• Title/Summary/Keyword: APD array

Search Result 7, Processing Time 0.022 seconds

Development of Retina Photographing and Multi Channel Image Acquisition System for Thickness Measurement of Retina (망막 두께 측정을 위한 망막 촬영 및 다채널 영상획득장치 개발)

  • 양근호
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2004
  • In order to measure the retina thickness, the retina photographing system and the multi-channel high speed image data acquisition system is developed. This system requires the optical processing techniques and the high speed image processing techniques. The HeNe laser beam is projected the retina in artificial eye and then we sensed the reflected laser signal using APD array. The laser projection system on retina using optical instruments is implemented. In order to project the plane laser beam on retina, laser photographing system used the polygon mirror for horizontal scanning and the galvano mirror for vertical scanning. We acquired retina images in each channel of APD array, transferred computer using PCI interface the image data after real-time A/D converting.

  • PDF

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

Development of Retina Photographing System and 16 Channels Image Acquisition System (망막 촬영 장치 및 16 채널 영상 획득 장치 개발)

  • 양근호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.96-101
    • /
    • 2004
  • In order to measure the retina thickness, there are to need the 3-D retina photographing and the high speed signal processing system. In this paper, we introduced the retina photographing system and the 16-channel high speed image data acquisition system. There are able to measure the retina thickness with sensing image the returned laser signal to APD sensor after there were projected the HeNe laser on retina. We developed the laser projection system to sense a reflected image of the retina using APD sensor, the 16-channel high speed A/D converter and PCI master interface card for image transmission into computer.

3-Dimensional LADAR Optical Detector Development in Geiger Mode Operation (Geiger Mode로 동작하는 3차원 LADAR 광수신기 개발)

  • Choi, Soon-Gyu;Shin, Jung-Hwan;Kang, Sang-Gu;Hong, Jung-Ho;Kwon, Yong-Joon;Kang, Eung-Cheol;Lee, Chang-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.4
    • /
    • pp.176-183
    • /
    • 2013
  • In this paper, we report the design, fabrication and characterization of the 3-Dimensional optical receiver for a Laser Detection And Ranging (LADAR) system. The optical receiver is composed of three parts; $16{\pm}16$ Geiger Mode InGaAs Avalanche Photodiode (APD) array device operated at 1560 nm wavelength, Read Out Integrated Circuit (ROIC) measuring the Time-Of-Flight (TOF) of the return signal reflected from target objects, a package and cooler maintaining the proper operational condition of the detector and control electronics. We can confirm that the LADAR system can detect the signal from a target up to 1.2 km away, and it showed low Dark Count Rate (DCR) of less than 140 kHz, and higher than 28%-Photon Detection Efficiency (PDE). This is considered to be the best performance of the $16{\pm}16$ FPA APD optical receiver for a LADAR system.

Proposed surface modeling for slip resistance of the shoe-floor interface

  • Kim, In-Ju
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1995.04a
    • /
    • pp.515-528
    • /
    • 1995
  • Slips and falls are the major causes of the pedestrian injuries in the industry and the general community throughout the world. With the awareness of these problems, the friction coefficients of the interface between floorings and footwear have been measured for the evaluation of slip resistant properties. During this measurement process, the surface texture has been shown to be substantially effective to the friction mechanism between shoe heels and floor surfaces under various types of walking environment. Roughness, either of the floor surface or shoe heels, provides the necessary drainage spaces. This roughness can be designed into the shoe heel but this is inadequate in some cases, especially a wear. Therefore, it is essential that the proper roughness for the floor surface coverings should be provided. The phenomena that observed at the interface between a sliding elastomer and a rigid contaminated floor surface are very diverse and combined mechanisms. Besides, the real surface geometry is quite complicate and the characteristics of both mating surfaces are continuously changing in the process of running-in so that a finite number of surface parameters can not provide a proper description of the complex and peculiar shoe - floor contact sliding mechanism. It is hypothesised that the interface topography changes are mainly occurred in the shoe heel surfaces, because the general property of the shoe is soft in the face of hardness compared with the floor materials This point can be idealized as sliding of a soft shoe heel over an array of wedge-shaped hard asperities of floor surface. Therefore, it is considered that a modelling for shoe - floor contact sliding mechanism is mainly depended upon the surface topography of the floor counterforce. With the model development, several surface parameters were measured and tested to choose the best describing surface parameters. As the result, the asperity peak density (APD) of the floor surface was developed as one of the best describing parameters to explain the ambiguous shoe - floor interface friction mechanism. It is concluded that the floor surface should be continuously monitored with the suitable surface parameters and kept the proper level of roughness to maintain the footwear slip resistance. This result can be applied to the initial stage of design for the floor coverings.

  • PDF

Outlier Detection from High Sensitive Geiger Mode Imaging LIDAR Data retaining a High Outlier Ratio (높은 이상점 비율을 갖는 고감도 가이거모드 영상 라이다 데이터로부터 이상점 검출)

  • Kim, Seongjoon;Lee, Impyeong;Lee, Youngcheol;Jo, Minsik
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.5
    • /
    • pp.573-586
    • /
    • 2012
  • Point clouds acquired by a LIDAR(Light Detection And Ranging, also LADAR) system often contain erroneous points called outliers seeming not to be on physical surfaces, which should be carefully detected and eliminated before further processing for applications. Particularly in case of LIDAR systems employing with a Gieger-mode array detector (GmFPA) of high sensitivity, the outlier ratio is significantly high, which makes existing algorithms often fail to detect the outliers from such a data set. In this paper, we propose a method to discriminate outliers from a point cloud with high outlier ratio acquired by a GmFPA LIDAR system. The underlying assumption of this method is that a meaningful targe surface occupy at least two adjacent pixels and the ranges from these pixels are similar. We applied the proposed method to simulated LIDAR data of different point density and outlier ratio and analyzed the performance according to different thresholds and data properties. Consequently, we found that the outlier detection probabilities are about 99% in most cases. We also confirmed that the proposed method is robust to data properties and less sensitive to the thresholds. The method will be effectively utilized for on-line realtime processing and post-processing of GmFPA LIDAR data.