• Title/Summary/Keyword: APEX

Search Result 1,144, Processing Time 0.028 seconds

A New Variety of Geranium (Geraniaceae) from Korea: G koraiense Nakai var. hallasanense B.-J. Woo & S.-J. Park

  • Woo, Bok-Ju;Park, Seon-Joo
    • Animal cells and systems
    • /
    • v.9 no.3
    • /
    • pp.123-125
    • /
    • 2005
  • A new variety, Geranium koraiense var. hallasanense B.-J. Woo & S.-J. Park, is described here from Jeju Island, Korea. The new variety is distributed only in Jeju Island, and readily distinguished from the other varieties of G. koraiense by its shape of radical leaf division, rounded or undulate petal apex, glabrous petal veins, densely pubescent stems, and stylar portion pubescent with trichomes in basal 1/4 portion. A key to the varieties of G. koraiense is provided.

Lecanorchis japonica var. insularis (Orchidaceae: Vanilloideae), a new variety from Jejudo Island, Korea

  • SEO, Seon-Won;CHUNG, Mi-Sook;CHUNG, Young-Soon;LIM, Chae Eun;OH, Sang-Hun
    • Korean Journal of Plant Taxonomy
    • /
    • v.50 no.4
    • /
    • pp.413-418
    • /
    • 2020
  • A new variety, Lecanorchis japonica var. insularis (Orchidaceae: Vanilloideae), a mycoheterotrophic orchid from Jejudo Island, Korea, is described and illustrated. It usually grows with L. japonica var. japonica, L. japonica var. hokurikuensis and L. kiusiana in evergreen forests. The newly described variety is distinguished from L. japonica vars. japonica, hokurikuensis, and kiiensis by having fully opened, larger flowers and an obtuse labellum apex.

Taxonomic study of the genus Diplazium (Woodsiaceae) in Korea (한국산 참빗고사리속(우드풀과)의 분류)

  • Lee, Chang Shook
    • Korean Journal of Plant Taxonomy
    • /
    • v.35 no.3
    • /
    • pp.175-186
    • /
    • 2005
  • Cladistic analysis was performed to reveal the interspecific relationship of nine taxa of Korean Diplazium (Woodsiaceae). A total of 29 taxa with 20 taxa of eastern asiatic species as ingroup and three taxa of Athyrium as outgroup, were analyzed with 17 morphological characters. Diplazium nipponicum, recently found from Jeju Island, was most closely related to D. chinense by having the acuminate apex of pinnule segment and fascicled fronds. Diplazium nipponicum was distinguished from D. chinense by having scales and pinnule segments of serrated margin, and non-overlapped pinnules. Diplazium nipponicum and D. chinense were closely related to D. mesosorum and D. hajizoense in sequence, by having long acute apex in pinnae. These species formed same clade with D. subtripinnatum, which is endemic to Japan and D. kawakamii, which is distributed in Japan and Taiwan.

Dynamics of Nanopore on the Apex of the Pyramid

  • Choi, Seong-Soo;Yamaguchi, Tokuro;Park, Myoung-Jin;Kim, Sung-In;Kim, Kyung-Jin;Kim, Kun-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.187-187
    • /
    • 2012
  • In this report, the plasmonic nanopores of less than 5 nm diameter were fabricated on the apex of the pyramidal cavity array. The metallic pyramidal pit cavity can also utilized as the plasmonic bioreactor, and the fabricated Au or Al metallic nanopore can provide the controllable translocation speed down using the plasmonic optical force. Initially, the SiO2 nanopore on the pyramidal pit cavity were fabricated using conventional microfabrication techniques. Then, the metallic thin film was sputter-deposited, followed by surface modification of the nanometer thick membrane using FESEM, TEM and EPMA. The huge electron intensity of FESEM with ~microsecond scan speed can provide the rapid solid phase surface transformation. However, the moderate electron beam intensity from the normal TEM without high speed scanning can only provide the liquid phase surface modification. After metal deposition, the 100 nm diameter aperture using FIB beam drilling was obtained in order to obtain the uniform nano-aperture. Then, the nanometer size aperture was reduced down to ~50 nm using electron beam surface modification using high speed scanning FESEM. The followed EPMA electron beam exposure without high speed scanning presents the reduction of the nanosize aperture down to 10 nm. During these processes, the widening or the shrinking of the nanometer pore was observed depending upon the electron beam intensity. Finally, using 200 keV TEM, the diameter of the nanopore was successively down from 10 nm down to 1.5 nm.

  • PDF

Identification of 11 species of Paemo through each original plant and medicines (11종 패모(貝母)의 기원별 자연·약재상태 감별)

  • Lee, Seungho;Ju, Youngsung
    • The Korea Journal of Herbology
    • /
    • v.29 no.6
    • /
    • pp.133-140
    • /
    • 2014
  • Objectives : Paemo is a phlegm-resolving drug with cold properties and classified 5 kinds which come from 11 species of original plant. All the more, according to literature record, 20 species of original plant were used. As a natural result, these are easily to confuse and there are a lot of counterfeit product. So we are to present a differential standard of Paemo. Methods : It was planed a differential standard form through outer appearance of the original plant and outer appearance in the form of each medicines which was collected local market or field for 11 species which is listed in Korea or China pharmacopeia. Results : It was possible to distinguish the orignal plant between Fritillaria and Bolbostemma through its stem shape. In Fritillaria of original plant, it was possible to distinguish through its width of leaf, number of leafy bracts, color and position of flower and shape of leaf apex. In outer appearance in the form of each medicines, there are difference in color and texture of medicine between Fritillaria and Bolbostemma and there are difference in size, shape, size of inner and outter fleshy leaf of bulb, pattern of surface and apex of fleshy leaf of bulb among 10 Fritillaria species. Conclusions : This study presents various differences in the outer appearance of the original plant and the outer appearance in the form of each medicines among Paemo. It will be helpful to further applied research.

Minimizing the extra-oral time in autogeneous tooth transplantation: use of computer-aided rapid prototyping (CARP) as a duplicate model tooth

  • Lee, Seung-Jong;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.136-141
    • /
    • 2012
  • Objectives: The maintenance of the healthy periodontal ligament cells of the root surface of donor tooth and intimate surface contact between the donor tooth and the recipient bone are the key factors for successful tooth transplantation. In order to achieve these purposes, a duplicated donor tooth model can be utilized to reduce the extra-oral time using the computer-aided rapid prototyping (CARP) technique. Materials and Methods: Briefly, a three-dimensional digital imaging and communication in medicine (DICOM) image with the real dimensions of the donor tooth was obtained from a computed tomography (CT), and a life-sized resin tooth model was fabricated. Dimensional errors between real tooth, 3D CT image model and CARP model were calculated. And extra-oral time was recorded during the autotransplantation of the teeth. Results: The average extra-oral time was 7 min 25 sec with the range of immediate to 25 min in cases which extra-oral root canal treatments were not performed while it was 9 min 15 sec when extra-oral root canal treatments were performed. The average radiographic distance between the root surface and the alveolar bone was 1.17 mm and 1.35 mm at mesial cervix and apex; they were 0.98 mm and 1.26 mm at the distal cervix and apex. When the dimensional errors between real tooth, 3D CT image model and CARP model were measured in cadavers, the average of absolute error was 0.291 mm between real teeth and CARP model. Conclusions: These data indicate that CARP may be of value in minimizing the extra-oral time and the gap between the donor tooth and the recipient alveolar bone in tooth transplantation.

Comparison of Gait Stability of using an Outdoor Rollator with Walking and using a Bassinet as Ambulatory Aid

  • Park, Min-Su;Park, Soo-Hee;Yang, Yeong-Ae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.327-336
    • /
    • 2012
  • Objective: The purpose of this study is to find the problems of stability when people use the bassinet as an ambulatory aid for old people. Background: Many aged people use a bassinet as ambulatory aid. But the safety of using the bassinet as ambulatory aid has not been verified yet. Method: The 13 university-students who don't have musculoskeletal disorders volunteered to participate in this study. According to structural analysis of the both tools, we compared the structural stability of an outdoor rollator with the structural stability of a bassinet. And when the participants walked using both tools, the motions were captured and analysed. We measured the angle of shoulder joint and the angle of trunk from the ground when the participants were walking. And we found the distance from participants' pressure cone apex and greater trochanter. Results: Following the structural analysis, the bassinet has the lower structural stability than the outdoor rollator. When the people used the bassinet as ambulatory aid, the angle of the shoulder joint was bigger than to use the outdoor rollator. The angle of trunk wasn't different between the outdoor rollator and the bassinet. And distance from pressure cone apex to greater trochanter was far to use the bassinet than to use the outdoor rollator. Conclusion: Through the structure analysis and gait analysis of the bassinet and the outdoor rollator, we can be aware of that the bassinet has problem of stability. Therefore the people who use the bassinet as an ambulatory aid, especially supporting body weight, may be hurt due to the problems of stability. Application: This research can be used for developing a study of the ambulatory aid and preventing the accident when the aged people use the ambulatory aid.

Design of an One-Chip Controller for an Electronic Dispenser (전자 디스펜서용 단일 칩 제어기 설계)

  • Kim, Tae-Sang;Won, Young-Wook;Kim, Jeong-Beom
    • Journal of IKEEE
    • /
    • v.9 no.2 s.17
    • /
    • pp.101-107
    • /
    • 2005
  • This paper presents an one-chip controller for an electronic dispenser. The electronic dispenser is composed of electronic part and mechanical part. The electronic part is consisted of input keypad, micro-controller, display module, and pump module. In this paper we designed micro-controller for the electronic part. The micro-controller controls display module and pump module. The display module is composed by LCD device, and the pump module is composed by motor device . The micro-controller for an electronic dispenser is designed by VHDL. We used WX12864AP1 for the LCD device and SPS20 for the stepping motor. Also, the micro-controller is designed by Altera Quartus tool and verified with Agent 2000 Design-kit using APEX20K Device. In this paper, we present possibility to adopt of the biomedical device through the one-chip controller for the electronic dispenser.

  • PDF

Early hypopharyngeal cancer treated with different therapeutic approaches: a single-institution cohort analysis

  • Kim, Nalee;Lee, Jeongshim;Kim, Kyung Hwan;Park, Jong Won;Lee, Chang Geol;Keum, Ki Chang
    • Radiation Oncology Journal
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2016
  • Purpose: Early hypopharyngeal squamous cell carcinoma (HPSCC) is a rarely diagnosed disease, for which the optimal treatment has not been defined yet. We assessed patterns of failure and outcomes in early HPSCC treated with various therapeutic approaches to identify its optimal treatment. Materials and Methods: Thirty-six patients with stage I (n = 10) and II (n = 26) treated between January 1992 and March 2014 were reviewed. Patients received definitive radiotherapy (RT) (R group, n = 10), surgery only (S group, n = 19), or postoperative RT (PORT group, n = 7). All patients in both the R and PORT groups received elective bilateral neck irradiation. In the S group, 7 patients had ipsilateral and 8 had bilateral dissection, while 4 patients had no elective dissection. Results: At a median follow-up of 48 months, the 5-year locoregional control (LRC) rate was 65%. Six patients had local failure, 1 regional failure (RF), 3 combined locoregional failures, and 2 distant failures. There was no difference in 5-year LRC among the R, S, and PORT groups (p = 0.17). The presence with a pyriform sinus apex extension was a prognosticator related to LRC (p = 0.01) in the multivariate analysis. Patients with a bilaterally treated neck showed a trend toward a lower RF rate (p = 0.08). Conclusion: This study shows that patients with early stage HPSCC involving the pyriform sinus apex might need a tailored approach to improve LRC. Additionally, our study confirms elective neck treatment might have an efficacious role in regional control.