• 제목/요약/키워드: ACH, Air Change per Hour

검색결과 19건 처리시간 0.026초

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

잠금장치 작동에 따른 미서기 및 LS 창호 시스템의 기밀성 (Effect of Lock Operations on Airtightness of Sliding and LS Window Systems)

  • 박종준;윤유라;김영일;정광섭
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.449-454
    • /
    • 2015
  • In this study, the effects of lock operations on the infiltration rates for the two window types sliding and lift sliding (LS) are investigated through experiment and simulation. The airtightness levels of the two window types-with locks both on and off-were measured according to the KS F 2292 Test method of airtightness that is used for windows and doors. The air-flow rates of both window types with the locks on for a pressure differential of 10 Pa are $1.98m^3/(m^2h)$ and $1.68m^3/(m^2h)$, respectively; with the locks off, the air-flow rates of the sliding and LS windows are $2.64m^3/(m^2h)$ and $5.83m^3/(m^2h)$, respectively, whereby the air-flow rates are 33% higher for sliding and 247% higher for LS. The air change per hour (ACH) was calculated using the ventilation-simulation software CONTAM. For the sliding window, the ACH changed from 0.45 to 0.57 when the lock was operated from on to off, representing an increase of 27%. For the LS window, the ACH changed from 0.29 to 0.81, showing an increase of 179%.

환기방식별 실내 환기효율 분석에 관한 실험적 연구 (An Experimental Analysis of Ventilation Effectiveness using Tracer Gas)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.260-266
    • /
    • 2006
  • A tracer gas technique based on ASTM Standard E741-83 was used to measure ventilation performances in a model chamber ($0.84m{\times}0.68m{\times}0.7m$) with an exhaust fan and a supply fan. Experiments were performed for the ventilation effectiveness on three types of mechanical ventilation systems. For all cases. higher ventilation effectiveness was found in the type to ventilation system due to shorter residual time of air compared to type 1 and type 3.

실내사무환경에서의 환경성담배연기(ETS)중 일부 휘발성유기화합물(VOC)에 관한 연구 (A Study on Volatile Organic Compounds(VOC) in Environmental Tobacco Smoke(ETS) at Indoor Office Environments)

  • 하권철
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.87-98
    • /
    • 2001
  • There has been increased interest in the health effects of the Environmental Tobacco Smoke(ETS) as a confirmed human carcinogen. It has been known to be extremely difficult to make an accurate assessment of exposure to ETS since it is consisted of a variety of components and there are a number of labile chemicals. Therefore, it is necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment to ETS in the field of environmental health. The purpose of this research is to evaluate the concentration of ETS using VOC in indoor office environments. The correlations and concentrations of benzene, RSP, 3-EP, nicotine that are indicators for ETS were investigate with smoking density, air change per hour(ventilation rate). Air samples were taken in smoking room(7 sites), smoking allowed office (3 sites), corridor outside smoking room(7 sites), non-smoking office (9 sites). The concentrations of benzene showed significant difference according to category of indoor office environments. The geometric mean concentration of benzene were 23.56 ${\mu}{\textrm}{m}$/㎥(range 4.80~192.90 ${\mu}{\textrm}{m}$/㎥) in smoking rooms. 6.16 ${\mu}{\textrm}{m}$/㎥ in smoking allowed offices, 1.32 ${\mu}{\textrm}{m}$/㎥ in the non-smoking offices respectively. The ratios of the concentration of benzene between outdoor air and smoking room, smoking allowed office, and non-smoking indicators concentrations, SD, and SI were 0.82(benzene and nicotine). 0.76(benzene and RSP), 0.60(benzene and SD), 0.76(benzene and SI). It is proposed that benzene is a good indicator for ETS.

  • PDF

실내사무환경에서의 환경성담배연기(ETS) 중 지표물질에 관한 연구

  • 하권철;백남원;박동욱;윤충식
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 가을학술대회
    • /
    • pp.154-159
    • /
    • 2005
  • The markers for Environmental Tobacco Smoke(ETS) a.e necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment. The purpose of this research is to evaluate Indoor environment using the concentration of ETS and the correlations between markers(RSP, nicotine, 3-EP) and environmental conditions(smoking density, ventilation rate). The mean ACH(air change per hour) in smoking rooms showed non-compliance with ASHRAE standard value. The concentrations of RSP, 3-EP, nicotine showed log-normal distributions, and became different statistically depending on smoking condition(p<0.01). The geometric mean concentration of RSP in smoking room was 441.7 ${\mu}g/m^3$ that is far exceeded environmental standard(150 ${\mu}g/m^3$). The correlation coefficients between RSP and SI, 3-EP and SI, and Nicotine and SI were 0.67, 0.84, 0.74 respectively. The correlation coefficient between nicotine and 3-EP, Nicotine and RSP, and RSP and 3-EP were 0.76, 0.78, 0.57 respectively.

  • PDF

밀폐공간에서 수소 누설로 인한 수소 제트 확산에 대한 수치해석 (THE NUMERICAL SIMULATION OF HYDROGEN JET DIFFUSION FOR HYDROGEN LEAKAGE IN THE ENCLOSED GEOMETRY)

  • 안혁진;이상혁;허남건;이문규;용기중
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.176-182
    • /
    • 2009
  • In the present study, a numerical simulation for the diffusion of hydrogen jet in a enclosure was performed to aid the leakage test of the hydrogen for the safety of the hydrogen vehicle. The temporal and spatial distributions of the hydrogen concentration in the test chamber are predicted from the present numerical analyses. Flammable region of 4-74% and explosive region of 18-59% hydrogen by volume was identified from the present results. Factors influencing the diffusion of the hydrogen jet were examined to evaluate the effectiveness of forced ventilation for relieving the accumulation of the leaked hydrogen gas in the chamber, which include location of open windows, size of leakage nozzle, and leakage rate among others. The distribution of the concentration of the leaked hydrogen for various cases can be used as a database in various applications for the hydrogen safety.

  • PDF

밀폐공간에서 수소 누설로 인한 수소 제트 확산에 대한 수치해석 (THE NUMERICAL SIMULATION OF HYDROGEN JET DIFFUSION FOR HYDROGEN LEAKAGE IN THE ENCLOSED GEOMETRY)

  • 안혁진;이상혁;허남건;이문규;용기중
    • 한국전산유체공학회지
    • /
    • 제14권2호
    • /
    • pp.32-38
    • /
    • 2009
  • In the present study, a numerical simulation for the diffusion of hydrogen jet in a enclosure was performed to aid the leakage test of the hydrogen for the safety of the hydrogen vehicle. The temporal and spatial distributions of the hydrogen concentration in the test chamber are predicted from the present numerical analyses. Flammable region of 4-74% and explosive region of 18-59% hydrogen by volume was identified from the present results. Factors influencing the diffusion of the hydrogen jet were examined to evaluate the effectiveness of forced ventilation for relieving the accumulation of the leaked hydrogen gas in the chamber, which include location of open windows, size of leakage nozzle, and leakage rate among others. The distribution of the concentration of the leaked hydrogen for various cases can be used as a database in various applications for the hydrogen safety.

동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석 (Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell)

  • 강은철;박용대;이의준;윤태권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가 (Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests)

  • 곽병창;이수만;김길태;김종엽
    • 토지주택연구
    • /
    • 제13권3호
    • /
    • pp.93-106
    • /
    • 2022
  • 일반적으로 실내 공기질을 조절하기 위해서는 환기의 역할이 중요하다. 최근 코로나-19 등 감염병의 확산으로 거주자들의 실내에서 보내는 시간이 늘어남에 따라 환기의 중요성은 더욱 높아지고 있으며, 환기성능에 대한 관심도 더욱 높아지는 추세이다. 많은 국가에서 현재 환기 성능을 파악하는 지표로서 시간당 환기횟수를 사용하고 있으며, 국내에서도 공동주택을 대상으로 시간당 0.5회 이상의 환기횟수를 확보하도록 규제하고 있다. 하지만, 선행연구 및 국내외 환기성능 평가 관련 표준을 검토한 결과 시간당 환기횟수만을 통해 실내 환기 성능을 평가하는데에는 실질적 실내 환기 성능을 평가하는 데에는 한계가 있는 것으로 나타났으며, 실질적인 환기 성능을 평가하기 위해서는 실내 국소부위를 대상으로 오염물질 저감속도와 공간내 환기 성능 균일도 등을 고려하는 것이 필요할 것이다. 이에 대해 본 연구에서는 추적가스 희석법을 이용한 실증 실험을 통해 측정 위치별 유속, 공기연령 및 환기효율을 측정하고 비교하였으며, 측정점별 조합에 따른 평균값과 공간 내 중심점에서의 측정값을 비교하여 측정점 선정에 따른 환기성능 차이를 비교 조사하였다. 본 연구 결과는 향후 실환경 기반의 주거공간 실내 환기성능을 평가하기 위한 실험절차 개발을 위한 기초자료로 활용될 수 있을 것이다.