• Title/Summary/Keyword: AE Peak Voltage

Search Result 5, Processing Time 0.024 seconds

Location and Frequency Domain Detection of Corona Discharge Point in Oil Using AE Sensor (AE센서를 이용한 유중 코로나방전점 위치 및 주파수 영역 검출)

  • 이상우;김성훈;김인식;김기채;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.127-131
    • /
    • 1999
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane electrode was analyzed to determine the proper ultrasonic sensor. We also examined the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] AC high-voltage in oil. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were found to be 130[kHz] by the fast fourier transform. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages. Also the detection of corona discharge point location by AE signals was found to be possible by using two sensors.

  • PDF

Evaluation of Fracture Strength of WA-Vitrified and Resinoid Bond Grinding Wheels by Acoustic Emission (AE에 의한 WA계 비트리파이드 및 레지노이드 結合劑硏削숫돌의 破壞强度評價)

  • 강명순;한응교;권동호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.241-251
    • /
    • 1988
  • The purpose of this paper is to evaluate fracture strength of WA-vitrified and resinoid bond grinding wheels by means of acoustic emission. The paper conducts tension test, compression test, splitting tensile test and bending test with AE measuring system. These tests have been carried out in accordance with the grain sizes and grades of grinding wheels. The fracture strength of grinding wheels is evaluated by the clarification of biaxal fracture criterion of Babel and Sines. It clarifies the influence of factors of grinding wheel upon AE characteristics and evaluates the predictability of life of grinding wheels and the perception of fracture.

Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor (광대역 AE 센서에 의한 유중코로나의 초음파 특성)

  • Kim, In-Sik;Lee, Sang-U;Lee, Dong-In;Lee, Gwang-Sik;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF

The New Type Pulse Generator Adopted Cascading Technique (소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성)

  • Kyung-Ae Shin;Whi-Young kim;Myeong-Soon Kim
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.3
    • /
    • pp.363-368
    • /
    • 2001
  • This paper introduced cascading technique as a new technology composed of two pulse transformers and presented the experimental data and results. To obtain the stable pulse voltage adopted cascading technique, we designed and tested a compact pulse generator by adjusting the load resistors and input voltage. Adopting cascading technique to load, we found that average cascading voltage was about 62$\%$ of theoretical value. Cascading ratio was calculated at almost 19 compared with non cascading voltage.

  • PDF

Comparison Study of AAS and ISE Method in the Lithium Analysis of Serum and Urine (혈액 및 소변의 Lithium치 측정에 있어서 AAS법과 ISE법의 비교)

  • Lee, Soo-In;Lee, Chae-Hoon;Kim, Kyung-Dong;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.409-416
    • /
    • 1993
  • In the method for lithium (Li) analysis, flame emission photometry and atomic absorption spectrophotometry (AAS) have been used most frequently. In addition, lithium can be analyzed by ion-selective electrode (ISE) or fluorscence polarization immunoassay. We evaluated the comparison between AAS method based on the principle of absorption of light at 670.8 nm by Li and ISE method based on the principle of voltage difference generated by Li in contact with lithium ionophore. We compared with those obtained by AAS (AA/AE Spectrophotometer 551, Instrumentation Laboratory Co.) and ISE(CSYNCHRON EL-ISE, Beckman Co.) in the serum and urine of 6 patients and evaluated time-related changes of serum lithium concentration after dosing in both methods. The results are summarized as follows : 1. In within-run precision study for lithium concentration, coefficient variations (CVs, %) ranged from 1.34 to 2.17 for AAS and from 0.34 to 0.85 for ISE method. In between-run precision study for lithium concentration, CVs ranged from 1.23 to 1.72 for AAS and from 0.61 to 1.38 for ISE method. 2. The correlation study between AAS and ISE method resulted in Y=0.946X+0.137 (N=32, r=0.933, X=AAS, Y=ISE) for serum lithium and Y=1.092X+0.977 (N=28, r=0.943, X=AAS, Y=ISE) for urine lithium. 3. Time-related changes of serum lithium concentration in both AAS and ISE method resulted in peak serum levels about 2 hours after dosing and then rapidly decreased after the peak serum level and finally arrived at nearly initial levels about 9 hours after dosing. 4. The reference range of serum lithium was found as undetectable level for both AAS and ISE method and the reference range of urine lithium to the urine creatinine was 0-0.00014 mmol/mg(mean 0.00002 mmol/mg) for AAS method.

  • PDF