• Title/Summary/Keyword: AE 에너지

Search Result 255, Processing Time 0.03 seconds

Monitoring Technique using Acoustic Emission and Microseismic Event (AE와 MS 이벤트를 이용한 계측기술)

  • Cheon, Dae-Sung;Jung, Yong-Bok;Park, Chul-Whan;Synn, Joong-Ho;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Acoustic emission (AE) and Microseimsic (MS) activities are law-energy seismic events associated with a sudden inelastic deformation such as the sudden movement of existing fractures, the generation of new fractures or the propagation of fractures. These events rapidly increase before major failure and happen within a given rock volume and radiate detectable seismic waves. The main difference between AE and MS signals is that the seismic motion frequencies of AE signals are higher than those of MS signals. As the failure of geotechnical structures usually happens as a high velocity and small displacement, it is nat easy ta determine the precursor and initiation stress level of failure in displacement detection method. To overcame this problem, AE/MS techniques far detection of structure failure and damage have recently adapt in civil engineering. This study deal with the basic theory of AE/MS and state of arts in monitoring technique using AE/MS.

A Study on AE Signal Analysis of Composite Materials Using Matrix Piezo Electric Sensor (매트릭스형 피에조센서를 이용한 복합재료 AE신호 분석에 관한 연구)

  • Yu, Yeun-Ho;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on non-destructive testing methods has become an important research area for improving their reliability and safety. AE (acoustic emission) can evaluate the defects by detecting the emitting strain energy when elastic waves are generated by the initiation and growth of crack, plastic deformation, fiber breakage, matrix cleavage, or delamination. In the paper, AE signals generated under uniaxial tension were measured and analyzed using the $8{\times}8$ matrix piezo electric sensor. The electronic circuit to control the transmitting distance of AE signals was designed and constructed. The optical data storage system was also designed to store the AE signal of 64channels using LED (light emitting diode) elements. From the tests, it was shown that the source location and propagation path of AE signals in composite materials could be detected effectively by the $8{\times}8$ matrix piezo electric sensor.

Iliacus Muscle Rupture with Associated Partial Femoral Nerve Palsy during Soccer Game - Case Report - (축구 경기 중 발생한 장골근 파열과 부분 대퇴 신경 마비 - 증례보고 -)

  • Jung, Sung-Hoon;Lee, Sang-Ho;Song, Kyeong-Seop;Park, Byeong-Mun;Ki, Chul Hyun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.2
    • /
    • pp.92-95
    • /
    • 2012
  • Iliacus muscle tears are a rare injury seen after the high-energy trauma or as a result of low-energy injuries in patients with a bleeding diathesis as coagulopathy, receiving anticoagulation therapy and hemophiliac. Femoral nerve palsy due to compression from a hematoma by iliacus muscle rupture are rarely reported. Routine evaluation includes MRI to confirm and define the pathologic abnormality supplemented by EMG and nerve conduction studies to evaluate patterns and extent of femoral nerve injury. Hematologic evaluation for bleeding diathesis may preceded, if suspicion of coagulopathy is present. We report the case of a healthy 32-year-old male with iliacus rupture and concomitant femoral nerve palsy sustained by kicking motion during soccer game. After 6 months of observation with non-operative treatment regimen, satisfactory results were obtained, so we report it with a review of the literatures.

  • PDF

Wear Characteristic of Diamond Burs in Dentistry (치과용 다이아몬드 버의 마멸 특성)

  • 이근상;임영호;권동호;최만용;김교한;최영윤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.80-84
    • /
    • 1996
  • This paper aims at reviewing the Possibility application over normal or abnormal, detection used by AE and the wear characteristics of grinding process. In this study, when diamond bur in dentistry with chosen grinding conditions were tuned at grinding. The variation of grinding resistance and hE signal is detected by the use of AE measuring system. The tests are carried out in accordance with diamond burs and workpiece; arcyl and bovine. According to the experiment results, the following can be expected; AE has the possibility to detect the state normality and abnormality. However, the grinding resistance measuring can find it difficult to detect it. It can be accurately excerpted from AE occurrence pattern in contact start point of diamond bur and bovine, grinding condition and derailment point. It is known that AE$\_$rms/ is well compatible with grinding resistance. According to the increase of the material removal rate, the specific energy of the diamond bur is inclined to decrease and the grinding resistance has a tendency to increase.

  • PDF

Grinding Characteristics of Diamond Burs in Dentistry (치과용 다이아몬드 버의 연삭가공 특성)

  • Lee, Keun-Sang;Lim, Young-Ho;Kwon, Dong-Ho;Choi, Man-Yong;Kim, Kyo-Han;Choi, Young-Yun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.12
    • /
    • pp.66-72
    • /
    • 1997
  • This paper aims at reviewing the possibility application over normal or abnormal, detection used by AE and the wear characteristics of grinding process. In this study, when diamond bur in dentistry with chosen grinding conditions were tuned at grinding. The variation of grinding resistance and AE signal is detected by the use of AE measuring system. The tests are carried out in accordance with diamond burs and workpiece: arcyl and bovine. According to the experiment results, the following can be expected: AE has the possibility to detect the state normality and abnormality. Hpwever, the grinding resistance measuring can find it difficult to detect it. It can be accurately excepted from AE occurrence pattern in contact start point of diamond bur and bovine, grinding condition and derailment point. It is known that AErms is well compatible with grinding resistance. According to the increase of the material removal rate, the specific energy of the diamond bur is inclined to dectease and the grinding resistance has a tendency to increase.

  • PDF

이온주입 에너지에 따른 Auger Si KLL Peak Shift 및 Ti 계열 화합물의 Chemical State 관찰

  • Heo, Sung;Park, Yoon-Baek;Min, Gyung-Yeol;Lee, Sun-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.83-83
    • /
    • 1999
  • 본 연구에서는 Auger Elecrtron Spectroscopy (AES) 장비를 이용하여 Silicone Wafer 표면에 BF 이온을 주입시킨 후 Dopping 농도 및 Implantation 에너지에 따른 Si KLL Peak의 변화를 관찰하였다. 또한 PVD Ti 계열 화학물의 시료에 대하여 Peak의 Shape 변화를 관찰하였다. 1)Dopping 농도 및 Implantation 에너지에 따른 Si KLL Peak의 변화 관찰 일반적으로 Silicone 기판에 Arsenic(3가)을 Dopping 하였을 경우, Si KLL Peak의 Kinetic Energy 값은 순수 Si Peak보다 더 작은 값으로 Shift 하며, Boron (5가)을 Dopping하였을 경우에는 더 큰 값으로 Shift 한다. 이론적으로 N-type Si의 에너지 차이는 약 1.0eV로 보고되어 있으며, AES를 이용하여 실험적으로 측정된 값은 약 0.6eV정도로 알려져 있다. 이러한 차이는 Dopping 농도에 따라 Valance Band의 에너지 값이 변화하기 때문이라고 알려져 있다. 본 연구에서는 BF2를 Si에 이온 주입하여 입사 에너지 및 dose 량에 따른 Si KLL Peak의 변화를 관찰하였다. 그림1과 같이 Si KLL Peak는 Implantation Energy가 작을수록 Kinetic Energy가 높은 곳으로 Shift 한다. 이는 LOw Energy로 이온 주입하면, Projected Range (Rp)가 High Energy로 이온 주입할 때보다 작기 때문이며, 이 결과를 Secondary Ion Mass Spectroscopy (SIMS) 및 TRIM simulation을 이용하여 확인하였다. 또한 표면에서의 전자 Density의 변화와 Implantation energy와의 관계를 시료의 표면에서 반사되어 나오는 전자의 에너지 손실(Reflected Electron Energy Loss Spectroscopy:REELS)을 통하여 고찰하였다. 2) PVD Ti 계열화합물의 시료에 대한 peak의 shape 가 변화하며, TiL3M23V (Ti2) 및 TiL3M23M23 (Til) Peak의 Intensity Ratio가 변화한다. 따라서 본 연구에서는 그림 2와 같이 Ti 결합 화합물에서의 Ti Auger Peak의 특성 에너지 값과 Peak Shape를 관찰하여, AES를 이용하여 Ti 계열의 화합물에 대한 Chemical state 분석의 가능성을 평가하였다.

  • PDF

The Development and Diffusion of Bioenergy Technologies in the Systems Perspective (혁신 시스템 관점에서의 바이오에너지기술 개발과 확산)

  • Jung, Mi-Ae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.137.2-137.2
    • /
    • 2011
  • 본 연구는 바이오에너지 분야의 성장을 혁신 시스템 관점에서 이해할 필요성을 논하고, 시스템 관점에서의 이론적 분석 틀을 제공하고자 한다. 신재생에너지 보급에 의한 지역 및 국가 에너지 시스템 전환을 기술 혁신의 과정으로 이해할 때 혁신 시스템 관점은 기술 개발로부터 선별 및 확산에 이르기까지 관계되는 다양한 주체와 이들 간의 네트워크, 제도 관계를 통합적으로 바라보도록 한다. 특히 혁신 시스템에 대한 동학적 접근은 시스템의 변화에 초점을 맞추어 변화의 동인을 파악하는데 '시스템 기능'이라는 개념을 사용하면 복잡한 바이오에너지 성장 과정에 대한 시기별 접근과 기술 사례별 비교 분석이 용이해진다. 본 연구는 혁신 시스템 관점과 관련된 다양한 개념 정리 및 바이오에너지 분야의 성장에 대한 기존 시스템 관점의 연구들을 검토하여 바이오에너지분야의 성공 및 실패 요인을 도출하고 우리나라 바이오에너지 분야에 적합한 시스템 분석틀을 제시한다.

  • PDF

Characteristics of Acoustic Emission by Expansive Cement Induced Rock Fractures (팽창성 시멘트에 의한 암석균열시의 AE 특성)

  • 김교원
    • The Journal of Engineering Geology
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 1998
  • A study was conducted to determine the characteristics of acoustic emission(AE) events generated by the expansive cement induced rock fracturing. The dominant frequency and the maximum amplitude of the AE events are changed in relation to the rate of expansive pressure development in the hole. The dominant frequencies are in the range of 150∼230kHz for the small hole tests and 400∼500kHz for the large hole test. The maximum amplitudes are in the range of 0.015∼0.050cm/sec and 0.025∼0.064cm/sec, respectively. The fact that AE events of higher amplitude with higher frequency on the large hole test and lower amplitude with lower frequency on the small hole tests were detected, may strongly imply that the amount of energy consumed for a macro-crack in both tests may be similar. The expansive cement induced crack propagates stably without any distinguished event having higher amplitude and this implies that a macro-crack is a result of stable growth of micro cracks.

  • PDF