• Title/Summary/Keyword: AHU

Search Result 59, Processing Time 0.019 seconds

Preoperative Levels of Matrix Metalloproteinase-7 and -9 and Tissue Inhibitor of Matrix Metalloproteinase-1 Relation to Pathologic Parameters in Bladder Carcinoma Patients

  • Gunes, Mustafa;Kemik, Ahu Serap;Pirincci, Necip;Gecit, Ilhan;Taken, Kerem;Yuksel, Mehmet Bilgehan;Kaba, Mehmet;Eryilmaz, Recep
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.873-876
    • /
    • 2013
  • Our aim was to test the hypothesis that preoperative serum levels of matrix metalloproteinase-7 (MMP-7) and -9 (MMP-9) and tissue inhibitor of matrix metalloproteinase (TIMP-1) levels correlate with pathological features. Serum levels of MMP-7, and MMP-9 and TIMP-1 were determined in 90 bladder cancer patients and 40 healthy controls using an enzyme linked immunosorbent assay. Preoperative serum MMP-7 and MMP-9 levels were significantly higher in cancer patients than control groups (p<0.001). In contast, serum TIMP-1 levels were lower (p<0.001). Alteration in MMP-7, and MMP-9, and TIMP-1 production may contribute to tumor angiogenesis and be associated with clinic-pathological features.

Developing Optimal Pre-Cooling Model Based on Statistical Analysis of BEMS Data in Air Handling Unit (BEMS 데이터의 통계적 분석에 기반한 공조기 최적 예냉운전 모델 개발)

  • Choi, Sun-Kyu;Kwak, Ro-Yeul;Goo, Sang-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.467-473
    • /
    • 2014
  • Since the operating conditions of HVAC systems are different from those for which they are designed, on-going commissioning is required to optimize the energy consumed and the environment in the building. This study presents a methodology to analyze operational data and its applications. A predicted operation model is to be produced through a statistical data analysis using multiple regressions in SPSS. In this model, the dependent variable is the pre-cooling time, and the independent variables include the power output of the supply air inverter during pre-cooling, the supply air set temperature during pre-cooling, the indoor temperature-indoor set temperature just before pre-cooling, supply heat capacity, and the lowest outdoor air temperature during non-cooling/non-heating hours. The correlation coefficient R2 of the multiple regression model between the pre-cooling hour and the internal/external factors is of 0.612, and this could be used to provide information related to energy conservation and operating guidance.

Study on operation characteristics of the cold air distribution systems with an ice storage tank (빙축열을 이용한 저온공조시스템 운전 특성 연구)

  • 염한길;박병규;고득용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.301-312
    • /
    • 1999
  • Experiments were carried out to evaluate performance of the cold air distribution systems with an ice storage tank in test room. Cold air distribution systems provide primary air for comfort conditioning or process cooling at coil discharge temperatures$4^{\circ}C$ to$11^{\circ}C$. The application of a cold air distribution system allows for the downsizing of air distribution equipment and central plant equipment when ice storage tank is used. The benefit of a cold air distribution system include a decrease in the floor-to-floor height, increase floor space, reduced building capital costs, reduced energy use and demand. The use of cold air distribution can result in the most cost effective system and is currently being implemented world wise as the new standard in air conditioning systems. In this study, the cold air distribution system is compared with the general ice storage system. Under the same cooling load conditions, experimental results show that the supply air volume of cold air distribution system decrease 38%, and decrease 45% flow rate of brine for the general ice storage system.

  • PDF

Synthesis and biological activity of 6'-phenylgriseofulvin as analogs of antibiotic griseofulvin (항진균성항생물질 griseofulvin 유도체인 6'-phenylgriseofulvin의 합성과 항균활성)

  • Ko, Byoung-Seob;Oritani, Takayuki;Yamashita, Kyohei
    • Applied Biological Chemistry
    • /
    • v.35 no.5
    • /
    • pp.395-398
    • /
    • 1992
  • In order to study the influence of a 6'-methyl group in ring C of griseofulvin ${\underline{(1)}}$ on the fungicidal activity, 6'-methyl group was replaced with a larger phenyl group as $({\pm})-6'-phenylgriseofulvin$ ${\underline{(3)}}$, $({\pm})-6'-epiphenylgriseofulvin$ ${\underline{(4)}}$, synthesized by a Diels-Alder cycloaddition. Their biological activities were examined against Botrytis allii (IFO 9430) and B. cinerea (AHU 9573). $({\pm})-6'-Phenylgriseofulvin $ ${\underline{(3)}}$ showed high activity in $25\;{\mu}g/disc$.

  • PDF

Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit (공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구)

  • Kim, Se-Young;Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jin-Ho;Kim, Myung-Joon;Kim, Tae-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.3
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.

Efficiency of Livestock Farming Wastewater Treatment by Trickling Filters (撒水濾床法에 依한 畜産廢水의 處理效果에 관한 연구)

  • Ahu, Soo Mi
    • Journal of Environmental Health Sciences
    • /
    • v.11 no.2
    • /
    • pp.17-27
    • /
    • 1985
  • The objectives of this study is to examine efficiency of swinery wastewater treatment by trickling filters' pilot plant. The results of this study are as follows: 1. The characteristics of sample. The BOD$_5$ was from 2,450 to 2,880mg/l, COD(KMnO$_4$ acid method) was from 910 to 1,064mg/l, and SS was from 920 to 990mg/l. The pH of influent was from 7.3 to 7.6, and the temperature of water was from 17.0$\circ$C to 22.5$\circ$C. 2. For experiment by recirculation, the BODs removal efficiency is 65.2% at recirculation ratio (r)=0, and 70.7% at r=1. The ramoval efficiency of this study is higher than NRC formula of U.S.A.. The recirculation is not significant effect on removal efficiency. 3. For experiment by hydraulic load, the BOD$_5$ removal rate decreased from 73.1% at $3.1m^3/m^2\cdot d$ to 65.3% at $9.2m^3/m^2\cdot d$. The design formula of this study which shows the removal rate of soluble BOD is $Le/Li =10^{-0.24} D/Q^{0.24}$ (Q: hydraulic load, D: depth of filter). 4. For experiment by organic load, the BOD$_5$ removal rate is increased from 70.2% at $0.77kg/m^3\cdot d$ to 75.4% at $4.28kg/m^3\cdot d$. We can obtain the straight line y=0.749 x (y: removed BOD, x :applied BOD) by the least squares method. 5. We can know that trickling filters is strong with the hydraulic load and the organic matter shock load. Here, we can judge that trickling filters is a good method for the treatment of swinery wastewater which containing high concentrated organic matter.

  • PDF

Investigation of bacteremia after toothbrushing in orthodontic patients

  • Hussein, Emad Ahmad;Acar, Ahu;Dogan, Alev Aksoy;Kadir, Tanju;Caldemir, Seniz;Erverdi, Nejat
    • The korean journal of orthodontics
    • /
    • v.39 no.3
    • /
    • pp.177-184
    • /
    • 2009
  • Objective: The aim of this study was to investigate the occurrence rate of bacteremia following toothbrushing with toothpastes composed of several antibacterial agents and compare the results with the conventional oral hygiene maintaining methods in orthodontic patients. Methods: This clinical study included 100 adult orthodontic patients who were divided into 4 groups. Each group comprised of 25 patients, wearing fixed orthodontic appliances. In the first group, bacteremia was assessed after toothbrushing without using any toothpaste. In the second group, a 0.2% chlorhexidine gluconate mouthrinse was used before brushing with no toothpaste. In the third group, subjects brushed with a commonly used toothpaste which did not include an additional antimicrobial agent. The fourth experimental group used toothpaste which included tea tree oil, clove oil, peppermint oil and bisabolol as antimicrobial elements. Pre- and post-brushing blood samples were obtained using a strict aseptic technique. All samples were microbiologically evaluated using blood culture bottles. Results: Toothbrushing in orthodontic patients yielded to an increase in the occurrence rate of bacteremia when using normal toothpaste or no toothpaste at all. Conclusions: The use of chlorhexidine mouthwash before toothbrushing, and brushing with antimicrobial toothpaste did not show a statistically significant difference in preventing the occurrence of bacteremia (p > 0.05).

Gingival crevicular fluid CSF-1 and IL-34 levels in patients with stage III grade C periodontitis and uncontrolled type 2 diabetes mellitus

  • Ahu Dikilitas;Fatih Karaaslan;Sehrazat Evirgen;Abdullah Seckin Ertugrul
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.455-465
    • /
    • 2022
  • Purpose: Periodontal diseases are inflammatory conditions that alter the host's response to microbial pathogens. Type 2 diabetes mellitus (T2DM) is a complex disease that affects the incidence and severity of periodontal diseases. This study investigated the gingival crevicular fluid (GCF) levels of colony-stimulating factor-1 (CSF-1) and interleukin-34 (IL-34) in patients with stage III grade C periodontitis (SIII-GC-P) and stage III grade C periodontitis with uncontrolled type 2 diabetes (SIII-GC-PD). Methods: In total, 72 individuals, including 24 periodontally healthy (PH), 24 SIII-GC-P, and 24 SIII-GC-PD patients, were recruited for this study. Periodontitis patients (stage III) had interdental attachment loss (AL) of 5 mm or more, probing depth (PD) of 6 mm or more, radiographic bone loss advancing to the middle or apical part of the root, and tooth loss (<5) due to periodontal disease. Radiographic bone loss in the teeth was also evaluated; grade C periodontitis was defined as a ratio of the percentage of root bone loss to age greater than 1.0. The plaque index (PI), gingival index (GI), presence of bleeding on probing (BOP), PD, and clinical AL were used for clinical periodontal assessments. GCF samples were obtained and analyzed using an enzyme-linked immunosorbent assay. Results: All clinical parameters-PD, AL, GI, BOP, and PI-were significantly higher in the SIII-GC-PD group than in the PH and SIII-GC-P groups for both the full mouth and each sampling site (P<0.05). The total IL-34 and CSF-1 levels were significantly higher in the SIII-GC-PD group than in the PH and SIII-GC-P groups (P<0.05), and there were significant differences between the periodontitis groups (P<0.05). Conclusions: These findings suggest that IL-34 and CSF-1 expression increases in patients with SIII-GC-PD. CSF-1 was associated with the inflammatory status of periodontal tissues and T2DM, while IL-34 was associated only with T2DM.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.