• Title/Summary/Keyword: APF

Search Result 214, Processing Time 0.026 seconds

Experimental Research on the Surface Changes and the Abrasion Resistance of Pit and Fissure Sealant by Fluoride (불소도포제에 의한 치면열구전색제의 마모저항성과 표면 변화에 관한 실험연구)

  • Hwang, Su-Hyun;Yu, Ji-Su
    • Journal of dental hygiene science
    • /
    • v.10 no.5
    • /
    • pp.373-378
    • /
    • 2010
  • To test the effects of representative fluoride vanishes-1.23% APF gel and 5% NaF Fluoride Varnish-on the surface structure of pit and fissure sealant, this study classified samples of pit and fissure sealant into five groups: Group I deposited in distilled water for ten minutes, Group II treated with APF gel for one minute, Group III treated with APF gel for four minutes, Group IV treated with Fluoride Varnish for one minute, and Group V treated with Fluoride Varnish for four minutes. An abrasion test was carried out to measure changes in weight, along with observation of the surface structure by using an optical microscope, consequently drawing the following conclusions. 1. The results of the abrasion test using pit and fissure sealant, Concise, showed that Group III had the reduction in weight more increased than Group I and that Group V had less reduction in weight (p<0.05); the results of the abrasion test using Eco-S showed Group III had the reduction in weight more increased than Group I and that Group V had less reduction in weight (p<0.05). 2. The results of observation using an optical microscope showed that application of APF gel made the filler remarkable due to loss of substrate and that Group III treated with APF gel for four minutes had the toughest surface, followed by Group II treated with APF gel for one minute, Group I deposited in distilled water for ten minutes, Group IV treated with Fluoride Varnish for one minute, and Group V treated with Fluoride Varnish for four minutes.

Clinical evaluation of a collagen matrix to enhance the width of keratinized gingiva around dental implants

  • Lee, Kang-Ho;Kim, Byung-Ock;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.96-101
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of collagen matrix with apically positioned flap (APF) on the width of keratinized gingiva, comparing to the results of APF only and APF combined with free gingival graft (FGG) at the second implant surgery. Methods: Nine patients were selected from those who had received treatments at the Department of Periodontics, Chosun University Dental Hospital, Gwangju, Korea. We performed APF, APF combined with FGG, and APF combined with collagen matrix coverage respectively. Clinical evaluation of keratinized gingival was performed by measuring the distance from the gingival crest to the mucogingival junction at the mid-buccal point, using a periodontal probe before and after the surgery. Results: The ratio of an increase was 0.3, 0.6, and 0.6 for the three subjects in the APF cases, 3, 5, and 7 for the three in the APF combined with FGG case, and 1.5, 0.5, and 3 for the three in the APF combined with collagen matrix coverage case. Conclusions: This study suggests that the collagen matrix when used as a soft tissue substitute with the aim of increasing the width of keratinized tissue or mucosa, was as effective and predictable as the FGG.

A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement (전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구)

  • 손진근
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.238-245
    • /
    • 2003
  • In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

Immune-Enhancing Effects of Polysaccharides Isolated from Ascidian (Halocynthia roretzi) Tunic (우렁쉥이(Halocynthia roretzi) 껍질로부터 분리된 다당류의 면역증강 효과)

  • Lee Dae-Hoon;Hong, Joo-Heon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.5
    • /
    • pp.673-680
    • /
    • 2015
  • In this study, the immune-enhancing effects of purified polysaccharides from ascidian (Halocynthia roretzi) tunic were investigated. Crude polysaccharides (AP) were isolated by enzyme extraction (neutrase, $60^{\circ}C$, 15h), ethanol precipitation, and lyophilization. In addition, crude polysaccharides were further fractionated into unabsorbed fractions (APF-I, fraction No. 11~17) and absorbed fractions (APF-II, fraction No. 22~37) by DEAE-sepharose CL-6B column chromatography in order to isolate immune regulating polysaccharide. The major constituents in APF-I and APF-II were total sugar (66.62% and 27.03%), uronic acid (47.53% and 15.87%), hexosamine (16.62% and 46.79%), and protein (2.43% and 4.94%), respectively. APF-I increased production of nitric oxide (NO) and cytokines, such as tumor necrosis factor-alpha (TNF-${\alpha}$) and interleukin (IL)-6 in a dose-dependent manner. The mRNA expression levels of inducible NO synthetase, cyclooxygenase-2, TNF-${\alpha}$, and IL-6 were markedly increased as determined by polymerase chain reaction analysis. The above data led us to conclude that macrophage activation of purified polysaccharides was higher than that of crude polysaccharides. The polysaccharides isolated from ascidian tunic investigated herein are useful as natural immune enhancing agents.

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

CHANGES IN ADHESION OF STREPTOCOCCUS MUTANS TO NANOCOMPOSITE RESINS AFTER ACIDULATED PHOSPHATE FLUORIDE GEL APPLICATION (나노컴포지트에서 Acidulated Phosphate Fluoride 적용에 따른 Streptococcus mutans 부착량 변화)

  • Jung, Young-Jung;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.427-436
    • /
    • 2005
  • Topical application of APF gel can increase the surface roughness of resin composites and the roughened surfaces may allow increased bacterial accumulation and surface staining. Resin specimens of two proprietary resin composites, Filtek Z250(FZ) and Filtek Supreme Universal(FS), and experimental resin composites containing 0%, 3%, 6% nanofillers(E0, E3, E6) were fabricated and divided into two groups of the same number; APF treatment group and no treatment group. The amount of S. mutans adhered to specimens and the mean surface roughness(Ra) were measured. The results were as follows; 1. In no treatment group, the amount of S. mutans adhered to FS was the smallest. It was significantly different from those of FZ, E3, E6(p<0.05) although it was not significantly different from that of E0(p>0.05). 2. For all resin composites used, the amount of S. mutans adhesion in APF treatment group was significantly greater than that in no treatment group(p<0.05). 3. In APF treatment group, the amount of S. mutans adhesion was significantly different between materials(p<0.05), and increased in order of FS, FZ, E0, E3 and E6. 4. Difference of the surface roughness(Ra) between materials was not statistically significant in both no treatment group and APF treatment group(p>0.05)

  • PDF

Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load (싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정)

  • Park, No-Jung;Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.12
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF

A retrospective comparison of 3 approaches of vestibuloplasty around mandibular molar implants: apically positioned flap versus free gingival graft versus modified periosteal fenestration

  • Lee, Won-Pyo;Lee, Kyoung-Hoon;Yu, Sang-Joun;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.5
    • /
    • pp.364-372
    • /
    • 2021
  • Purpose: This study aimed to clinically evaluate the efficacy of vestibuloplasty around lower molar implants using 3 different modalities: apically positioned flap alone (APF), APF with a free gingival graft (FGG), and APF with modified periosteal fenestration (mPF). Methods: Three different vestibuloplasty procedures during second-stage implant surgery were performed at the mandibular molar area in 61 patients with a shallow vestibule and insufficient keratinized tissue (KT). The clinical measurements of KT width were recorded at baseline, immediately after surgery (T0), 6 months after surgery (T6), and 12 months after surgery (T12). Soft tissue esthetic scores were measured. Results: An additional KT width gain from baseline to T12 of approximately 2 mm was obtained with FGG and mPF compared to that with APF. Shrinkage of the re-established tissue was lower with mPF and FGG than with APF, whereas the esthetic profile was better with APF and mPF than with FGG. Conclusions: Within the limitations of this study, mPF showed potential as a promising approach for vestibuloplasty around the lower molar implants compared to the traditional APF and FGG.

ESTIMATION OF REQUIRED CAPACITY OF SHUNT TYPE ACTIVE POWER FILTER WITH A THYRISTOR CONVERTER LOAD

  • Jeong, Seung-Gi;Kim, Dong-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.802-807
    • /
    • 1998
  • The main drawback of parallel type active power filters (APF) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement of harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. And it is shown that the APF capacity can be considerably reduced while slightly sacrificing the filtering performance by deliberately limiting the peak current of the APF.

  • PDF

A Study on the Effect of Multi-Application of Fluoride on Enamel Remineralization (불화물 복합적용이 법랑질의 재석회화에 미치는 영향에 관한 연구)

  • Cho, Min-Jung;Lee, Hyang-Lim
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.125-132
    • /
    • 2001
  • This study was carried out to investigate the effect of multi or single application of fluoride plus 0.05% NaF solution on the remineralization of dental caries lesion. The microhardness changes of enamel surface were measured after application of fluoride and precipitation of 0.05% NaF solution on 6 groups of cow's tooth on which the artificial carious lesions were formed first. Test groups were calssified into two step application with NaF, $SnF_2$ and APF under different application time conditions plus 0.05% NaF solution(group I, II, III, IV) and single application with APF plus 0.05% NaF solution (group V) and control(0.05% NaF solution only, group IV). The obtained results were as follows. 1. Regarding microhardness change of enamel surface. microhardness increments in group I(NaF for 1 minute+APF for 3 minutes+0.05% NaF solution for 1 minute), II($SnF_2$ 1 min+APF 3 min+NaF sol.), III($SnF_2$ 2 min+APF 2 min+NaF sol.), IV(NaF 2 min+APF 2 min+NaF sol.) and V(APF 4 min+NaF sol.) were significantly greater than group VI.(P<0.05) 2. Microhardness changes of shorter application time of $SnF_2$ (group II) were significantly greater than group III. (P<0.05) 3. Microhardness changes were variable with kinds of fluoride, application sequence and application time of fluoride. but had no relation with the number of fluoride application.

  • PDF