부문 기후변화 적응대책 지원을 위한 노력의 일환으로 신규 온실가스 경로에 기반한 한반도 상세(1km) 기후변화 시나리오를 산출하였다. 본 논문은 2022년 "국가 기후변화 표준 시나리오" 로 인증받은 국립농업과학원의 SSP 기후변화 시나리오 자료를 소개하고, 기후변화 전망 결과를 보여주고자 한다. 한반도의 미래 기후 변화에 대한 전망 정보를 생산하기 위해 CMIP6에 참여한 18개의 GCM 모형에서 생산된 전지구 규모의 기후 자료를 과거기간(1985-2014)과 미래기간(2015-2100)에 대해 수집하고, 1km 격자형 한반도 전자기후도와 SQM 방법을 이용하여 한반도 영역에 대해 통계적 상세화를 수행하였다. 21세기 후반기(2071~2100년), 한반도의 연평균 최고, 최저기온은 온실가스 배출 정도에 따라 각각 2.6~6.1 ℃, 2.5~6.3 ℃ 상승하고, 연강수량은 21.5~38.7 % 상승하는 것으로 전망되었다. 저탄소 시나리오(SSP1-2.6)의 경우 기온과 강수량 상승이 적게 나타나, 탄소 배출을 감축하는 경우에 상승 폭을 억제할 수 있을 것으로 전망되었다. 21세기 후반기의 우리나라 평균 풍속과 일사량은 상대적으로 현재 대비 미래에 큰 변화가 없을 것으로 전망하고 있다. 이 자료는 기후변화에 따를 미래의 불확실성을 이해하고 기후변화 적응을 위한 합리적인 의사결정에 기여할 수 있을 것으로 기대된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF