• 제목/요약/키워드: AC-CT

검색결과 87건 처리시간 0.035초

CT와 $^{68}Ge$ 감쇠보정 $^{18}F-FDG$ PET 영상의 정량적 비교: 측정감쇠보정대 분할감쇠보정 (Quantitative Comparisons between CT and $^{68}Ge$ Transmission Attenuation Corrected $^{18}F-FDG$ PET Images: Measured Attenuation Correction vs. Segmented Attenuation Correction)

  • 최준영;우상근;최용;최연성;이경한;김병태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권1호
    • /
    • pp.49-53
    • /
    • 2007
  • 목적: CT를 사용한 측정감쇠보정(measured attenuation correction; CT-MAC) PET 영상은 $^{68}Ge$을 사용한 분할감쇠보정(segmented attenuation correction; Ge-SAC) PET 영상보다 섭취값이 높은 것으로 알려져 있다. 이 연구에서는 정상인과 암으로 진단된 또는 암이 의심되는 환자를 대상으로 $^{18}F-FDG$ PET을 시행하고, 감쇠보정방법을 달리하여 각각 4가지 PET 영상을 얻고 이를 서로 정량적으로 비교하였다. 대상 및 방법: 5명의 정상인(남:여=4:1; 평균나이, $29.4{\pm}2.5$세)과 35명의 환자(남17, 여18; 평균나이 $52.7{\pm}15.2$세)를 대상으로 $^{18}F-FDG$ PET을 시행하였다. 먼저, CT 영상(140 KeV, 80 mAs)을 얻은 뒤 방출영상(5 min/bed)과 $^{68}Ge$ 투과영상(3 min/bed)을 차례로 얻었다. Ordered subsets expectation maximization (28 subsets, 2 iterations) 영상재구성법과 CT-MAC, CT-SAC, Ge-MAC, Ge-SAC의 4가지 감쇠보정방법을 사용하여 4가지 PET 영상을 얻었다. 정상인군에서는 대표적인 정상조직의, 환자군에서는 비정상적인 섭취를 보이는 병소의 SUV를 구하고, 이를 서로 비교 하였다. 결과: 정상인 군에서 CT-MAC 사용하여 감쇠보정한 PET 영상의 18개 정상조직의 SUV는 나머지 3가지 종류의 PET 영상에 비하여 모두 유의하게 높았다($3.1%{\sim}4.1%$; p<0.001). 환자군에서는 총 145개 병소의 국소 FDG 섭취증가 병변이 발견되었다. CT-MAC 사용한 PET 영상의 SUV 값은 나머지 3가지 PET 영상에 비하여 모두 유의하게 높았다($2.4%{\sim}5.1%$; p<0.001). Ge-MAC 사용한 PET 영상의 SUV 값은 CT-SAC와 Ge-SAC 사용한 PET 영상에 비하여 유의하게 높았다(p<0.001). 그러나, CT-SAC와 Ge-SAC PET 영상사이의 SUV에는 유의한 차이가 없었다. 폐병변에서는 감쇠보정방법사이에 섭취값이 유의한 차이가 없는 반면, 뼈병변에서는 이러한 차이가 가장 컸다($3.8%{\sim}9.6%$; p<0.01). 결론: $^{18}F-FDG$ PET 영상에서 섭취값은 CT-MAC로 감쇠보정을 했을 때에 가장 높다. CT 감쇠보정 및 MAC 사용, 2가지 모두가 이 차이에 기여했을 것이며, 이 중 MAC 사용이 더 크게 작용한 것으로 보인다. 감쇠보정방법이 다른 PET 영상들사이의 섭취값을 비교할 때는 이러한 차이를 고려해야 할 것이다.

디지털 샘플링 방법을 사용한 교류전압과 전류의 (Traceable AC Voltage and Current Measurements Using Digital Sampling Technique)

  • 위제싱허;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.686_687
    • /
    • 2009
  • The traceability maintenance system for the AC voltage and current has been developed at the frequency range of 20 Hz to 100 Hz without using any compensation technique which is used at thermal converter (TC) ac-dc transfer system at low frequencies. The system uses a digital voltmeter (DVM) as a data acquisition system of the input waveform and stored data in memory. The developed algorithm acquires and processes the sampling data to calculate the root mean square (rms) value of the input voltage of DVM which operates at DC 10 V range for better accuracy. The best uncertainty of the AC voltage measurements is $3 {\mu}V/V$ within the frequency range. The best uncertainty of the AC current measurements is better than the $5 {\mu}A/A$ and mainly depend on the current to voltage converter, ac-dc current shunt or Current Transformer (CT), used for the measurement

  • PDF

Carotid Arterial Calcium Scoring Using Upper Airway Computed Tomography in Patients with Obstructive Sleep Apnea: Efficacy as a Clinical Predictor of Cerebrocardiovascular Disease

  • Jae Hoon Lee;Eun-Ju Kang;Woo Yong Bae;Jong Kuk Kim;Jae Hyung Choi;Chul Hoon Kim;Sang Joon Kim;Kyoo Sang Jo;Moon Sung Kim;Tae Kyung Koh
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.631-640
    • /
    • 2019
  • Objective: To evaluate the value of airway computed tomography (CT) in patients with obstructive sleep apnea (OSA) as a predictor of cerebrocardiovascular disease (CCVD) clinically, by quantitatively analyzing carotid arterial calcification (CarAC). Materials and Methods: This study included 287 patients aged 40-80 years, who had undergone both polysomnography (PSG) and airway CT between March 2011 and October 2015. The carotid arterial calcium score (CarACS) was quantified using the modified Agatston method on each upper airway CT. The OSA severity was categorized as normal, mild, moderate, and severe using the PSG results. Clinical characteristics, comorbid diseases, and lipid profiles of all patients were analyzed, and the prevalence of CCVDs was investigated during the follow up period (52.2 ± 16.0 months). Results: CCVD occurred in 27 patients (9.3%) at the end of follow-up, and the CCVD-present groups showed a significantly older mean age (57.5 years vs. 54.2 years), higher prevalence of hypertension (59% vs. 34%) and CarAC (51.9% vs. 20.8%), whereas sex, other comorbid diseases, and severity of OSA were not significantly different from the CCVD-absent group. A univariate analysis showed that age, hypertension, incidence of CarAC, and CarACS were risk factors for the occurrence of CCVD events. In a multivariate analysis, the incidence of CarAC was the only independent risk factor for CCVD. Conclusion: CarAC is an independent risk factor for CCVD, whereas the severity of OSA is not a contributory risk factor in patients with OSA. Therefore, additional analysis of CarACS based on airway CT scans may be useful for predicting CCVD.

전류변성기 비교기와 정밀션트저항을 이용한 전류변성기용 부담의 평가기술 (Evaluation Technique of Burden for Current Transformer using Current Transformer Comparator and Precise Shunt Resistor)

  • 이상화;강전홍;김명수;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.250-256
    • /
    • 2006
  • Both ratio error and phase angle error in current transformer(CT) depend critically on values of CT burden. Thus, precise measurement of CT burden is very important for the evaluation of CT. A method for the measurement of CT burden has been developed by employing the portable shunt precise resistor with negligible AC-DC resistance difference less than $10^{-5}$. The burden value(value and power factor) can be calculated from resistance and reactance obtained by measuring the change of ratio error and phase angle error caused by the change of shunt resistor. The uncertainty for the method is evaluated and found to be abut 2 %.

소형 AC 발전기의 주파수 모니터링 시스템 설계 및 구현 (Design and Implementation of the frequency Monitoring System for the Small AC Generator)

  • 박지상;전민호;이명의
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.997-999
    • /
    • 2013
  • 본 논문에서는 2대 이상의 소형 발전시스템에서 안정적인 전력공급을 위해 서로 다른 발전기에서 생성되는 전압, 위상, 주파수를 동기화하기 위한 전력 주파수 모니터링시스템을 개발하였다. 전력 라인에 흐르는 전류의 양을 측정하기 위해 CT 센서를 사용하였으며, 전압을 측정하기 위해 PT 센서를 사용하였다. 실험결과 본 논문에서 개발한 전력 주파수 모니터링 시스템을 이용하여 전력 주파수를 측정할 수 있음을 확인하였다. 이를 이용할 경우 2대 이상의 소형 발전기를 이용한 발전 시스템에서 효율적으로 전력을 제어할 수 있을 것이다.

  • PDF

Association Analysis of Common Genetic Variations in MUC5AC Gene with the Risk of Non-cardia Gastric Cancer in a Chinese Population

  • Zhou, Cheng-Jiang;Zhang, Liu-Wei;Gao, Fang;Zhang, Bin;Wang, Ying;Chen, Da-Fang;Jia, Yan-Bin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권10호
    • /
    • pp.4207-4210
    • /
    • 2014
  • Several lines of evidence suggest that genetic variation in MUC5AC gene might contribute to the risk of gastric cancer. We conducted a case-control study to evaluate the relationship between common genetic variations in MUC5AC gene and non-cardia gastric cancer using an LD-based tagSNP approach in Baotou, north-western China. We genotyped 12 tagSNPs by TaqMan method among 288 cases with non-cardia gastric cancer and 281 normal controls. Unconditional logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (CIs) for non-cardia gastric cancer risk in association with alleles, genotypes and haplotypes. We observed that the frequencies of rs3793964 C allele and rs11040869 A allele were significantly lower in cases than in controls. Meanwhile, minor allele homozygotes of rs3793964 and rs11040869 were significantly associated with a decreased risk of non-cardia gastric cancer when compared with their major allele homozygotes. Furthermore, a statistically significantly protective effect of rs885454 genotypes on non-cardia gastric cancer was also observed (for CT vs. CC: OR=0.581, 95%CI=0.408-0.829; for CT/TT vs. CC: OR=0.623, 95%CI=0.451-0.884). Our results indicated that some common genetic variations in the MUC5AC gene might have effects on the risk of non-cardia gastric cancer in our studied population.

AC 부하를 갖는 동기전동기의 고정도 속도제어기법 분석 (Analysis of Speed Ripple Reduction Methods for Permanent Magnet Synchronous Motor with Eccentric-weight Load)

  • 박정우;김종무;이기욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.149-153
    • /
    • 2003
  • AC 부하를 갖는 동기전동기에 있어서, 동기전동기의 속도리플을 저감시키기 위한 문제를 풀기위해 3가지 제어기법에 대해 비교를 한 후 가장 강인한 제어기법에 대해 분석하였다. AC 부하를 갖는 특별한 제어 대상으로 엑스선 전산화 단층촬영 장치(CT)용 겐트리를 선정하였으며 시스템이 갖는 특별한 구조에 의해 이러한 시스템 특성을 갖는다. 동기전동기의 출력 축에 링(Fing) 모양의 원판 프레임을 갖으며, 이 원판 표면에 무게가 서로 다른 여러 장치(X_선 튜브, X-선 검출기, 고압발생장치, DAS 장치, 온도조절장치 등)를 부착하여 영상 획득 시스템의 회전부를 구축하기 때문이다. 이러한 시스템에서는 무게 평형을 갖지 못하는 편심 무게가 존재하게 되며 이로써 전동기 관점에서는 AC 부하처럼 인식되는 제어 조건으로 인식 될 수 있다. AC 부하를 갖는 동기전동기에 대해 일반적인 벡터제어 알고리즘으로 제어를 수행하면 정상상태에서도 속도 오차가 "0" 으로 줄어들지 않고 AC 형태의 오차 성분이 존재하며 편심 무게의 크기에 비례하여 진폭이 커지는 특성을 갖는다. 이러한 문제점을 해결하기 위하여 Sine파 보상전류를 갖는 속도제어기법, 펀심부하토크 관측기를 이용한 속도제어기법, 그리고 기준모델제어기법을 소개하였다. 각 방법에 대한 실험 결과로부터 편심무게의 변동과 편심 위치의 변동 조건에서 기준모델제어기법이 강인한 제어 특성과 리플저감 측면에서 가장 우수함을 검증하였다. 이로써 AC 부하 조건에서 고정도 속도 제어기가 요구되는 경우 좋은 선택의 지침이 될 수 있다고 본다.

  • PDF

Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.

배전용 몰드변압기 적용을 위한 EMNC의 교류절연파괴특성 연구 (AC Insulation Breakdown Properties of the EMNC to Application of Distribution Molded Transformer)

  • 박재준
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.649-656
    • /
    • 2013
  • A conventional epoxy-microsilica composite (EMC) and an epoxy-microsilica-nanosilicate composite (EMNC) were prepared in order to apply them to mold-type transformers, current transformers (CT) and potential transformers (PT). Nanosilicate was exfoliated in a epoxy resin using our electric field dispersion process and AC insulation breakdown strength at $30{\sim}150^{\circ}C$, glass transition temperature and viscoelasticity were studied. AC insulation breakdown strength of EMNC was higher than that of EMC and that value of EMNC was far higher at high temperature. Glass transition temperature and viscoelasticity property of EMNC was higher than those of EMC at high temperature. These results was due to the even dispersion of nanosilicates among the nanosilicas, which could be observed using transmission electron microscopy (TEM). That is, the nanosilicates interrupt the electron transfer and restrict the mobility of the epoxy chains.

PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가 (The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT)

  • 홍건철;박선명;정은경;최춘기;석재동
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.172-176
    • /
    • 2010
  • PET/CT 검사에서 발생하는 환자의 움직임은 감쇠보정의 불일치를 초래하여 정량평가에 영향을 주게 되어 결과의 정확도를 저하시키게 된다. 본 연구에서는 PET/CT 3D 영상촬영에서 투과촬영 후 방출촬영의 위치변화에 따른 감쇠보정 불일치 시 감쇠보정 위치 변화 방법을 이용한 영상재구성법의 유용성에 대하여 평가하였다. GE Discovery STE16 장비에 스티로폼($20{\times}20{\times}10$ cm)의 중심점을 기준으로 x, y축 방향으로 ${\pm}2$, 6, 10 cm까지 1 mL 주사기 삽입 공간을 제작하였다. $^{18}F$-FDG 5 kBq/mL의 주사기를 중심점에서 투과촬영한 후 위치를 변화하여 방출촬영하고 위치 변화에 따른 감쇠보정 방법을 사용하여 영상을 얻었다. 재구성 방법은 반복영상 재구성법으로 반복횟수 2회, 부분집합 수 20을 적용하였으며 모든 방출촬영 데이터는 시간경과에 따른 붕괴보정을 적용하였다. 또한 주사기 위치에 관심영역을 설정한 후 방사능 값(kBq/mL)과 중심점에 대한 각 위치에서의 백분율 오차를 비교하였다. 방출영상의 중심점의 방사능 값은 2.30 kBq/mL이며, +x축 1.95, 1.82, 1.75 kBq/mL, -x축 2.07, 1.75, 1.65 kBq/mL, +y축 2.07, 1.87, 1.90 kBq/mL, -y축 2.17, 1.85, 1.67 kBq/mL로 나타났고, 백분율 오차는 +x축 15, 20, 23%, -x축 9, 23, 28%, +y축 12, 21, 20%, -y축 8, 22, 29%로 산출 되었다. 그리고 방출 영상에서 감쇠보정 위치변화 방법을 사용 하였을 경우 +x축 2.00, 1.95, 1.80 kBq/mL, -x축 2.25, 2.15, 1.90 kBq/mL, +y축 2.07, 1.90, 1.90 kBq/mL, -y축 2.10, 2.02, 1.72 kBq/mL로 나타났으며, 백분율 오차는 +x축 13, 15, 21%, -x축 2, 6, 17%, +y축 9, 17, 17%, -y축 8, 12, 25%로 산출 되었다. 감쇠보정 불일치 시 감쇠보정 위치변화 방법을 사용한 경우의 방사능 농도 값은 x, y축에서 평균 0.14, 0.03 kBq/mL 증가 하였고, 백분율 오차는 6.1, 4.2% 향상되었다. 또한 중심으로부터 멀어질수록 공간분해능이 저하되는 특성상 중심에서 먼 위치일수록 방사능 값의 저하현상은 커짐을 알 수 있었다. 그러나 실제 임상에서는 감약 정도가 더 커지기 때문에 이러한 불일치 시 그 오차는 더 클 것으로 사료된다. 따라서 감쇠보정이 일치하지 않는 부분의 병변에서는 감쇠보정 위치변화 방법을 적용하여 방사능 값의 오차를 감소시킬수 있을 것이다.

  • PDF