• 제목/요약/키워드: APOLLO3

검색결과 31건 처리시간 0.038초

Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System

  • Goenka, Mahesh Kumar;Shah, Bhavik Bharat;Rai, Vijay Kumar;Jajodia, Surabhi;Goenka, Usha
    • Clinical Endoscopy
    • /
    • 제51권6호
    • /
    • pp.563-569
    • /
    • 2018
  • Background/Aims: To evaluate patients with portal hypertension (PH) of varied etiologies for portal hypertensive enteropathy (PHE) using the PillCam SB3 capsule endoscopy (CE) system. Methods: Consecutive patients with PH presenting with unexplained anemia and/or occult gastrointestinal bleeding were evaluated using the PillCam SB3 CE system. Abnormal findings were categorized as vascular or non-vascular. The patients with ongoing bleeding caused by PHE were treated. The correlation of the CE scores of PHE with the clinical, laboratory, and endoscopic features was determined. Results: Of the 43 patients included in the study, 41 (95.3%) showed PHE findings. These included varices (67.4%), red spots (60.5%), erythema (44.2%), villous edema (46.5%), telangiectasia (16.3%), and polyps (16.3%). The CE scores varied from 0 to 8 ($mean{\pm}standard$ deviation, $4.09{\pm}1.8$). Five patients (11.6%) showed evidence of ongoing or recent bleeding due to PHE. Three of these five patients underwent endotherapy, and one patient underwent radiological coil placement. Conclusions: The PillCam SB3 CE system revealed a high prevalence of PHE in the patients with PH. Using this system, evidence of bleeding due to PHE was found in a small but definite proportion of the patients.

HP/Apollo의 퍼스널 수퍼워크스테이션 DN

  • 양금엽
    • 전산구조공학
    • /
    • 제3권4호
    • /
    • pp.29-34
    • /
    • 1990
  • HP의 HP/Apollo시리즈 10000 TX(Visualization System)는 고성능 RISC그래픽을 사용한 최초의 워크스테이션으로서, 아폴로의 Multiprocessing PRISM 아키텍쳐와 강력한 3D 그래픽 엔진을 채택하고 있어, 시스템의 성능과 Image Quality, Openness 및 Flexibility를 높여줌으로써, 타 제품에 비해 탁월한 성능과 기능을 제공하고 있으며, 사용자의 투자에 대한 효과를 확실히 높여주고 있다.

  • PDF

A prospective study of fully covered self-expandable metal stents for refractory benign pancreatic duct strictures

  • Bhavik Bharat Shah;Gajanan Ashokrao Rodge;Usha Goenka;Shivaraj Afzalpurkar;Mahesh Kumar Goenka
    • Clinical Endoscopy
    • /
    • 제55권6호
    • /
    • pp.793-800
    • /
    • 2022
  • Background/Aims: Fully covered self-expanding metal stents (FCSEMSs) are a relatively novel option for treating painful main pancreatic duct refractory strictures in patients with chronic pancreatitis. Herein, we aimed to assess the efficacy, feasibility, and safety of FCSEMSs in this patient group. Methods: This prospective single-center study included patients who underwent endoscopic retrograde pancreatography with FCSEMS placement. The primary endpoints were the technical and clinical success rates. A reduction in visual analog scale pain score of >50% compared with that before stent placement was defined as clinical success. Secondary endpoints were resolution of pancreatic strictures on fluoroscopy during endoscopic retrograde pancreatography and the development of stent-related adverse events. Results: Thirty-six patients were included in the analysis. The technical success rate was 100% (n=36) and the clinical success rate was 86.1% (n=31). There was a significant increase in stricture diameter from 1.7 mm to 3.5 mm (p<0.001) after stent removal. The mean visual analog scale pain score showed statistically significant improvement. At 19 months of follow-up, 55.6% of the patients were asymptomatic. Stent migration (16.7%), intolerable abdominal pain (8.3%), development of de novo strictures (8.3%), and mild pancreatitis (2.8%) were the most common adverse events. Conclusions: FCSEMS placement showed good technical and clinical success rates for achieving pain relief in patients with refractory main pancreatic duct strictures.

Laparoscopic cholecystectomy for acute cholecystitis: Any time is a good time

  • Hamza Wani;Sadananda Meher;Uppalapati Srinivasulu;Laxmi Narayanan Mohanty;Madhusudan Modi;Mohammad Ibrarullah
    • 한국간담췌외과학회지
    • /
    • 제27권3호
    • /
    • pp.271-276
    • /
    • 2023
  • Backgrounds/Aims: Laparoscopic cholecystectomy within one week of acute cholecystitis is considered safe and advantageous. Surgery beyond first week is reserved for non-resolving attack or complications. To compare clinical outcomes of patients undergoing laparoscopic cholecystectomy in the first week and between two to six weeks of an attack of acute cholecystitis. Methods: In an analysis of a prospectively maintained database, all patients who underwent laparoscopic cholecystectomy for acute cholecystitis were divided into two groups: group A, operated within one week; and group B, operated between two to six weeks of an attack. Main variables studied were mean operative time, conversion to open cholecystectomy, morbidity profile, and duration of hospital stay. Results: A total of 116 patients (74 in group A and 42 in group B) were included. Mean interval between onset of symptoms & surgery was five days (range, 1-7 days) in group A and 12 days (range, 8-20 days) in group B. Operative time and incidence of subtotal cholecystectomy were higher in group B (statistically not significant). Mean postoperative stay was 2 days in group A and 3 days in group B. Laparoscopy was converted to open cholecystectomy in two patients in each group. There was no incidence of biliary injury. One patient in group B died during the postoperative period due to continued sepsis and multiorgan failure. Conclusions: In tertiary care setting, with adequate surgical expertise, laparoscopic cholecystectomy can be safely performed in patients with acute cholecystitis irrespective of the time of presentation.

APOLLO3 homogenization techniques for transport core calculations-application to the ASTRID CFV core

  • Vidal, Jean-Francois;Archier, Pascal;Faure, Bastien;Jouault, Valentin;Palau, Jean-Marc;Pascal, Vincent;Rimpault, Gerald;Auffret, Fabien;Graziano, Laurent;Masiello, Emiliano;Santandrea, Simone
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1379-1387
    • /
    • 2017
  • This paper presents a comparison of homogenization techniques implemented in the APOLLO3 platform for transport core calculations: standard scalar flux weighting and new flux-moment homogenization, in different combinations with (or without) leakage models. Besides the historical B1-homogeneous model, a new B-heterogeneous one has indeed been implemented recently in the two/three-dimensional-transport solver using the method of characteristics. First analyses have been performed on a very simple Sodium Fast Reactor core with a regular hexagonal lattice. They show that using the heterogeneous leakage model in association with flux-moment homogenization strongly improves the prediction of $k_{eff}$ and void reactivity effects. These good results are confirmed when the application is done to the fissile assemblies of the more complex CFV (Low Void Effect) core of the ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) project of sodium-cooled fast breeder reactor (Generation IV).

A new Tone's method in APOLLO3® and its application to fast and thermal reactor calculations

  • Mao, Li;Zmijarevic, Igor
    • Nuclear Engineering and Technology
    • /
    • 제49권6호
    • /
    • pp.1269-1286
    • /
    • 2017
  • This paper presents a newly developed resonance self-shielding method based on Tone's method in $APOLLO3^{(R)}$ for fast and thermal reactor calculations. The new method is based on simplified models, the narrow resonance approximation for the slowing down source and Tone's approximation for group collision probability matrix. It utilizes mathematical probability tables as quadrature formulas in calculating effective cross-sections. Numerical results for the ZPPR drawer calculations in 1,968 groups show that, in the case of the double-column fuel drawer, Tone's method gives equivalent precision to the subgroup method while markedly reducing the total number of collision probability matrix calculations and hence the central processing unit time. In the case of a single-column fuel drawer with the presence of a uranium metal material, Tone's method obtains less precise results than those of the subgroup method due to less precise heterogeneous-homogeneous equivalence. The same options are also applied to PWR UOX, MOX, and Gd cells using the SHEM 361-group library, with the objective of analyzing whether this energy mesh might be suitable for the application of this methodology to thermal systems. The numerical results show that comparable precision is reached with both Tone's and the subgroup methods, with the satisfactory representation of intrapellet spatial effects.

전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가 (Shear bond strength of dentin bonding agents cured with a plasma arc curing light)

  • 권영철;김선영;정세준;한영철;이인복;손호현;엄정문;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.213-223
    • /
    • 2008
  • 광물리학적 특성 분석을 위해 Apollo 95E (DMT Systems, Orange, CA; PAC 광중합기), Elipar Freelight 2 (3M ESPE, MN, USA; LED 광중합기) 그리고 VIP Junior (Bisco, Schaumberg, IL, USA; QTH 광중합기), 3종의 광중합기의 총광강도(Total intensity)와 spectral distribution을 측정하였고 특정 파장에 해당되는 광강도 (Energy density)를 분석하였다. 상아질 전단접착강도의 측정을 위해 Scotchbond Multipurpose (3M ESPE), Single bond (3M ESPE) 그리고 Clearfil SE bond (Kuraray)가 사용되었다. Plasma Arc Curing light (Apollo 95E) 광중합기는 여러개의 최대정점을 가지며 넓은 spectral distribution과 $2307mw/cm^2$의 높은 광강도를 나타내었고, VIP Junior 광중합기는 490nm에서 최대정점을 갖는 넓은 spectral distribution을 나타내었고, Elipar Freeelight 2 광중합기는 462 nm의 최대정점 주위로 좁은 spectral distribution을 보였다. Two-Way ANOVA와 Bonferroni's multiple comparison test를 이용하여 상아질 전단접착강도를 분석한 결과, PAC 광중합기와 LED 광중합기 간에 유의성 있는 차이를 보이지 않았으며 (P > 0.05), 상아질 접착제와 광중합기의 교호관계에도 유의성이 없었다. 그러나 상아질 접착제는 상호간에 유의성 있는 차이를 보였다 (P < 0.001).

전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가 (Shear bond strength of dentin bonding agents cured with a plasma arc curing light)

  • 권영철;김선영;정세준;한영철;이인복;손호현;엄정문;조병훈
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.213-223
    • /
    • 2008
  • 광물리학적 특성 분석을 위해 Apollo 95E (DMT Systems, Orange, CA : PAC 광중합기), Elipar Freelight 2 (3M ESPE, MN, USA; LED 광중합기) 그리고 VIP Junior (Bisco, Schaumberg, IL, USA : QTH 광중합기), 3종의 광중합기의 총광강도(Total intensity)와 spectral distribution을 측정하였고 특정 파장에 해당되는 광강도(Energy density)를 분석하였다. 상아질 전단접착강도의 측정을 위해 Scotchbond Multipurpose (3M ESPE), Single bond (3M ESPE) 그리고 Clearfil SE bond (Kuraray)가 사용되었다. Plasma Arc Curing light (Apollo 95E) 광중합기는 여러개의 최대정점을 가지며 넓은 spectral distribution과 $2307mW/cm^2$의 높은 광강도를 나타내었고, VIP Junior 광중합기는 490 nm에서 최대정점을 갖는 넓은 spectral distribution을 나타내었고, Elipar Freeelight 2 광중합기는 462 nm의 최대정점 주위로 좁은 spectral distribution을 보였다. Two-Way ANOVA와 Bonferroni's multiple comparison test를 이용하여 상아질 전단접착강도를 분석한 결과, PAC 광중합기와 LED 광중합기 간에 유의성 있는 차이를 보이지 않았으며 (P > 0.05), 상아질 접착제와 광중합기의 교호관계에도 유의성이 없었다. 그러나 상아질 접착제는 상호간에 유의성 있는 차이를 보였다 (P < 0.00).

  • PDF

Real scale lunar apparent albedo and moonshine simulation with improved 3D lunar optical model with Apollo 10084 soil sample

  • 유진희;김석환
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.210.2-210.2
    • /
    • 2012
  • Using Fresnel reflection and Hapke BRDF model with Apollo 10084 soil sample's scattering properties, we constructed a real scale optical lunar model and used it to simulate lunar apparent albedo and moonshine. For Fresnel reflection, the refractive index of $1.68{\pm}0.5$ was used. For Hapke BRDF parameters from BUGs BRDF measurement, the single scattering with w=0.33, hot spot width h=0.017, average phase angle ${\zeta}$=-0.086 and Legendre polynomial coefficients b=0.308, c=0.425 in wavelength 700nm with two types of Henyey-Greenstein phase function was applied. The computation model includes the Sun as a Lambertian scattering sphere, emitting 1.5078 W/m2 at 700nm in wavelength. The Sun and Moon models were then imported into the IRT based radiative transfer computation. The trial simulation of the irradiance levels of moonshine lights shows that they agree well with the ROLO measurement data. We then estimate the lunar apparent albedo to 0.11. The results are to be compared with the measurement data.

  • PDF

중합광원과 레진 색상이 복합레진의 중합깊이에 미치는 영향 (EFFECT OF LIGHT SOURCE AND SHADE ON DEPTH OF CURE OF COMPOSITES)

  • 나준석;정선와;황윤찬;김선호;윤창;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제27권6호
    • /
    • pp.561-568
    • /
    • 2002
  • Purpose of this research is estimating polymerization depth of different source of light. XL 3000 for halo-gen light, Apollo 95E for plasma arc light and Easy cure for LED light source were used in this study. Different shade (B1 & A3) resin composites (Esthet-X, Dentsply, U.S.A.) were used to measure depth of cure. 1, 2, and 3 mm thick samples were light cured for three seconds, six seconds or 10 seconds with Apollo 95E and they were light cured with XL-3000 and Easy cure for 10 seconds, 20 seconds, or 40 seconds. Vicker's hardness test carried out after store samples for 24 hours in distilled water. Results were as following. 1. Curing time increases from al1 source of lights, oui$.$ing depth increased(p<0.05). 2. Depth (that except 1mm group and 2mm group which lighten to halogen source of light) deepens in all groups, Vickers hardness decreased(p<0.05). 3. Vicker's hardness of A3 shade composite was lower in all depths more than B1 shade composites in group that do polymerization for 10 seconds and 20 seconds using halogen source of light(p<0.05), but group that do polymerization lot 40 seconds did not show difference(p>0.05). 4. Groups that do polymerization using Plasma arc and LED source of light did not show Vicker's hardness difference according to color at surface and 1mm depth(p>0.05), but showed difference according to color at 2mm and 3mm depth(p<0.05). The results showed that Apollo 95E need more polymerization times than manufacturer's recommendation (3 seconds), and Easy cure need polymerization time of XL-3000 at least.