• Title/Summary/Keyword: APEX

Search Result 1,145, Processing Time 0.026 seconds

A STUDY ON THE ROOT CANAL MORPHOLOGY CHANGE BY NICKEL-TITANIUM AND STAINLESS STEEL FILE INSTRUMENTATION USING COMPUTERIZED TOMOGRAPHY (Nickel-Titanium file과 Stainless steel file을 이용한 근관형성시 컴퓨터 단층촬영사진상의 근관형태 변화에 관한 연구)

  • So, Mun-Seop;Im, Mi-Kyung;Lee, Keon-Il;Lee, Yong-Keun;Lee, Su-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.659-669
    • /
    • 1997
  • The goals of root canal instrumentation are complete debridement of pulp tissue, removal of microbes and affected dentin, and proper cleaning and shaping of the root canal space before obturation. Instrumentation with stainless steel files has been shown to produce undesirable results in canals, regardless of the improved technique or modified file type used. Nickel-Titanium(Ni-Ti) alloy has been shown to be exceptionally elastic, having a lower bending moment and lower permanent set after torsion, compared with similar gauge stainless steel. The purpose of this study was to evaluate the change of root canal prepared by Ni-Ti rotary and stainless steel instruments. Thirty-four single rooted teeth of similar shape and canal size were divided into three groups. The teeth were scanned by computed tomography before instrumentation. In group 1, canals were instrumented using a step-back technique with K-file. In group 2, canals were prepared with K-flex file using the same technique as group 1. Group 3 was prepared with nickel-titanium(Ni-Ti) rotary instrument using a manufacture's instruction. Instrumented teeth were again scanned using computed tomography, and reformated images of the uninstrumented canals were compared with images of the instrumented canals. K-flex file and Ni-Ti file caused significantly less canal transportation than K-file in the 8mm root canal section from the apex(p<0.05). K-flex file and Ni-Ti file produced more centered canal preparation than K-file in the 2mm section(p<0.05). Ni-Ti file maintained more precisely the center of the canal than K-flex file in the 10mm section (p<0.05). There was no difference in the removed volume of canals among each groups.

  • PDF

The EFFECTS OF VARIOUS INSTRUMENTATION TECHNIQUES IN CURVED CANALS OF RESIN BLOCKS (만곡근관에서 수동식 기구와 엔진 구동형 기구의 근관성형 효과에 대한 비교 연구)

  • Jung, Il-Young;Yoon, Tai-Cheol;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.648-658
    • /
    • 1997
  • The purpose of this study was to compare the effects of various techniques on the quality and quantity of instrumentation in curved canals. Instrumentation time was evaluated too. Forty eight canals of resin blocks($35^{\circ}$) were divided into three groups and filed. In group A, 16 blocks were instrumented using a step-back technique with stainless steel(SS) K-file(Mani, Matsutani Seisakusho Co.,Japan). In group B, canals were prepared with SS K-files using the Endo-Angle (Nakanishi Dental MFG.CO.,LTD.,Japan). Group C was prepared using N i-Ti engine-driven instruments (Quantec Series $2000^{TM}$ system). Group A and B were filed from # 5 to # 25 at the apex followed by a 1 mm stepback technique, and the coronal half of the canals were flared with Gates Glidden burs(#2,3,4). Group C was instrumented from # 1 to # 8. After the instrumentation time was measured, canals were filled with India ink, and photographed, which to magnify the canal images 8 times. Using these photographs the apical portions were evaluated And scored from 1 to 4 according to the severity of ledging and zipping. On the same photographs, the area of the coronal two thirds of the canals were measured using a personal computer with the computer program Brain and Digitizer (SummaSketch III). The following results were obtained. 1. Instrumentation time was significantly shorter for group C, as opposed to group A and B(ANOVA, P<0.05). 2. The qualitative evaluation of the apical portions of the canals showed no significant difference between the groups(Kruscal-Wallis, p>0.05). 3. The area removed by group C was significantly smaller than group A and B(ANOVA, P<0.05).

  • PDF

Fabrication of Nano Dot and Line Arrays Using NSOM Lithography

  • Kwon Sangjin;Kim Pilgyu;Jeong Sungho;Chang Wonseok;Chun Chaemin;Kim Dong-Yu
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.16-21
    • /
    • 2005
  • Using a cantilever type nanoprobe having a 100㎚m aperture at the apex of the pyramidal tip of a near-field scanning optical microscope (NSOM), nanopatterning of polymer films are conducted. Two different types of polymer, namely a positive photoresist (DPR-i5500) and an azopolymer (Poly disperse orange-3), spincoated on a silicon wafer are used as the substrate. A He-Cd laser with a wavelength of 442㎚ is employed as the illumination source. The optical near-field produced at the tip of the nanoprobe induces a photochemical reaction on the irradiated region, leading to the fabrication of nanostructures below the diffraction limit of the laser light. By controlling the process parameters properly, nanopatterns as small as 100㎚ are produced on both the photoresist and azopolymer samples. The shape and size variations of the nanopatterns are examined with respect to the key process parameters such as laser beam power, irradiation time or scanning speed of the probe, operation modes of the NSOM (DC and AC modes), etc. The characteristic features during the fabrication of ordered structures such as dot or line arrays using NSOM lithography are investigated. Not only the direct writing of nano array structures on the polymer films but also the fabrication of NSOM-written patterns on the silicon substrate were investigated by introducing a passivation layer over the silicon surface. Possible application of thereby developed NSOM lithography technology to the fabrication of data storage is discussed.

Universality of the Quasi-linear Relation Between the Order Parameter and the Normalized Birefringence of Aligned Uniaxially Anisotropic Molecules (정렬된 단축이방성 분자들의 질서변수와 상대 복굴절간 준선형 관계식의 보편성)

  • Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.33-38
    • /
    • 2017
  • The universality of the quasi-linear relation between the order parameter S and the normalized birefringence ${\Delta}n_{rel}$, $S=(1+a){\Delta}n_{rel}-a{\Delta}n^2_{rel}$ is confirmed. It is verified that the refractive index of liquid crystals distributed with regular polyhedral symmetry is isotropic and it is given as $\frac{1}{n^2_{av}}=\frac{1}{3}\(\frac{1}{n^2_e}+\frac{2}{n^2_o}\){\cdot}S$ and ${\Delta}n_{rel}$ of angular weighted liquid crystals that are initially distributed with regular polyhedral symmetry, are numerically calculated. Also ${\Delta}n_{rel}$ and S of liquid crystals that are conically distributed, keeping the rotational symmetry about z-axis are calculated as the apex angle of the cone is varied. Based on these calculated results, it is confirmed that the quasi-linear relation between S and ${\Delta}n_{rel}$ is universal, independent of the details of the distribution function.

Plasma pretreatment of the titanium nitride substrate fur metal organic chemical vapor deposition of copper (Cu-MOCVD를 위한 TiN기판의 플라즈마 전처리)

  • Lee, Chong-Mu;Lim, Jong-Min;Park, Woong
    • Korean Journal of Materials Research
    • /
    • v.11 no.5
    • /
    • pp.361-366
    • /
    • 2001
  • It is difficult to obtain high Cu nucleation density and continuous Cu films in Cu-MOCVD without cleaning the TiN substrate prior to Cu deposition. In this study effects of plasma precleaning on the Cu nucleation density were investigated using SEM, XPS, AES, AFM analyses. Direct plasma pretreatment is much more effective than remote plasma pretreatment in enhancing Cu nucleation. Cleaning effects are enhanced with increasing the rf-power and the plasma exposure time in hydrogen plasma pretreatment. The mechanism through which Cu nucleation is enhanced by plasma pretreatment is as follows: Hydrogen ion\ulcorner in the hydrogen plasma react with TiN to form Ti and $NH_3$ Cu nucleation is easier on the Ti substrate than TiN substrate.

  • PDF

A MECHANICAL INVESTIGATION OF CORNEAL REFRACTIVE SURGERIES AND PROPOSITION OF NEW TECHNIQUES (각막굴절수술의 역학적 고찰 및 새로운 기법의 시도)

  • Shin, J.W.;Han, G.J.;Whang, M.C.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.95-100
    • /
    • 1995
  • This study investigated the effects of mechanical factors involved in several corneal refractive surgeries on the surgical outcomes. Then we proposed possible new techniques from the mechanical point of a view utilizing finite element method. The models studied are: circumferential keratetomy, combination of excimer laser photorefractive keratectomy and circumferential keratotomy for myopia treatment, arcuate keratotomy for astigmatism treatment. The cornea was assumed to be nonlinear elastic and almost incompressible material as the most soft tissue in the human body. In the circumferential keratotomy the effect of the incision location was investigated. The angle and location of the incision were varied to predict the surgical outcomes in the arcuate keratotomy. The finite element analysis results showed that the location of incision was a critical factor affecting the surgical outcomes in the circumferential keratotomy. In the combination of the excimer laser photorefractive keratectomy and circumferential keratotomy, it was predicted that the circumferential can increase or decrease the refractive power depending on the incision location or it can be used to adjust the overcorrection of undercorrection. In the arcuate keratotomy for astigmatism, the most diopter changes were predicted when the location and the angle of the incision were 3.0mm from the apex and $90^{\circ}$, respectively. In the arcuate keratotomy, the effects of an incision were studied within the incision area as well as outside the incision area. Also, the arcuate keratotomy with two incisions located on the opposite area of the cornea was also studied. As a conclusion, the finite element method is a useful technique in the area of corneal refractive surgeries to develop new techinques.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECT OF VARIOUS HYDROXIDES UPON THE PULP IN DOGS' TEETH (수종수산화물(數種水酸化物)이 치수조직(齒髓組織)에 미치는 영향(影響)에 관(關)한 실험적연구(實驗的硏究))

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.1 no.1
    • /
    • pp.26-32
    • /
    • 1975
  • After a vital pulpotomy in dogs' teeth, the responses of the remaining pulp tissue under hydroxides (calcium hydroxide, magnesium hydroxide, aluminium hydroxide and zinc hydroxide) were studied histologically. The class V cavities were prepared on the teeth and the pulp was amputated. Each hydroxide was placed over the amputated tissue and the cavity was sealed with zinc oxide eugenol cement. Animals were sacrificed after 3 days, 1, 2, and 3 weeks following the operation. The teeth were decalcified, sectioned and stained with hematoxylin and eosin. Microscopic examination reveals as follows; 1. Calcium hydroxide: Inflammatory change was seen in the superficial portion of the remaining pulp tissue at the 3rd day and 1st week. The incompleted calicified material began to be deposited from the canal wall at the 2nd week, and the advanced calcified material was seen at the 3rd week. 2. Magnesium hydroxide: Severe inflammatory change was seen in the superficial portion of the remaining pulp from the 3rd day and the 1st week samples. Inflammatory change was decreased at the 2nd week and the slight calcified material was deposited from the root canal at the 3rd week. 3. Aluminium hydroxide: Severe inflammatory changes were seen in the remaining pulp tissue, the blood vessel was dilated, and the odontoblasts were destroyed at the 3rd day and 1st week. The fibrous degeneration spread to the apex at the 2nd week. There was no evidence of newly formed odontoblasts or deposition of calcified material underneath aluminium hydroxide. 4. Zinc hydroxide: The micrscopic picture was destructive. A thick necrotic layer was found under the amputated surface at the 3rd day and 1st week. Granulation tissue formation as well as chronic inflammatory changes extended to the apical area in the pulp tissue. Also there were no sign of odontoblastic formation or calcified material at the 2nd and 3rd week.

  • PDF

Effects of canal enlargement and irrigation needle depth on the cleaning of the root canal system at 3 mm from the apex (근관확대 및 세척 주사바늘의 근관 내 위치가 치근단 3 mm 부위의 근관 세정에 미치는 영향)

  • Moon, Ho-Jin;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of ${\times}250$, ${\times}500$, ${\times}1,000$, ${\times}2,500$ were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.

Corydalis cornupetala Y.H. Kim et J.H. Jeong: A New Species of Corydalis sect. Corydalis (Fumariaceae) (쇠뿔현호색: 현호색속 현호색절의 1신종)

  • Kim, Young-Hee;Jeong, Ji-Hee;Jo, Dong-Gwang;Kim, Zin-Suh
    • Korean Journal of Plant Taxonomy
    • /
    • v.37 no.3
    • /
    • pp.217-224
    • /
    • 2007
  • A new species of Corydalis sect. Corydalis (Fumariaceae), Corydalis cornupetala Y.H. Kim et J.H. Jeong is described from Gyeongsan-si, Gyeongsangbuk-do in Korea. This new species is distinguished from the other species of the sect. Corydalis by some flower characters such as, purplish white petal with two dark stripes and horn-shaped apex of outer petal. The linear leaflets of C. cornupetala are similar to the lineariloba type of C. remota Fisch. ex Max. or C. namdoensis B.U. Oh et J.G. Kim, but much longer and narrower. The linear or lanceolate bract of C. cornupetala is also distinctive from the elliptical shape of C. remota and C. namdoensis.

A new record of Lycopus charkeviczii Prob. (Lamiaceae) in Korea (한국 미기록 식물 산쉽싸리(꿀풀과))

  • Son, Dong Chan;Yang, Jong-Cheol;Kim, Hyun-Jun;Lee, Kang-Hyup;Ji, Seong-Jin;Chang, Kae Sun
    • Korean Journal of Plant Taxonomy
    • /
    • v.46 no.1
    • /
    • pp.117-123
    • /
    • 2016
  • Lycopus charkeviczii Prob. (Lamiaceae Martinov) is found in all provinces of the Korean Peninsula, excluding Jeju-do. This species is closely related to L. lucidus Turcz. ex Benth., having such characters as persistent calyx of which the length is longer than the nutlets, and narrowly lanceolate to oblong-lanceolate leaves. However, it is distinguished from L. lucidus by its parted calyx and its smooth or rarely glandular nutlets with an irregularly toothed apex. This taxon was named 'San-swip-ssa-ri' in Korean based on its habitat. We provide a description, illustrations, photographs, and a key of related taxa in Korea.