• Title/Summary/Keyword: AE Energy

Search Result 544, Processing Time 0.031 seconds

Dynamic mechanism of rock mass sliding and identification of key blocks in multi-fracture rock mass

  • Jinhai Zhao;Qi Liu;Changbao Jiang;Zhang Shupeng;Zhu Weilong;Ma Hailong
    • Geomechanics and Engineering
    • /
    • v.32 no.4
    • /
    • pp.375-385
    • /
    • 2023
  • There are many joint fissures distributed in the engineering rock mass. In the process of geological history, the underground rock mass undergoes strong geological processes, and undergoes complex geological processes such as fracture breeding, expansion, recementation, and re-expansion. In this paper, the damage-stick-slip process (DSSP), an analysis model used for rock mass failure slip, was established to examine the master control and time-dependent mechanical properties of the new and primary fractures of a multi-fractured rock mass under the action of stress loading. The experimental system for the recemented multi-fractured rock mass was developed to validate the above theory. First, a rock mass failure test was conducted. Then, the failure stress state was kept constant, and the fractured rock mass was grouted and cemented. A secondary loading was applied until the grouted mass reached the intended strength to investigate the bearing capacity of the recemented multi-fractured rock mass, and an acoustic emission (AE) system was used to monitor AE events and the update of damage energy. The results show that the initial fracture angle and direction had a significant effect on the re-failure process of the cement rock mass; Compared with the monitoring results of the acoustic emission (AE) measurements, the master control surface, key blocks and other control factors in the multi-fractured rock mass were obtained; The triangular shaped block in rock mass plays an important role in the stress and displacement change of multi-fracture rock mass and the long fissure and the fractures with close fracture tip are easier to activate, and the position where the longer fractures intersect with the smaller fractures is easier to generate new fractures. The results are of great significance to a multi-block structure, which affects the safety of underground coal mining.

An Evaluation of Tensile Characteristics of the Stress Aging Heat-treated SM45C Steel by Acoustic Emissions (음향방출법에 의한 SM45C 응력시효 처리재의 인장특성 평가)

  • Rhee, Zhang-Kyu;Park, Bog-Nam
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.413-421
    • /
    • 2009
  • This paper investigates tensile characteristics of the stress aging heat-treated SM45C steel which are aging temperature at $250^{\circ}C$, $300^{\circ}C$, aging time at 1, 3 hours, and applied load at 300, 400N conditions by using acoustic emission. Most suitable aging condition was aging temperature $300^{\circ}C$, aging time 1 hour, and aging applied load 300N. And increased yield load 28.3% than non-treatment specimen in this condition. AE energy in elastic limit increased about 16.7 times than non-treatment specimen. When aging time is 3 hours, yield load decreased than other conditions that possibility is high to have itself defect on inside the specimen or coarse grain size precipitation is different in happened over-aging phenomenon. Especially, in case of $300^{\circ}C$, 3 hours and 400N condition appeared AE energy in elastic limit fairly high about 30 times than non-treatment specimen. This is considered by emit a lot of energies when material causes plastic deformation because the ductility increases on specimen by over-aging phenomenon.

  • PDF

Fatigue damage monitoring and evolution for basalt fiber reinforced polymer materials

  • Li, Hui;Wang, Wentao;Zhou, Wensong
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.307-325
    • /
    • 2014
  • A newly developed method based on energy is presented to study the damage pattern of FRP material. Basalt fiber reinforced polymer (BFRP) is employed to monitor the damage under fatigue loading. In this study, acoustic emission technique (AE) combined with scanning electronic microscope (SEM) technique is employed to monitor the damage evolution of the BFRP specimen in an approximate continuous scanning way. The AE signals are analyzed based on the wavelet transform, and the analyses are confirmed by SEM images. Several damage patterns of BFRP material, such as matrix cracking, delamination, fiber fracture and their combinations, are identified through the experiment. According to the results, the cumulative energy (obtained from wavelet coefficients) of various damage patterns are closely related to the damage evolution of the BFRP specimens during the entire fatigue tests. It has been found that the proposed technique can effectively distinguish different damage patterns of FRP materials and describe the fatigue damage evolution.

Study on the Multi-measuring Method for Evaluation of Internal Leak of Power Plant Valve (발전용 밸브누설 평가를 위한 다중계측 연구)

  • Lee, S.G.;Park, S.K.;Park, J.H.;Kim, K.H.;Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • Leak would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leak at present are analysis of ${\Delta}T$, AE(Acoustic Emission) analysis, and thermal image. The result for test of secondary system in nuclear power plant Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leak is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So we think that using the Multi-Measuring method is more sound judgment than single-measuring method.

  • PDF

Effect of substrate pretreatment on the growth yield enhancement and growth temperature decrease of carbon nanotubes (탄소나노튜브의 합성수율 증대와 저온 합성에 미치는 기판 전처리의 영향)

  • Shin, Eui-Chul;Jo, Sung-Il;Jeong, Goo-Hwan
    • Journal of Industrial Technology
    • /
    • v.39 no.1
    • /
    • pp.7-14
    • /
    • 2019
  • Carbon nanotubes (CNT) on metal substrates are definitely beneficial because they can maintain robust mechanical stability and high conductivity between CNT and metal interfaces. Here, we report direct growth of CNT on Ni-based superalloy, Inconel 600, using thermal chemical vapor deposition (CVD) with acetylene feedstock in the growth temperature range of $400-725^{\circ}C$. Furthermore, we studied the effect of substrate pretreatment on the growth yield enhancement and growth temperature decrease of CNT on Inconel 600. Activation energy (AE) for CNT growth was estimated from the CNT height change with respect to the growth temperature. The AE values significantly decreased from 205.03 to 24.35 kJ/mol by the pretreatment of thermal oxidation of Inconel substrate at $725^{\circ}C$ under ambient. Higher oxidation temperature tends to have lower activation energy. The results have shown the importance of pretreatment temperature on CNT growth yield and growth temperature decrease.

Effects of water saturation time on energy dissipation and burst propensity of coal specimens

  • Yang, Xiaohan;Ren, Ting;Tan, Lihai;Remennikov, Alex
    • Geomechanics and Engineering
    • /
    • v.24 no.3
    • /
    • pp.205-213
    • /
    • 2021
  • Water infusion has long been taken as an effective way to eliminate coal burst risk as coal properties can be loosen and soften by water infusion. However, not all industrial trials of water infusion for coal burst prevention have been necessarily effective in all situations as the effectiveness of this method can be affected by water infusion time, coal properties and the parameters of water injection. Hence, some fundamental issues including the effects of water infusion time on burst propensity and energy evolution need to be further discussed. In this paper, four groups of coal specimens with 0 day, 5 days, 10 days, and 15 days water saturation time are tested under uniaxial compression load with the application of AE monitoring. To comprehensively compare the burst behavior of coal specimens under different water saturation time, stress-strain curves, AE counts, fragmentation characteristics and burst propensity of these groups are analyzed. It was found by this research that sufficient water saturation can mitigate the burst behavior of coal samples while insufficient water infusion might cannot reach the burst mitigation aims.

Studies on Energy Expenditure of Korean Service Personnel (한국인(韓國人) 서어비스업(業) 종사자(從事者)의 대사량(代謝量)에 관(關)한 연구(硏究))

  • Kim, Ae-Ju
    • The Korean Journal of Physiology
    • /
    • v.4 no.2
    • /
    • pp.69-81
    • /
    • 1970
  • These studies were carried out on 176 persons ranging in age from 20 to 50 years to determine the basal metabolic rates, energy expenditure of various activities, and daily energy expenditure of service personnel in Korea. The measurements of basal metabolic rates were made on 42 subjects by indirect calorimetry using a Douglas' bag and Scholander's gas analyzer. The energy expenditures of various activities of daily life were also measured. The greatest increase in ratio of energy expenditure in the basis of resting metabolism was 277.3% in floor sopping and the least was 40.9% during hair cutting by beauticians. The assessment of the dailly energy expenditure for each subject was made by the factorial method, using a record of their activities throughout each of 24 hours of every survey day. Certain activities were recorded in minute units. The total daily energy expenditure is the sum of all energy expenditure. This was calculated by multiplying the caloric value of the metabolic rate by the time spent on each activity. The result of the total daily energy expenditure records for 17 occupations are summarized. In respect to the daily energy expenditure, most of the occupations are moderate or light work. But the janiter (F), laundress, cook (F), room maid and nurse's aid do heavy work.

  • PDF

Study on the effect of reducing consumption of domestic electric power by managing model energy mileage system in Busan (부산시 에너지마일리지제 시범운영을 통한 가정용 전력 소비절감 효과분석)

  • Lee, Eun-Ju;Pae, Min-Ho;Kim, Jae-Min;Song, Gook-Sup;Kwak, Ro-Yeul;Ok, Sung-Ae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.934-939
    • /
    • 2009
  • To promote citizen's involvement in the GHG(Green House Gas) reduction policy, Busan city administration adopted an pilot energy incentive system called 'energy mileage'. The energy mileage system was designed to make energy end-users motivated to reduce domestic electricity use by providing financial rewards. Through the course of the pilot period, 5,3330 householders volunteerly participated the pilot system. About 66% of the participants managed to make energy saving against the same period of the previous year while 38.8% achieved the targeted reduction rate(i.e. over 10%) and received the equivalent rewards.

  • PDF

Estimation Method of Energy Consumption by End-Use in Office Buildings based on the Measurement Data (계측데이터를 이용한 업무시설에서의 에너지용도별 사용량 추정방법 연구)

  • Kim, Sung-Im;Yang, In-Ho;Ha, Soo-Yeon;Lee, Soo-Jin;Jin, Hye-Sun;Suh, In-Ae;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.165-176
    • /
    • 2020
  • The purpose of this study is to develop a estimation method of energy consumption by end-use in office buildings. For this, the current status of information on building energy use was investigated, and the domestic and foreign literature on the classification of energy use in non-residential buildings and the estimation method of energy use were reviewed. In addition, the characteristics of energy consumption by end-use were analyzed with measurement data of 48 office buildings in Seoul. As results, the annual and monthly estimation method of energy consumption by end-use in office buildings using public and measurement data was presented, and the applicability of the estimation method was examined by applying to sample office buildings.

${\gamma}$-FIB를 이용한 산소 유량에 따른 ITO (Indium Tin Oxide)의 Energy Band Structure 측정

  • Lee, Gyeong-Ae;Kim, Dong-Hae;Gwon, Gi-Cheong;Eom, Hwan-Seop;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.191-191
    • /
    • 2011
  • 최근 투명전극 연구는 태양전지 및 디스플레이, LED 등 많은 분야에서 응용되며 또한 기술 개발이 활발하다. 그 중 전기 전도도가 우수하면서 밴드갭이 2.5 eV 이상으로 가시광 영역에서 투명하기 때문에 디스플레이의 투명전극으로 ITO (Indium Tin Oxide)가 많이 사용되고 있다. 본 실험에서는 RF magnetron sputtering법을 이용한 ITO의 증착시 산소 유량을 달리하여 제작한 박막의 Energy Band Structure를 ${\gamma}$-FIB system을 이용하여 측정하였다. ITO에 이온화 에너지가 24.5 eV인 He Ion source를 주사하였을 때 Auger self-convolution을 통해 이차전자의 운동 에너지 분포를 구하고, 이를 통해 ITO 내의 Energy Band Structure를 실험적으로 측정하였다.

  • PDF