• 제목/요약/키워드: APDC

검색결과 27건 처리시간 0.022초

불꽃원자 흡수광법에 의한요중 카드뮴 배설량 측정의 지적조건 (Measurement conditions for cadmium in urine by flame atomic absorption spectrophotometry)

  • 최호춘;정규철
    • Journal of Preventive Medicine and Public Health
    • /
    • 제17권1호
    • /
    • pp.269-279
    • /
    • 1984
  • The optimum conditions for measuring cadmium content of less than 0.2ppm by flame atomic absorption spectrophotometry were investigated. The cadmium in urine was extracted by APDC-MIBK for the analysis by atomic absorption spectrophotometry after ashing them by a wet method. 1. Optimum conditions by APDC-MIBK and DDTC-MIBK extractions. The acidic aqueous solution was prepared with appropriate amount of 0.IN nitric acid, 5ml of 25% (W/V) sodium potasstum tartarate, 10ml of saturated ammonium sulfate, and 2ml of 2% APDC(or 1 ml of 5% DDTC) chelating agent. The total volume of solution was adjusted to 55 ml and pH to $2{\sim}10$ (or$7{\sim}10$). The aqueous solution was extracted with 10ml MIBK. Concentration of Triton X-100 did not effect the absorbance for APDC-MIBK extraction of cadmium, but absorbance decreased as the concentration increased for DDTC-MIBK extraction. The sensitivity and detection limits for the cadmium determination from APDC-MIBK extraction were 0.0038ppm and 0.0102, 0.0022ppm and 0.0116 for DDTC-MIBK, and 0.0132ppm and 0.0034 for 0.1N nitric acid. APDC-MIBK and DDTC-MIBK extractions were 3 times higher than 0.1N nitric acid for the sensitivity. 2. Excretion of cadmium in 24-hour urine by APDC-MIBK extraction. Determination of cadmium in urine by atomic absorption spectrophotometry of A.A. (Cd=2 mA) mode and B.C. (Cd=4 mA) mode and B.C. (Cd=4mA, $D_2=20mA$) mode showed some difference (p<0.05). The difference of cadmium determination and recovery according to method of standard additions and standard calibration curve method in urine was not significant (p>0.05, $93.48{\pm}11.78%,\;94.83{\pm}22.00%$). Excretion of cadmium in 24-hour urine collection from normal person and variance analysis within measurement variation was not significant (p>0.05), but between interindividual was significant (0.05). Determination of cadmium content by two different methods of flame atomic absorption spectrophotometry and dithizone colorimetry showed that the results from the two methods can be described by a regression line with a good correlation (y=1.0153x-0.2927, x=Cd by D.C., y=Cd by A.A.S., $r=0.8651^*$, p<0.01).

  • PDF

원자흡수 분광법에 의한 철광석중의 Mn, Co, Ni 및 Cu 의 정량. APDC-MIBK 추출계의 이용 (Determination of Mn, Co, Ni and Cu in Iron Oxide Ore by Atomic Absorption spectroscopy. Utilization of APDC-MIBK Extraction System)

  • 박미선;김연두;고광희
    • 대한화학회지
    • /
    • 제33권3호
    • /
    • pp.315-320
    • /
    • 1989
  • 철광석 중에 존재하는 미량 금속원소들을 분석하는 방법을 제시하였다. 분석방법은 ammonium pyrrolidinedithiocarbamate(APDC)-methyl isobutyl ketone(MIBK) 추출계와 원자흡수 분광법(AA)를 이용하였다. 철이 유기층으로 추출되는 것을 막기 위하여 가리움제로서 코발트, 니켈 및 구리의 분석시에는 pH $8{\sim}10$에서 citrate를, 그리고 망간 및 구리의 분석시에는 pH 6{\sim}7$에서 tiron을 가하였다. MIBK의 물에 대한 용해도를 줄이기 위해 NaCl을 염석제로 가하였다. 금속 추출용액의 안정도를 증가시키기 위한 방안으로 MIBK 금속 추출물을 질산 수용액으로 역추출하는 것을 검토하였다.

  • PDF

Excellent Moving Picture Resolution of PDP, Proved by the New Measurement System Developed by the APDC

  • Kawahara, I.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1685-1687
    • /
    • 2007
  • Excellent moving picture performance of plasma TV has been confirmed through the study and measurement using the method proposed by the APDC (Advanced PDP Development Center Corporation). Full-HD Plasma TVs with pixels of $1920{\times}1080[1]-[2]$, showed more than 900 TV-lines of resolution out of maximum scale of 1080, while typical LCD of the same pixel count showed only 1/3 of the plasma's performance. Moreover, even the latest 120Hz models of $1920{\times}1080$ LCD do not much PDPs with pixels of $1024{\times}768$, or $1366{\times}786$ in moving picture resolution. The measurement system proposed by the APDC showed very good agreement with subjective tests.

  • PDF

인계 폴리올을 이용한 난연성 폴리우레탄의 합성 및 특성 분석 (Synthesis and Characterization of Phosphorus Polyurethanes Using Phosphorus Polyols)

  • 김태윤;김용갑;임충선;서봉국;이원주
    • 접착 및 계면
    • /
    • 제20권2호
    • /
    • pp.61-65
    • /
    • 2019
  • 본 연구에서는 인계 폴리올을 phenylphosphonic dichloride (PPDC), allylphosphonic dichloride (APDC)에 ethylene glycol (EG)을 반응시켜 합성하였고 분자량이 880~1,560 g/mol의 폴리올 얻었다. 이를 이용하여 polycarbonate diol (PCD)와 함께 4,4'-diphenylmethane diisocyanate (MDI)와 중합하여 인계 폴리우레탄을 얻었다. 합성한 인계 폴리우레탄의 인의 합량이 높아질수록 열분해 온도는 감소하였지만 챠 (char)의 발생과 발생양이 증가하는 것을 확인하였다. 또한 UL-94V 시험법을 통하여 APDC를 포함하는 인계 폴리우레탄 인의 함유량이 0.5 wt%이상일 때 V-0의 난연등급되는 것을 확인하였다.

금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량 (Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension)

  • 한철우;인교;최종문;김선태;김영상
    • 분석과학
    • /
    • 제13권5호
    • /
    • pp.608-615
    • /
    • 2000
  • 물 시료에 존재하는 극 미량의 니켈과 코발트를 착물로 형성시켜 이온 교환수지 서스펜션에 흡착시켜 분리 농축하여 정량하는 방법을 연구하였다. 리간드로 APDC (ammonium pyrrolidine dithiocarbamnate)를 사용하여 극 미량 이온들을 착물로 형성시켜 농축한 다음, 전열 원자흡수 분광광도법으로 정량하였다. 이때 착물 형성을 위한 수용액의 pH와 착화제인 APDC의 양, 흡착을 위한 이온교환 수지의 종류 및 저어주는 시간, 역 분산에 사용하는 산의 종류 및 농도, 초음파 진동시간 등의 실험조건들을 최적화 하였다. 시료용액의 pH를 5로 조절하고 APDC의 양을 몰 비로 분석원소 전체의 430배 이상 첨가하여 코발트와 니켈을 정량적으로 착물을 형성시켰다. 이온교환 수지는 음이온 형태의 Dowex 2-X8이 우수하였다. pH를 조절한 시료용액, 리간드 및 수지 서스펜션을 혼합하고 1분간 저어주어 흡착을 완전하게 하였다. 역 분산을 위해서는 0.1 M 염산이 가장 좋았고, 이때 막 필터로 거른 교환 수지를 초음파 진동기에서 7분간 진동하면 충분하였다. 팔라듐을 염산과 함께 사용하면 매트릭스를 개선하여 재현성과 감도가 개선되었다. 바탕흡수 신호표준편차의 세배에 해당하는 검출한계는 Co 0.36 ng/mL, Ni 0.27 ng/mL로 극미량 검출이 가능하였고 시료에 일정량 첨가한 분석원소의 회수율은 각각 99-102%와 100-105% 이었다.

  • PDF

Dithiocarbamate 금속착물의 용매추출 및 분석적 응용(제 1 보). 해수중 흔적량 비스무트, 카드뮴, 인듐의 용매추출 및 정량 (Studies on Solvent Extraction and Analytical Applications of Metal-Dithiocarbamate Complexes(Ⅰ). Extraction and Determination of Trace Bismuth, Cadmium and Indium in Sea Water)

  • 전문교;최종문;최희선;김영상
    • 대한화학회지
    • /
    • 제40권7호
    • /
    • pp.492-500
    • /
    • 1996
  • Ammonium pyrrolidine dithiocarbamate(APDC)를 착화제로 사용하여 해수중 흔적량 비스무트, 카드뮴, 인듐을 동시에 용매추출하여 정량하는 방법을 연구하였다. 최적조건을 찾기위하여, 시료용액의 pH, 착화제의 양, 흔들어주는 시간, 유기용매의 종류 등에 대하여 조사하였고 역추출효율도 검토하였다. 해수시료 200mL를 취하여, pH를 4.0으로 조정하고 1% APDC 5.0mL를 첨가하고, MIBK 10.0mL로 35분 동안 흔들어 추출한다. 그리고 0.05M 수산화나트륨용액 10mL로 유기층의 HPDC를 세척한다. 유기층을 150.mu.g/mL Pd(II)를 포함하는 4M 질산으로 5분동안 흔들어 분석원소를 역추출한다. 팔라윰이 포함된 4M질산은 역추출효율을 증가시키고 흡광도 측정에서 매트릭스를 개선하여 감도를 증가시켰다. 바탕 흡광도에 대한 표준편차의 3배에 해당하는 농도로서의 검출한계는 Bi(III) :0.038, Cd(II) : 0.0057, In(III) : 0.023 ng/mL이었다. 동해 시료2 가지를 취하여 본방법으로 정량한 결과 Bi(III), In(III)은 검출한계 이하였고, Cd(II)는 0.018과 0.016 ng/mL이었다. 해수시료에 일정량 원소를 가해서 구한 회수율은 모두 90% 이상으로 아칼리금속 매트릭스에서 흔적량 원소의 동시분석에 이 방법이 응용될수 있음을 알 수 있었다.

  • PDF

NEWS&NEWS

  • 대한치과의사협회
    • 대한치과의사협회지
    • /
    • 제44권4호통권443호
    • /
    • pp.216-217
    • /
    • 2006
  • PDF