• Title/Summary/Keyword: AH Tau

Search Result 12, Processing Time 0.016 seconds

Reproducibility of Adenosine Tc-99m sestaMIBI SPECT for the Diagnosis of Coronary Artery Disease (관동맥질환의 진단을 위한 아데노신 Tc-99m sestaMIBI SPECT의 재현성)

  • Lee, Duk-Young;Bae, Jin-Ho;Lee, Sang-Woo;Chun, Kyung-Ah;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Ha, Jeoung-Hee;Chae, Shung-Chull;Lee, Kyu-Bo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.473-480
    • /
    • 2005
  • Purpose: Adenosine myocardial perfusion SPECT has proven to be useful in the detection of coronary artery disease, in the follow up the success of various therapeutic regimens and in assessing the prognosis of coronary artery disease. The purpose of this study is to define the reproducibility of myocardial perfusion SPECT using adenosine stress testing between two consecutive Tc-99m sestaMIBI (MIBI) SPECT studies in the same subjects. Methods: Thirty patients suspected of coronary artery disease in stable condition underwent sequential Tc-99m MIBI SPECT studies using intravenous adenosine. Gamma camera, acquisition and processing protocols used for the two tests were identical and no invasive procedures were performed between two tests. Mean interval between two tests were 4.1 days (range: 2-11 days). The left ventricular wall was divided into na segments and the degree of myocardial tracer uptake was graded with four-point scoring system by visual analysis. Images were interpretated by two independent nuclear medicine physicians and consensus was taken for final decision, if segmental score was not agreeable. Results: Hemodynamic responses to adenosine were not different between two consecutive studies. There were no serious side effects to stop infusion of adenosine and side effects profile was not different. When myocardial uptake was divided into normal and abnormal uptake, 481 of 540 segments were concordant (agreement rate 89%, Kappa index 0.74). With four-grade storing system, exact agreement was 81.3% (439 of 540 segments, tau b=0.73). One and two-grade differences were observed in 97 segments (18%) and 4 segments (0.7%) respectively, but three-grade difference was not observed in any segment. Extent and severity scores were not different between two studios. The extent and severity scores of the perfusion defect revealed excellent positive correlation between two test (r value for percentage extent and severity score is 0.982 and 0.965, p<0.001) Conclusion: Hemodynamic responses and side effects profile were not different between two consecutive adenosine stress tests in the same subjects. Adenosine Tc-99m sestaMIBI SPECT is highly reproducible, and could be used to assess temporal changes in myocardial perfusion in individual patients.

Comparison of Regional Myocardial Perfusion, Left Ventricular Volume and Ejection Fraction between 8- and 16-Frame Gated SPECT (8-단위영상과 16-단위영상으로 얻은 게이트 심근관류 스펙트에서 국소 심근관류, 좌심실 용적과 구혈률의 비교)

  • Lee, Sang-Woo;Lee, Jae-Tae;Bae, Jin-Ho;Jeong, Shin-Young;Chun, Kyung-Ah;Ha, Jeoung-Hee;Ahn, Byeong-Cheol;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.269-277
    • /
    • 2003
  • 목적: 게이트 심근관류 스펙트는 심근의 관류와 좌심실 기능을 동시에 평가할 수 있는 유용한 방법이다. 현재, 게이트 영상 획득시 8 단위영상이 널리 사용되지만, 아직 가장 적절한 단위영상의 수에 대해서는 논의의 여지가 있다. 본 연구는 동일한 환자에서 8 단위영상과 16 단위영상으로 게이트 심근관류 스펙트를 2회 연속적으로 시행하여 국소적 심근관류, 좌심실 용적과 구혈률등을 비교하였다. 대상 및 방법: 42명(평균 연령: 55세, 남: 녀=26: 16)의 관상동맥 질환이 의심되거나 알려진 환자를 대상으로 안정시 Tc-99m MIBI를 이용한 게이트 스펙트를 8 단위영상과 16 단위영상으로 2회 연속하여 시행하였다. 좌심실의 확장기말 용적, 수축기말 용적과 구혈률을 각각 얻었으며 확장기말의 단층영상을 18 분절로 나누고 각 분절마다 심근의 관류정도를 4등급으로 나누어 국소적 심근관류를 평가하였다. 결과: 8 단위영상과 16 단위영상 게이트 스펙트에서 국소적 심근관류의 일치도는 85.7% (tau-b=0.786, p<0.001)로 우수하였다. 두 방법간에 1등급의 차이는 100 분절(13.2%), 2등급 차이는 8 분절(1.1 %)이 있었고 3등급 차이는 없었다. 좌심실의 확장기말 용적, 수축기말 용적, 구혈률은 두 방법간에 높은 상관성을 보였으며(r=0.993, 0.989, 0.935), 좌심실 구혈률은 8 단위영상을 사용할 때 평균 1.8% 낮게 측정되어 통계적인 유의성은 있었으나(p<0.05), 그 차이는 크지 않았다. 결론: 8 단위영상과 16 단위영상을 사용한 게이트 심근관류 스펙트에서 국소적 심근관류의 일치도는 우수하였으며, 좌심실의 기능적 계수의 차이도 크지 않았다. 비록 높은 단위영상을 사용했을 때 더 정확하고 자세한 정보를 얻을 수 있다 하더라도, 구혈률과 용적 등을 얻는 일상적인 임상검사에는 8 단위영상 또한 그 역할을 충분히 할 수 있을 것으로 사료된다.