• Title/Summary/Keyword: ADU

Search Result 63, Processing Time 0.023 seconds

Electrochemical Decontamination of Metallic Wastes Contaminated with Uranium Compounds in a Neutral Salt Electrolyte

  • Park, W. K.;Y. M. Yang;C. H. Jung;H. J. Won;W. Z. Oh;Park, J. H.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.689-695
    • /
    • 2003
  • Electrochemical decontamination process has been applied for recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds such as $UO_2$, ammonium uranyl carbonate (AUC), ammonium di-uranate (ADU), and uranyl nitrate(UN) with tributylphosphate(TBP) and dodecane, which are generated by dismantling the contaminated system components and equipment of a retired uranium conversion plant in Korea Atomic Energy Research Institute (KAERI). Electrochemical decontamination for metallic wastes contaminated with uranium compounds was evaluated through the experiments on the electrolytic dissolution of stainless steel as the material of the system components in neutral salt electrolytes. The effects of type of neutral salt as the electrolyte, current density, and concentration of electrolyte on the dissolution of the materials were evaluated. Decontamination performance tests using the specimens taken from a uranium conversion plant were quite successful with the application electrochemical decontamination conditions obtained through the basic studies on the electrolytic dissolution of structural material of the system components.

  • PDF

Comparison of Correction Coefficients for the Non-uniformity of Pixel Response in Satellite Camera Electronics (위성카메라 전자부의 화소간 응답불균일성 보정계수의 비교검토)

  • Kong, Jong-Pil;Lee, Song-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.89-98
    • /
    • 2011
  • Four kinds of gain and offset correction coefficients that are used to correct the nonuniformity between pixels are discussed. And their correction performance has been compared by performing image correction. using the correction coefficients calculated, on the real image data obtained from a newly fabricated camera electronics system. The performance of the correction coefficients depends in general on the number of the light input levels used to obtain the reference image. The result shows that, as expected obviously, when only two light input levles are used to obtain the reference image, even though its correction coefficients are relatively easily calculated, the correction performance is relatively poor. And with the number of light inputs increased to a value of larger than two, the correction performance is improved. It is noted, however, no Significant performance difference is found between the different correction coefficients employed.

Strategy and Implementation of Land Management Information Systems (토지관리정보체계 개발전략과 구현사례)

  • 최병남;김대종;홍성학
    • Spatial Information Research
    • /
    • v.10 no.1
    • /
    • pp.165-183
    • /
    • 2002
  • The master plan for the land management information system development was established in 1997 and demonstration projects were carried out in Nam-gu, Daegu Metropolis in 1998. As of the end of 2001, 12 project areas have completed installing the land management information system and are now utilizing it in operations or in trial operation and 88 areas are still under construction. Sixteen metropolises and provinces and 232 cities, counties and districts plan to complete the development of land management information system by 2004 and additionally Install a land information center to manage and maintain the land management information system. The land management information system was introduced as one of information technologies to solve the problems arising in the operations of land management and administration. It inevitably accompanies a radical change of working environment, from analogue to digital. It is obviously not a simple job and largely depends on how to entice the officials working in analogue settings into a digitalized world. Therefore, it is not too much to say that the success of the land management information system development project depends on how to rationally adapt the analogue land administrations to a digital environment.

  • PDF

Comparison of Lines from Anther and Maternally-derived dihaploids, Single-seed Descent and Bulk Breeding Method in Flue-cured Tobacco (Nicotiana tabacum L.) (연초(Nicotiana tabacum L.)의 반수체 육종법 1주1계통법, 집단육종에 의한 육성계통의 특성비교)

  • 정윤화;이승철;김달웅
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.14 no.2
    • /
    • pp.104-115
    • /
    • 1992
  • The present study was conducted to compare the relative efficiency of four different breeding methods in tobacco varietal development. A single Fl hybrid plant from cross of two flue-cured cultivars of Nicotiana tabacum L Bright Yellow 4(BY4) and NC95, was selfed. F2population above cross was screened for resistance against bacterial wilt caused by Pseudommonas solanacearum E.F.Smith under the naturally infested field conditions, and the 30 lines were developed from F2 individual plant by anther culture (ADH), maternal method utilizing Nicotiana afpicana (MDH), single- seed descent(SSD) and Bulk breeding method, respectively. All characters except content of total alkaloids of ADH and MDH which wore bred by haploid methods reduced more than that of lines bred by conventional methods(SSD & Bulk) : however, the yields were 8% lower than other lines. The total alkaloid content of ADH was higher than that of MDH, and yield was reduced about 4n even though the number of leaf was identical with the MDH. All other characters of ADH were also reduced significantly. In the lines bred by conventional methods, population developed by SSD showed significantly wider leaf width, shorter plant height, later days to flower, and lower in percent reducing sugar than those by Bulk. The populations derived from haploid method showed greater phenotypic variance and wider range of variation than conventionally developed ones. The results obtained indicate that selection will provide a significantly greater genetic gain for leaf number and leaf length in the ADU and MDH populations, and for plant height and days to flower in the SSD and Bulk populations.

  • PDF

Strengthening Human Immunodeficiency Virus and Tuberculosis Prevention Capacity among South African Healthcare Workers: A Mixed Methods Study of a Collaborative Occupational Health Program

  • Liautaud, Alexandre;Adu, Prince A.;Yassi, Annalee;Zungu, Muzimkhulu;Spiegel, Jerry M.;Rawat, Angeli;Bryce, Elizabeth A.;Engelbrecht, Michelle C.
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.172-179
    • /
    • 2018
  • Background: Insufficient training in infection control and occupational health among healthcare workers (HCWs) in countries with high human immunodeficiency virus (HIV) and tuberculosis (TB) burdens requires attention. We examined the effectiveness of a 1-year Certificate Program in Occupational Health and Infection Control conducted in Free State Province, South Africa in an international partnership to empower HCWs to become change agents to promote workplace-based HIV and TB prevention. Methods: Questionnaires assessing reactions to the program and Knowledge, Attitudes, Skills, and Practices were collected pre-, mid-, and postprogram. Individual interviews, group project evaluations, and participant observation were also conducted. Quantitative data were analyzed using Wilcoxon signed-rank test. Qualitative data were thematically coded and analyzed using the Kirkpatrick framework. Results: Participants recruited (n = 32) were mostly female (81%) and nurses (56%). Pre-to-post-program mean scores improved in knowledge (+12%, p = 0.002) and skills/practices (+14%, p = 0.002). Preprogram attitude scores were high but did not change. Participants felt empowered and demonstrated attitudinal improvements regarding HIV, TB, infection control, and occupational health. Successful projects were indeed implemented. However, participants encountered considerable difficulties in trying to sustain improvement, due largely to lack of pre-existing knowledge and experience, combined with inadequate staffing and insufficient management support. Conclusion: Training is essential to strengthen HCWs' occupational health and infection control knowledge, attitudes, skills, and practices, and workplace-based training programs such as this can yield impressive results. However, the considerable mentorship resources required for such programs and the substantial infrastructural supports needed for implementation and sustainability of improvements in settings without pre-existing experience in such endeavors should not be underestimated.

A Study of Mercury-Cathode Membrane Cells for the Electrolytic Reduction of Uranyl Solutions (膈膜電解槽와 水銀陰極에 依한 Uranyl 溶液의 電解還元)

  • Kim, Jae-Won;Simard, R.
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 1962
  • Bench-scale horizontal cation-permeable membrane cells were constructed to study the effect of cell dimensions on the efficiency of electrolytic reduction of uranyl sulphate solutions flowing continuously over a mercury cathode. Current efficiencies were determined for various cells having length-to-width ratios of 10/1 to 40/1, and for catholyte solutions containing from 20 to 100g $U_3O_8/l$ in sulphuric acid. Optimum current density and solution flowrate were determined under these conditions. The effects of the nitrate and chloride ions were briefly examined.

  • PDF

CTIO 4m SDSS $u$와 CTIO 1m B filter의 투과함수 특성 및 CTIO 1m Y4KCam의 crosstalk

  • Heo, Hyeon-O;Im, Beom-Du;Seong, Hwan-Gyeong;Bessel, Michael S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.155.2-155.2
    • /
    • 2012
  • CTIO 4m 및 CTIO 1m 망원경으로 Westerlund 2의 UBVI 관측을 수행하여, CTIO 4m SDSS $u$ filter의 적색광누출 현상을 발견하였고 그 영향을 분석하였다. 적색광누출 현상은 filter의 투과함수가 설계와는 달리 장파장 영역에서 투과 존재하는 현상으로, CTIO 4m SDSS $u$ filter의 경우 B-V>1.4, V-I>2.0에서 그 영향이 나타나기 시작한다. SDSS $u$ filter의 적색광누출 현상은 별의 고유색지수와 상관없이 관측된 색지수가 클수록 영향이 크며, $B-V{\leq}1.8$, $V-I{\leq}2.8$의 범위에서는 보정이 가능하다. CTIO 1m B filter에서는 성간소광을 받지 않은 별과 성간소광을 많이 받은 별의 표준계변환 결과, $B_{CTIO1m}=B_{Standard}-0.055{\times}E(V-V)$에 해당하는 차이를 보였다. 이러한 차이는 CTIO 1m B filter의 투과함수의 단파장 쪽 날개부분이 표준 Johnson B filter에 비하여 단파장 쪽으로 많이 치우쳐있기 때문으로 보인다. 특히 Ballmer jump에 해당하는 파장인 370 nm에서 filter의 최대투과율에 비하여 32.2%에 달하는 투과율을 보이는데, 이는 Bessell B filter의 3.1%에 비하여 매우 큰 값이다. CTIO 1m 망원경의 Y4KCam CCD에서는 포화된 화소에 의한 crosstalk 뿐 아니라 포화되지 않은 화소에 의한 crosstalk 현상도 보였다. 짧은 노출을 준 영상에서는 5000 ADU 이상에서는 육안에 의한 crosstalk 확인이 가능하며, 포화되지 않은 밝은 별에 의한 crosstalk을 확인하지 않고 측광할 경우 백색왜성으로 오인할 가능성이 있으므로 측광 과정에서 좌표를 통하여 확인할 필요가 있다.

  • PDF

Effect of $UO_2$ Powder Property and Oxygen Potential on Sintering Characteristics of $UO_2-Gd_2O_3$ Fuel

  • Song, Kun-Woo;Kim, Keon-Sik;Yoo, Ho-Sik;Jung, Youn-Ho
    • Nuclear Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.128-139
    • /
    • 1998
  • The effect of UO$_2$ powder property and oxygen potential on characteristics of sintered UO$_2$-Gd$_2$O$_3$ fuel pellets has been investigated. Two types of powder, mixture of AUC-UO$_2$ and Gd$_2$O$_3$powders (type I) and mixture of ADU-UO$_2$ and Gd$_2$O$_3$powders (type II), have been prepared, pressed, and sintered at 168$0^{\circ}C$ for 4 hours. Four sintering atmospheres with different mixing ratios of $CO_2$to H$_2$ gas ranging from 0 to 0.3 have been used. UO$_2$-Gd$_2$O$_3$ fuel has lower sintered density than UO$_2$ fuel, and the density drop is larger for powder type I than for powder type II. As the oxygen potential increases, the sintered density of UO$_2$-2wt% Gd$_2$O$_3$pellets increases but that of UO$_2$-10wt% Gd$_2$O$_3$ pellets decreases. It is found that pores are newly formed in UO$_2$-10wt% Gd$_2$O$_3$ pellets in accordance with the decrease in density. The grain size of UO$_2$-Gd$_2$O$_3$ fuel increases and a short range G4 distribution becomes homogeneous as the oxygen potential increases. A long range ed distribution and grain structure are inhomogeneous for powder type II. The lattice parameter of (U,Gd)O$_2$solid solution decreases linearly with Gd$_2$O$_3$ content. The dependence of UO$_2$-Gd$_2$O$_3$fuel characteristics on powder type and sintering atmosphere have been discussed.

  • PDF

Effects of Powder Property and Sintering Atmosphere on the Properties of Burnable Absorber Fuel : I. $UO_2-Gd_2O_3$ Fuel

  • K. W. Song;Kim, K. S.;H. S. Yoo;Kim, J. H.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.171-176
    • /
    • 1997
  • UO$_2$-Gd$_2$O$_3$fuel has been sintered to study the effect of powder property and sintering atmospheres on densification and microstructure. Three types of powders have been used; AUC-UO$_2$ powder and ADU-UO$_2$ powder were mixed with Gd$_2$O$_3$ Powder, and co-milled AUC-UO$_2$ and Gd$_2$O$_3$ powder. UO$_2$-(2, 5, 10)wt% Gd$_2$O$_3$pellets have been sintered at 168$0^{\circ}C$ for 4 hours in the mixture of H$_2$ and $CO_2$ gases, of which oxygen potential has been controlled by the ratio of $CO_2$ to H$_2$ gas. Densities of UO$_2$-Gd$_2$O$_3$ fuel pellets are quite dependent on powder types, and UO$_2$-Gd$_2$O$_3$ fuel using co-milled UO$_2$ powder yields the highest density. A long range homogeneity of Gd is determined by powder mixing. As the oxygen potential of sintered atmosphere increases, the sintered densities of UO$_2$-Gd$_2$O$_3$ pellets decrease but grain size increases. In addition, (U, Gd)O$_2$ solid solution becomes more homogeneous. The UO$_2$-Gd$_2$O$_3$fuel having adequate density and homogeneous microstructure can be fabricated by co-milling powder and by high oxygen potential.

  • PDF

Electrochemical Decontamination of Metallic Wastes Contaminated with Uranium Compounds (우라늄화합물로 오염된 금속폐기물의 전해제염)

  • 양영미;최왕규;오원진;유승곤
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • A study on the electrolytic dissolution of SUS-304 and Inconel-600 specimen was carried out in neutral salt electrolyte to evaluate the applicability of electrochemical decontamination process for recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant in Korea. Although the best electrolytic dissolution performance for the specimens was observed in a Na2s04 electrolyte, a NaNO$_3$ neutral salt electrolyte, in which about 30% for SUS-304 and the same for Inconel-600 in the weight loss was shown in comparison with that in a Na$_2$SO$_4$ solution, was selected as an electrolyte for the electrochemical decontamination of metallic wastes with the consideration on the surface of system components contacted with nitric acid and the compatibility with lagoon wastes generated during the facility operation. The effects of current density, electrolytic dissolution time, and concentration of NaNO$_3$ on the electrolytic dissolution of the specimens were investigated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as UO$_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion facility were performed in 1M NaNO$_3$ solution with the current density or In mA/$\textrm{cm}^2$. it was verified that the electrochemical decontamination of the metallic wastes contaminated uranium compounds was quite successful in a NaNO$_3$ neutral salt electrolyte by reducing $\alpha$ and $\beta$ radioactivities below the level of self disposal within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF