• Title/Summary/Keyword: APs

Search Result 1,785, Processing Time 0.023 seconds

Resurfacing the donor sites of reverse sural artery flaps using thoracodorsal artery perforator flaps

  • Oh, Se Won;Park, Seong Oh;Kim, Youn Hwan
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.691-698
    • /
    • 2021
  • Background The reverse sural artery (RSA) flap is widely used for lower extremity reconstruction. However, patients sometimes suffer from donor site complications such as scar contracture and paresthesia, resulting in dissatisfaction with the aesthetic outcomes. This study investigated the characteristics of donor site morbidity associated with RSA flaps and described our experiences of dealing with complications by performing resurfacing surgery using thoracodorsal artery perforator (TDAP) flaps. Methods From April 2008 to August 2018, a total of 11 patients underwent contracture release and resurfacing surgery using TDAP flaps due to donor morbidity associated with RSA flaps. All affected donor sites were covered with a skin graft, the most common of which was a meshed split-thickness skin graft (six cases). Results Eight of the 11 patients (72.7%) suffered from pain and discomfort due to scar contracture, and seven (63.6%) complained of a depression scar. The donor sites were located 6.3±4.1 cm below the knee joint, and their average size was 140.1 cm2. After resurfacing using TDAP flaps, significant improvements were found in the Lower Extremity Functional Scale (LEFS) scores and the active and passive ranges of motion (AROM and PROM) of the knee joint. The LEFS scores increased from 45.1 to 56.7 postoperatively (P=0.003), AROM increased from 108.2° to 118.6° (P=0.003), and PROM from 121.4° to 126.4° (P=0.021). Conclusions Planning of RSA flaps should take into account donor site morbidity. If complications occur at the donor site, resurfacing surgery using TDAP flaps achieves aesthetic and functional improvements.

Fingertip reconstruction with a subcutaneous flap and composite graft composed of nail bed and volar pulp skin

  • Koh, Sung Hoon;Park, Ilou;Kim, Jin Soo;Lee, Dong Chul;Roh, Si Young;Lee, Kyung Jin;Hong, Min Ki
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.70-75
    • /
    • 2022
  • Background Fingertip injuries are very common; however, the reconstruction of volar pulp defects with nail bed defects is challenging in the absence of the amputated segment. We reconstructed fingertip amputations with nail bed defects using a new surgical approach: a subcutaneous flap and composite graft. Methods We treated 10 fingertip amputation patients without an amputated segment, with exposed distal phalangeal bone and full-thickness nail bed defects between February 2018 and December 2020. All patients underwent two-stage surgery: in the first stage, a subcutaneous flap was performed to cover the exposed distal phalanx, and in the second stage, a composite graft, consisting of nail bed, hyponychium, and volar pulp skin, was applied over the subcutaneous flap. Results All flaps survived and all composite grafts were successful. The wounds healed without any significant complications, including the donor site. The average follow-up duration was 11.2 months (range, 3-27 months). The new nail and the shape of the volar pulp were evaluated during follow-up. All patients were satisfied with their natural fingertip shapes and the new nails did not have any serious deformities. Conclusions A subcutaneous flap in combination with a composite graft fitting the shape of the defect could be another option for fingertip injuries without amputated segments.

Transcutaneous medial fixation sutures for free flap inset after robot-assisted nipple-sparing mastectomy

  • Kim, Bong-Sung;Kuo, Wen-Ling;Cheong, David Chon-Fok;Lindenblatt, Nicole;Huang, Jung-Ju
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.29-33
    • /
    • 2022
  • The application of minimal invasive mastectomy has allowed surgeons to perform nipples-paring mastectomy via a shorter, inconspicuous incision under clear vision and with more precise hemostasis. However, it poses new challenges in microsurgical breast reconstruction, such as vascular anastomosis and flap insetting, which are considerably more difficult to perform through the shorter incision on the lateral breast border. We propose an innovative technique of transcutaneous medial fixation sutures to help in flap insetting and creating and maintaining the medial breast border. The sutures are placed after mastectomy and before flap transfer. Three 4-0 nylon suture loops are placed transcutaneously and into the pocket at the markings of the preferred lower medial border of the reconstructed breast. After microvascular anastomosis and temporary shaping of the flap on top of the mastectomy skin, the three corresponding points for the sutures are identified. The three nylon loops are then sutured to the dermis of the corresponding medial point of the flap. The flap is placed into the pocket by a simultaneous gentle pull on the three sutures and a combined lateral push. The stitches are then tied and buried after completion of flap inset.

Wall shear stress on vascular smooth muscle cells exerts angiogenic effects on extracranial arteriovenous malformations

  • Ryu, Jeong Yeop;Park, Tae Hyun;Lee, Joon Seok;Oh, Eun Jung;Kim, Hyun Mi;Lee, Seok-Jong;Lee, Jongmin;Lee, Sang Yub;Huh, Seung;Kim, Ji Yoon;Im, Saewon;Chung, Ho Yun
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.115-120
    • /
    • 2022
  • Background In addition to vascular endothelial cells, vascular smooth muscle cells (VSMCs) are subject to continuous shear stress because of blood circulation. The angiogenic properties of VSMCs in extracranial arteriovenous malformations (AVMs) may exceed those of normal blood vessels if the body responds more sensitively to mechanical stimuli. This study was performed to investigate the hypothesis that rapid angiogenesis may be achieved by mechanical shear stress. Methods VSMCs were obtained from six patients who had AVMs and six normal controls. The target genes were set to angiopoietin-2 (AGP2), aquaporin-1 (AQP1), and transforming growth factor-beta receptor 1 (TGFBR1). Reverse-transcriptase polymerase chain reaction (RT-PCR) and real-time PCR were implemented to identify the expression levels for target genes. Immunofluorescence was also conducted. Results Under the shear stress condition, mean relative quantity values of AGP2, AQP1, and TGFBR1 in AVM tissues were 1.927±0.528, 1.291±0.031, and 2.284±1.461 when compared with neutral conditions. The expression levels of all three genes in AVMs were higher than those in normal tissue except for AQP1 under shear stress conditions. Immunofluorescence also revealed increased staining of shear stress-induced genes in the normal tissue and in AVM tissue. Conclusions Shear stress made the VSMCs of AVMs more sensitive. Although the pathogenesis of AVMs remains unclear, our study showed that biomechanical stimulation imposed by shear stress may aggravate angiogenesis in AVMs.

A comparison of using a smartphone versus a surgical microscope for microsurgical anastomosis in a non-living model

  • Jianmongkol, Surut;Vinitpairot, Chaiyos;Thitiworakarn, Navapong;Wattanakamolchai, Settapon
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.121-126
    • /
    • 2022
  • Background Although they may not replace standard training methods that use surgical microscopes, smartphones equipped with high-resolution screens and high-definition cameras are an attractive alternative for practicing microsurgical skills. They are ubiquitous, simple to operate, and inexpensive. This study compared anastomoses of chicken femoral vessels using a smartphone camera versus a standard operative microscope. Methods Forty anastomoses of non-living chicken femoral vessels were divided into four groups. A resident and an experienced microsurgeon performed anastomoses of femoral chicken vessels with 8-0 and 10-0 sutures, using a smartphone camera and a surgical microscope. The time to complete the anastomosis and the number of anastomosis errors were compared using the Mann-Whitney U test. Results The time taken to perform an anastomosis by the experienced microsurgeon was significantly longer when using the smartphone (median: 32.5 minutes vs. 20 minutes, P<0.001). The resident completed the anastomoses with both types of equipment without a significant difference in the operative times. When using a smartphone, the operation times were not significantly different between the resident and the experienced microsurgeon (P=0.238). The resident showed non-significant differences in operation time and the number of errors when using a smartphone or an operative microscope (P=1.000 and P=0.065, respectively). Conclusions Microsurgical practice with non-living chicken femoral vessels can be performed with a smartphone, though it can take longer than with an operative microscope for experienced microsurgeons. The resident may also experience frustration and tend to make more anastomosis errors when using a smartphone versus an operative microscope.

Division of a single free flap in multiple digit reconstruction

  • Kim, Jin Soo;Song, Cheon Ho;Roh, Si Young;Koh, Sung Hoon;Lee, Dong Chul;Lee, Kyung Jin
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.61-69
    • /
    • 2022
  • Background Single free flaps are a commonly used reconstructive method for multiple soft tissue defects in digits. We analyzed the flap size, division timing, and degree of necrosis in cases with various types of flap division. Methods We conducted a retrospective review of the medical charts of patients who had undergone single free flap reconstruction for multiple soft tissue defects across their digits from 2011 to 2020. The flap types included were the lateral arm free flap, venous forearm free flap, thenar free flap, hypothenar free flap, anterolateral thigh free flap, medial plantar free flap, and second toe pulp free flap. Flap size, anastomosed vessels, division timing, and occurrence of flap necrosis were retrospectively investigated and then analyzed using the t-test. Results In total, 75 patients were included in the analysis. The success rate of the free flaps was 97.3%. All flaps were successfully divided after at least 17 days, with a mean of 47.17 days (range, 17-243 days) for large flaps and 42.81 days (range, 20-130 days) for the medium and small flaps (P=0.596). The mean area of flap necrosis was 2.38% in the large flaps and 2.58% in the medium and small flaps (P=0.935). Severe necrosis of the divided flap developed in two patients who had undergone flap division at week 6 and week 34. Conclusions In cases where blood flow to the flap has been stable for more than 3 weeks, flap division can be safely attempted regardless of the flap size.

Clinical and preclinical tolerance protocols for vascularized composite allograft transplantation

  • Yang, Jerry Huanda;Johnson, Ariel C.;Colakoglu, Salih;Huang, Christene A.;Mathes, David Woodbridge
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.703-713
    • /
    • 2021
  • The field of vascularized composite allografts (VCAs) has undergone significant advancement in recent decades, and VCAs are increasingly common and accepted in the clinical setting, bringing hope of functional recovery to patients with debilitating injuries. A major obstacle facing the widespread application of VCAs is the side effect profile associated with the current immunosuppressive regimen, which can cause a wide array of complications such as infection, malignancy, and even death. Significant concerns remain regarding whether the treatment outweighs the risk. The potential solution to this dilemma would be achieving VCA tolerance, which would allow recipients to receive allografts without significant immunosuppression and its sequelae. Promising tolerance protocols are being studied in kidney transplantation; four major trials have attempted to withdraw immunosuppressive treatment with various successes. The common theme in all four trials is the use of radiation treatment and donor cell transplantation. The knowledge gained from these trials can provide valuable insight into the development of a VCA tolerance protocol. Despite similarities, VCAs present additional barriers compared to kidney allografts regarding tolerance induction. VCA donors are likely to be deceased, which limits the time for significant pre-conditioning. VCA donors are also more likely to be human leukocyte antigen-mismatched, which means that tolerance must be induced across major immunological barriers. This review also explores adjunct therapies studied in large animal models that could be the missing element in establishing a safe and stable tolerance induction method.

Excisional lipectomy versus liposuction in HIV-associated lipodystrophy

  • Barton, Natalie;Moore, Ryan;Prasad, Karthik;Evans, Gregory
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.685-690
    • /
    • 2021
  • Background Human immunodeficiency virus (HIV)-associated lipodystrophy is a known consequence of long-term highly active antiretroviral therapy (HAART). However, a significant number of patients on HAART therapy were left with the stigmata of complications, including fat redistribution. Few studies have described the successful removal of focal areas of lipohypertrophy with successful outcomes. This manuscript reviews the outcomes of excisional lipectomy versus liposuction for HIV-associated cervicodorsal lipodystrophy. Methods We performed a 15-year retrospective review of HIV-positive patients with lipodystrophy. Patients were identified by query of secure operative logs. Data collected included demographics, medications, comorbidities, duration of HIV, surgical intervention type, pertinent laboratory values, and the amount of tissue removed. Results Nine male patients with HIV-associated lipodystrophy underwent a total of 17 procedures. Of the patients who underwent liposuction initially (n=5), 60% (n=3) experienced a recurrence. There were a total of three cases of primary liposuction followed by excisional lipectomy. One hundred percent of these cases were noted to have a recurrence postoperatively, and there was one case of seroma formation. Of the subjects who underwent excisional lipectomy (n=4), there were no documented recurrences; however, one patient's postoperative course was complicated by seroma formation. Conclusions HIV-associated lipodystrophy is a disfiguring complication of HAART therapy with significant morbidity. Given the limitations of liposuction alone as the primary intervention, excisional lipectomy is recommended as the primary treatment. Liposuction may be used for better contouring and for subsequent procedures. While there is a slightly higher risk for complications, adjunctive techniques such as quilting sutures and placement of drains may be used in conjunction with excisional lipectomy.

Reconstruction of congenital microtia after ear canaloplasty using V-Y advancement of a temporal triangular flap

  • Park, Hae Yeon;Lee, Kyeong-Tae;Kim, Eun-Ji;Oh, Kap Sung
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.614-621
    • /
    • 2021
  • Background Reconstruction of congenital microtia remains challenging, particularly in patients with a history of ear canaloplasty due to insufficient regional soft tissue. The insertion of a tissue expander prior to implantation of the cartilage framework has traditionally been employed. However, this procedure could induce additional morbidity. Herein, we present a method using V-Y advancement of a temporal triangular flap to gain additional soft tissue in these challenging cases. Methods Congenital microtia patients with a history of ear canaloplasty who underwent auricular reconstruction using the Nagata technique between 2016 and 2020 were reviewed. To obtain additional soft tissue, V-Y advancement of a temporal triangular flap was performed concurrently with implantation of the costal cartilage framework, without prior insertion of a tissue expander. The outcomes of these patients with respect to postoperative complications and esthetics were evaluated. Results Eight patients with bilateral lesions were included. No specific complications developed after the first-stage surgery. However, one patient experienced complications after the second stage (auricular elevation). An analysis of the esthetic results showed most patients had excellent outcomes, achieving a satisfactory convolution. The median number of operations needed to complete reconstruction was 2, which was fewer than required using the conventional method with prior insertion of a tissue expander. Conclusions In patients with a history of previous canaloplasty, V-Y advancement of a temporal triangular flap could serve as an alternative to tissue expansion for microtia reconstruction. This technique provided reliable and satisfactory results with a reduced number of surgical stages.

Secondary nipple reconstruction using two surgical techniques

  • Chung, Jae-Ho;Kim, Da-Som;Yeo, Hyun-Dong;Jung, Seung-Pil;Park, Seung-Ha;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.590-598
    • /
    • 2021
  • Background Although the initial projection after primary nipple reconstruction is excellent, nipple projection gradually flattens in most cases due to multiple causes. Although various methods have been reported to rebuild the nipple after nipple flattening, the most effective method of secondary nipple reconstruction remains unknown. The aim of this study was to review our institution's experiences with secondary nipple reconstruction. Methods We conducted a retrospective review from March 2012 to January 2019. We performed secondary nipple reconstruction if the primary reconstructed nipple height differed by more than 6 mm from the normal nipple height. We chose the method of nipple revision according to the degree of tissue scarring and the remaining nipple projection. Results We performed secondary nipple reconstruction on a total of 27 nipples, using purse-string sutures for 19 nipples and star flaps in eight nipples. The median follow-up period was 8 months (range, 6-19 months) after the final nipple reconstruction. Among the 19 nipples reconstructed using purse-string sutures, 10 (53%) demonstrated acceptable projection of more than 5 mm. Among the eight nipples reconstructed using star flaps, six (75%) showed acceptable projection of more than 5 mm. Most of the patients (73%) were satisfied (scores of 4 or 5) with the nipple reconstruction overall. Conclusions Few studies have presented favorable outcomes of secondary nipple reconstruction. When the star flap and purse-string suture methods were used depending on the remaining nipple height and scarring, appropriate projection could be achieved.