• Title/Summary/Keyword: ACI 318-05

Search Result 39, Processing Time 0.024 seconds

Ultimate Strength Analysis of Slab-Column Joints Subjected to Lateral Loads Using 3-Dimensional Grid Strut-Tie Model Approach (3차원 격자 스트럿-타이 모델 방법을 이용한 횡하중을 받는 슬래브-기둥 접합부의 극한강도 평가)

  • Son, Woo-Hyun;Yun, Young-Mook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.265-268
    • /
    • 2008
  • Slab-column joints have been used in the constructions of many structures and buildings. However, as the prediction of the failure behavior and ultimate strength of the joints subjected to lateral loadings is very difficult, the current building and structural design codes do not explain the failure behavior of the joints clearly. In this study, the applicability of the 3-dimensional grid strut-tie model approach, suggested for analysis and design of 3-dimensional structural concrete with disturbed regions, to the ultimate analysis and design of the joints is examined by evaluating the failure strengths of 43 slab-column joints tested to failure. The validity of the 3-dimensional grid strut-tie model approach is also verified by comparing the strength evaluation results with those by ACI 318-05 and FIB 1999.

  • PDF

Load Distribution Ratios of Indeterminate Strut-Tie Models for Simply Supported RC Deep Beams - (II) Validity Evaluation (단순지지 RC 깊은 보 부정정 스트럿-타이 모델의 하중분배율 - (II) 적합성 평가)

  • Kim, Byung Hun;Jeung, Chan Haek;Yun, Young Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.269-279
    • /
    • 2008
  • In this study, the ultimate strengths of 229 simply supported reinforced concrete deep beams tested to shear failure were evaluated by the ACI 318-05's strut-tie model approach implemented with the presented indeterminate strut-tie model and its load distribution ratio. The ultimate strengths of the deep beams were also estimated by the experimental shear equations, design codes that were based on experimental and theoretical shear strength models, and current strut-tie model design codes. The validity of the present strut-tie model and its load distribution ratio was examined through the comparison of the strength analysis results classified according to the prime design variables of the shear span-to-effective depth ratio, flexural reinforcement ratio, and compressive strength of concrete.

Shear Capacity of Reinforced Concrete Continuous T-Beams Externally Strengthened with Wire Rope Units (와이어로프로 외부 보강된 철근콘크리트 연속 T형 보의 전단내력)

  • Yang, Keun-Hyeok;Sim, Jae-Il;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.773-783
    • /
    • 2007
  • A simple unbonded-type shear strengthening technique for reinforced concrete beams using wire rope units is developed. Six two-span continuous T-beams externally strengthened with wire rope units and an unstrengthened control beam were tested. The main variables investigated were the amount and prestressing force of wire rope units. All specimens had the same geometrical dimension and arrangement of internal reinforcement. Influence of the distribution of vertical stresses in beam web owing to the prestressing force of wire rope units on the diagonal shear cracking load and the ultimate shear capacity of beams tested is presented. Based on the current study, it can be concluded that the amount and initial prestress of wire rope should be limited to be above 2.5 times the minimum shear reinforcement ratio specified in ACI 318-05 and below 0.6 times its own tensile strength, respectively, to ensure the enhancement of shear capacity and ductile failure mode of the strengthened beams. A numerical analysis based on the upper-bound theorem is developed to assess the shear capacity of continuous T-beams strengthened with wire rope units. From the comparisons of measured and predicted shear capacities, a better agreement is achieved in the proposed numerical analysis than in empirical equations recommended by ACI 318-05.

Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems (포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동)

  • Han, Sang-Whan;Kee, Seong-Hoon;Kang, Tomas H.K.;Cho, Jong;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.595-602
    • /
    • 2006
  • An experimental study was conducted to investigate seismic behaviour of post-tensioned(PT) exterior slab-column connections used for the purpose to resist gravity loads only. For these, 2/3-scale, two PT post-tensioned exterior connections with two different tendon arrangement patterns and one conventional reinforced concrete(RC) exterior connection was tested under quasi-static, uni-directional reversed cyclic loading. During the lateral testing, gravity forces transferred to the column were kept constant to closely simulate a moment to shear ratio of a real building. One of the objectives of this study was to assess the necessity and/or the quantity of bottom bonded reinforcement needed to resist moment reversal which would occur under significant inelastic deformations of the adjacent lateral force resisting systems. The ACI 318 and 352 provisions for structural integrity were applied to provide the bottom reinforcement passing through the column for the specimens. Prior test results were also collected to conduct comparative studies for some design parameters such as the tendon arrangement pattern, the effect of post-tensioning forces and the use of bottom bonded reinforcement. Consequently, the impact of tendon arrangement on the seismic performance of the PT connection, that is lateral drift capacity and ductility, dissipated energy and failure mechanism, was considerable. Moreover, test results showed that the amount of bottom reinforcement specified by ACI 352. 1R-89 was sufficient for resisting positive moments arising from moment reversal under reversed cyclic loads. Shear strength of the tested specimens was more accurately predicted by the shear strength equation(ACI 318) considering the average compressive stress over the concrete($f_{pc}$) due to post-tensioning forces than that without considering $f_{pc}$.

Long-term Deflection of R/C Beam with Variable Substitution Ratio of Recycled Aggregate (순환골재 치환율에 따른 R/C보의 장기처짐에 관한 연구)

  • Yoon, Seung-Joe;Seo, Soo-Yeon;Lee, Woo- Jin;Kang, Seong-Duk;Kim, Dae-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.37-40
    • /
    • 2006
  • In this paper, long term deflection of RC beam with variable substitution ratio of recycled aggregate is investigated. 6 RC beam specimens are designed using concrete made of coarse aggregate of 25mm size, mix strength of 21MPa, slump of 12cm and air content of $5.0{\pm}1.5%$. A few concrete blocks are made and used for long term loading. The loading and deflection instrumentation are conducted following the process codified in ACI 318-05 code. Test result shows that the deflection of specimens depends on the compressive strength of concrete. And it is concluded that the deflection of RC beam can be predicted like normal beam using ACI formula if certain level of compressive strength is acquired even recycled aggregate is used in making the beam.

  • PDF

Experimental study on lateral behavior of precast wide beam-column joints

  • Kim, Jae Hyun;Jang, Beom Soo;Choi, Seung-Ho;Lee, Yoon Jung;Jeong, Ho Seong;Kim, Kang Su
    • Earthquakes and Structures
    • /
    • v.21 no.6
    • /
    • pp.653-667
    • /
    • 2021
  • In this study, cyclic loading tests were conducted on the precast concrete (PC) wide beam (WB)-column joints. Two beam-column joint specimens were fabricated with the arrangement and anchorage details of the reinforcing bars penetrating the beam and column as variables. Through a cyclic loading test, the lateral load-story drift ratio responses, seismic performance characteristics (e.g., ductility, overstrength factor), energy dissipation, strength and stiffness degradations of each specimen were compared and analyzed based on the various indices and the current structural codes (ACI 318-19 and ACI 374.1-05 report). In addition, the shear lag effect was confirmed through the gauge values of the PC beam, and the differences in seismic performance between the specimens were identified on that basis.

Seismic Behavior of High-Strength Reinforced Concrete Bridge Columns (고강도 철근콘크리트 교각의 내진 거동)

  • Hwang Sun-Kyoung;Lee Chin-Ok;Ryu Hyo-Jin;Yun Hyun-Do;Lim Byung-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.505-511
    • /
    • 2005
  • This experimental investigation was conducted to examine the seismic performance of reinforced concrete bridge columns. The columns were subjected to a constant axial load and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research were the volumetric ratios of transverse reinforcement (ps=0.96, 1.44 percent) and axial load ratios (P/Po=0.05, 0.1, 0.2) and concrete strengths (35, 60MPa). Test results showed that bridge columns with $44\%$ higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behavior. For bridge columns with axial load ratio(P/Po) less than 0.2, the ratio of $M_{max}\;over\;M_{ACI}$, nominal moment capacity predicted by ACI 318-02 provisions, was consistently greater than 1 with approximately a $20\%$ margin of safety.

Predicting Actual Strength of Shear Reinforcement Using Effective Stirrup Concept (유효 스터럽 개념을 이용한 전단보강근의 강도 예측)

  • Kwon, Ki-Yeon;Yang, Jun-Mo;Lee, Joo-Ha;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.99-107
    • /
    • 2008
  • This paper presents the prediction of the actual strength of shear reinforcement on the basis of the concept of effective stirrups. The prediction method incorporating the shear cracking angle was proposed with the estimation by the Modified Compression Field Theory (MCFT). To check the validity of the method, discussion of the current ACI 318-05 and comparison of 39 test results from the literature including author's retrospective test data were made. The influencing factors of compressive concrete strength and type of shear-reinforcement were also investigated. Furthermore, two full-scale beam specimens shear-reinforced with headed bars were tested to demonstrate the applicability of the proposed method.

Calibration of Load and Resistance Factors in KCI Code Based on Domestic Data (국내 통계자료를 이용한 설계기준의 하중저항계수 검증)

  • Kim, Jee-Sang;Kim, Jong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.495-501
    • /
    • 2011
  • The load combinations in current KCI Design Code are determined with reference to those in ACI 318-05, which adopts the LRFD (load and resistance factor design) format. The load and resistance factors in LRFD format should be determined to meet the required levels of reliability index or probability of failure for various predetermined failure modes, which are also based on the statistical data reflecting locality and contemporary situation. However, the current KCI Design Code has been written utilizing foreign data, because of insufficiency in accrued data in Korea. This study considered the current safety levels of KCI Code based on published domestic data to evaluate appropriateness of the current KCI regulations. Based on the calibrated reliability index of the existing Code, the new resistance factors are suggested. The results presented in this paper can be considered as a basic research for establishment of unique design format for future Korean Codes.

Mechanical Properties of Hwangtoh-Based Alkali-Activated Concrete

  • Yang, Keun-Hyeok;Hwang, Hey-Zoo;Lee, Seol
    • Architectural research
    • /
    • v.11 no.1
    • /
    • pp.25-33
    • /
    • 2009
  • This study presents the testing of 15 hwangtoh-based cementless concrete mixes to explore the significance and limitations of the development of eco-friendly concrete without carbon dioxide emissions while maintaining various beneficial effects. Hwangtoh, which is a kind of kaolin, was incorporated with inorganic materials, such as calcium hydroxide, to produce a cement-less binder. The main variables investigated were the water-to-binder ratio and fine aggregate-to-total aggregate ratio to ascertain the reliable mixing design of hwangtoh-based cementless concrete. The variation of slump with elapsed time was recorded in fresh concrete specimens. Mechanical properties of hardened concrete were also measured: including compressive strength gain, splitting tensile strength, moduli of rupture and elasticity, stress-strain relationship, and bond resistance. In addition, mechanical properties of hwangtoh-based cement-less concrete were compared with those of ordinary portland cement (OPC) concrete and predictions obtained from the design equations specified in ACI 318-05 and CEB-FIP for OPC concrete, wherever possible. Test results show that the mechanical properties of hwangtoh-based concrete were significantly influenced by the water-to-binder ratio and to less extend by fine aggregate-to-total aggregate ratio. The moduli of rupture and elasticity of hwangtoh-based concrete were generally lower than those of OPC concrete. In addition, the stress-strain and bond stress-slip relationships measured from hwangtoh-based concrete showed little agreement with the design model specified in CEB-FIP. However, the measured moduli of rupture and elasticity, and bond strength were higher than those given in ACI 318-05 and CEB-FIP. Overall, the test results suggest that the hwangtoh-based concrete shows highly effective performance and great potential as an environmental-friendly building material.