• Title/Summary/Keyword: AFDD

Search Result 3, Processing Time 0.022 seconds

Arc Detection Method using RSSI Signal to High Frequency Noise (고주파 노이즈의 RSSI신호를 이용한 Arc검출방법)

  • Yang, Seung Kook;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.102-106
    • /
    • 2015
  • In order to avoid the electrical fire, AFCI(Arc Fault Cirruit Interrupter) has been obligated to be adopted in the United States of America since 2002. A study was carried out on how to detect Arc. In this paper, The propose is high-frequency signal detection methods and RSSI(Received Signal Strength Indication) signal processing algorithm for Arc detection. and the electrical characteristics were verifying.

Stage correction during freezing season using artificial neural network (인공신경망 기법을 이용한 결빙기 수위 보정)

  • Jeong, Han-Seok;Kim, Hak-Kwan;Kang, Moon-Seong;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.880-880
    • /
    • 2012
  • 수위-유량자료는 수문모형의 적용 등과 같은 다양한 수자원분야에서 기초적인 관측자료로서 이용되고 있다. 하지만 겨울철 결빙에 따른 수위계의 오작동과 제한된 실측 수위자료에 따른 수위 자료의 보정과 획득에 어려움을 겪고 있다. 본 연구에서는 수자원 분야에서 다양하게 적용된 바 있는 인공신경망 기법과 누적결빙온도일 (AFDD; Accumulated Freezing Degree Days) 개념을 이용하여 오산천 유역의 탑동수위관측점의 결빙기 수위자료를 보정하였다. 연구결과 보정된 수위자료는 강우량과 방류량 등의 영향을 비교적 잘 반영하는 것으로 나타났으며 향후 지속적인 연구를 통해 인공신경망을 이용한 수위 보정 결과를 검정할 수 있어야 할 것이다.

  • PDF

A study on working out arc detector related regulations (아크 검출기 관련 규정 마련에 관한 연구)

  • Park, Yong-Seo
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.115-122
    • /
    • 2018
  • More than 70% of the electric fire cases happen in this country are caused by arc. This paper aims to prepare measures of preventing electric fires resulted from arc by analyzing the technical standards and related regulations on the existing circuit breaker. Based on the study, we concluded that the technical and legal standards of the arc detector should be separately regulated from those of existing circuit breaker, considering the characteristics of arc detectors. Accordingly, we suggested in this paper that the arc detector related regulations should either be added to the existing circuit breaker related regulations, or to be handled separately. For effective prevention of electric fires caused by arc, it is urgently required to install arc detector and it is, therefore, appropriate to make it mandatory to install an arc detector. Under the given circumstance, it is suggested that the arc detector related regulations should be added to the existing regulations for the circuit breaker. The technical standards of arc detectors should reflect the arc judgement specification, breaking threshold of arc and the range of unnecessary signal that breaker should not react to respond.