• 제목/요약/키워드: AC stress

검색결과 259건 처리시간 0.024초

A Study on Thermal Deformations of AC7A Tire Mold Casting Material by Pre-Heating Temperatures of Permanent Casting System (금형주조장치의 예열온도에 따른 타이어 몰드용 AC7A 주조재의 열변형에 관한 연구)

  • Choi, Je-Se;Choi, Byung-Hui
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제14권6호
    • /
    • pp.2596-2603
    • /
    • 2013
  • The precision and endurance of tire mold are very important factors to decide the quality of tire. However, the investigation on the thermal deformation of tire mold has a lot of trouble because the tire mold is produced in airtight permanent casting material. In this study, the thermal deformations such as temperature, displacement and stress distributions inside the AC7A tire mold casting material were analyzed by numerical analysis according to the preheating temperature of permanent casting device. In order to verify the results of numerical analysis, the experiments for temperature measurement of the AC7A casting material were carried out under the same condition with numerical analysis. For the numerical analysis, "COMSOL Multiphysics" was used. The preheating temperatures were set up $150^{\circ}C$, $200^{\circ}C$, $250^{\circ}C$ and $300^{\circ}C$, respectively. The thermal deformations were calculated in each case. When the preheating temperature is $300^{\circ}C$, displacement and stress are the lowest with 0.25mm and 0.351GPa, but the temperature is the highest with $374.27^{\circ}C$. When the experimental results were compared with the numerical results, there were some temperature differences because of the latent heat by phase change heat transfer. However, the cooling patterns were almost similar except for the latent heat section.

Effect of Tire Contact Stresses on Tensile Strains in the Surface of Thin Asphalt Pavement (접지압력이 앎은 아스팔트포장 표층 인장 변형률에 미치는 영향 분석)

  • Park, Dae-Wook;Park, Joon-Kyu
    • International Journal of Highway Engineering
    • /
    • 제10권2호
    • /
    • pp.47-55
    • /
    • 2008
  • In this paper, comparisons are presented on the predicted tensile strains which can affect the fatigue life of a thin asphalt concrete (AC) pavement near the surface of pavement from three-dimensional (3D) finite element (FE) using 3D measured tire contact stresses of a radial tire and a bias ply tire and a layered linear elastic program (BISAR). The objective was to analyze the stress distributions for a 11R22.5 radial tire and a $10{\times}20$ bias ply tire, and to compare the predicted tensile strains at the top and bottom of AC surface using different analysis methods. The results show that the stress distributions of two tires are similar but the 11R22.5 radial tire has much higher vertical contact stress than that of the $10{\times}20$ bias ply tire. The predicted tensile strains at the bottom of AC layer under the center of tire showed higher value by BM (BISAR with the measured contact area) method, which the measured tire contact area is used in a layered elastic program, while the tensile strain at the top of AC surface of 3.5cm offset distance from tire edge by 3D FE analysis showed the highest values among three analysis methods.

  • PDF

A Study on the High Power-Factor AC/DC converter using Resonant Auxiliary Circuit (공진형 보조 회로를 이용한 고역률 AC/DC 컨버터에 관한 연구)

  • Han, Dae-Hee;Kim, Yang;Baek, Soo-Hyun;Bae, Jin-Yang;Kim, Pil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1110-1113
    • /
    • 2002
  • A Single-Stage Single-Switch power-factor- correction(PFC) AC/DC Converter with universal input is presented in this paper. The PFC Converter can be achieved based upon the continuous current mode(CCM). The switch has less current and voltage stresses over a wide range of load variation so that a low voltage rating device can be used. The presented converter features high power factor high efficiency, and low cost. An 90W prototype was implemented to show that it has 70% efficiency with low voltage stress over universal line input.

  • PDF

Performance Evaluation of Seismic Stopper using Structural Analysis and AC156 Test Method

  • Ryu, Hyun-su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제26권3호
    • /
    • pp.277-285
    • /
    • 2020
  • Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.

AC-DC Converter with 500W class for Plasma display panel (플라즈마 디스플레이용 500W급 AC-DC 컨버터)

  • Kang, Won-Suck;Ahn, Tae-Yuong
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.139-142
    • /
    • 2004
  • Recently the PDP is the most remarkable media for a next generation display device. In this paper, we proposed the PDP dedicated AC-DC converter using quasi resonant method because the PDP has a lot of power dissipation so we need to develope. The proposed converter using one transformer has soft switching and a advantage to lower voltage stress in switch and also is predicted to have high power efficiency, we proposed the principles and theory using the zero voltage switching and verified the validity through a experiment.

  • PDF

A Single-Stage PFC AC/DC Forward Converter With Semi-automatic Current Shaping (전류 불연속 모드로 동작하는 1단 방식의 역률 보상 AC/DC 포워드 컨버터)

  • 강필순;김원호;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.319-322
    • /
    • 1999
  • This paper presents a novel single-stage Power Factor Corrected(PFC) AC/DC forward converter with semi-automatic current shaping in order to achieve the unity power factor and an isolated output. Since the proposed circuit is combined a boost converter used for PFCs with a forward converter used for DC to DC conversion, the over-all size of system could be reduced. And thanks to the zero voltage switching(ZVS) in both switches, the voltage stress can be reduced considerably. A simple auxiliary circuit adopted into the secondary of transformer is composed of lossless components for reducing surge voltage. A prototype which has tow IGBT(Insulated Gate Bypolar Transistor) modules as switching device is manufactured to evaluate the proposed topology. The characteristics of the proposed circuit are tested, and the validity is verified by experimental results.

  • PDF

High Power Factor High Efficiency PFC AC/DC Converter for LCD Monitor Adapter (LCD 모니터의 어댑터를 위한 고역률 고효율 PFC AC/DC 컨버터)

  • Park K. H.;Kim C. E.;Youn M. J.;Moon G. W.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.85-89
    • /
    • 2003
  • Many single-stage PFC(power-facto.-correction) ACHC converters suffer from the high link voltage at high input voltage and light load condition. In this paper, to suppress the link voltage, a novel high power factor high efficiency PFC AC/DC converter is proposed using the single controller which generates two gate signals so that one of them is used far gate signal of the flyback DC/DC converter switch and the other is applied to the Boost PFC stage. A 130w prototype for LCD monitor adapter with universal input $(90-265V_{rms})$ and 19.5V 6.7A output is implemented to verify the operational principles and performances. The experimental results show that the maximum link voltage stress is about 450V at 270Vac input voltage. Moreover, efficiency and power factor are over $84\%$ and 0.95, respectively, under the full load condition.

  • PDF

A Three-Phase AC-DC High Step-up Converter for Microscale Wind-power Generation Systems

  • Yang, Lung-Sheng;Lin, Chia-Ching;Chang, En-Chih
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1861-1868
    • /
    • 2016
  • In this paper, a three-phase AC-DC high step-up converter is developed for application to microscale wind-power generation systems. Such an AC-DC boost converter prossessess the property of the single-switch high step-up DC-DC structure. For power factor correction, the advanced half-stage converter is operated under the discontinuous conduction mode (DCM). Simulatanously, to achieve a high step-up voltage gain, the back half-stage functions in the continuous conduction mode (CCM). A high voltage gain can be obtained by use of an output-capacitor mass and a coupled inductor. Compared to the output voltage, the voltage stress is decreased on the switch. To lessen the conducting losses, a low rated voltage and small conductive resistance MOSFETs are adopted. In addition, the coupled inductor retrieves the leakage-inductor energy. The operation principle and steady-state behavior are analyzed, and a prototype hardware circuit is realized to verify the performance of the proposed converter.

Hot-Carrier-Induced Degradation in Submicron MOS Transistors (Submicron MOS 트랜지스터의 뜨거운 운반자에 의한 노쇠현상)

  • 최병진;강광남
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • 제25권7호
    • /
    • pp.780-790
    • /
    • 1988
  • We have studied the hot-carrier-induced degradation caused by the high channel electric field due to the decrease of the gate length of MOSFET used in VLSI. Under DC stress, the condition in which maximum substrate current occures gave the worst degradation. Under AC dynamic stress, other conditions, the pulse shape and the falling rate, gave enormous effects on the degradation phenomena, especially at 77K. Threshold voltage, transconductance, channel conductance and gate current were measured and compared under various stress conditions. The threshold voltage was almost completely recovered by hot-injection stress as a reverse-stress. But, the transconductance was rapidly degraded under hot-hole injection and recovered by sequential hot-electron stress. The Si-SiO2 interface state density was analyzed by a charge pumping technique and the charge pumping current showed the same trend as the threshold voltage shift in degradation process.

  • PDF

Effect of Different Cooling System on Performance and Hair Cortisol on Sows under Heat Stress (고온기 분만사 내 냉방 시설의 종류가 모돈의 번식성적 및 스트레스 지표에 미치는 영향)

  • Oh, Seung-Min;Choi, Yo-Han;Kim, Dong-Woo;Ha, Sang-Hun;Kim, Jo-Eun;Jung, Hyun-Jung;Kim, Jin-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제22권3호
    • /
    • pp.160-168
    • /
    • 2021
  • This study was undertaken to determine the effect of different cooling systems on the performance and hair cortisol of sows under heat stress. During a 21-day experiment, a total of 40 multiparous sows (Landrace×Yorkshire; 242.84±2.89 kg) were allotted to 4 treatments, each with 10 replicates (1 sow per pen). The experimental treatments were CP (Cooling pad), AC (Air conditioner), SC (Snout cooling), and MS (Mist spray). We observed an increase in the average daily feed intake during lactation (p<0.05) in the CP and AC treatment groups. AC treatment had the highest (p<0.05) and SC treatment had the lowest (p<0.05) piglet weight at weaning. During lactation, sows administered SC and MS treatments had higher (p<0.05) hair cortisol accumulation, as compared with the AC and CP treatments. Hair cortisol accumulation in piglets during lactation was highest with MS treatment (p<0.05), and lowest after CP treatment (p<0.05). MS treatment had the highest (p<0.05), and AC treatment had the lowest (p<0.05) respiratory rate and rectal temperature during lactation. In conclusion, our results indicate that a cooling pad and air conditioning cooling system increases the productivity of a sow, as compared to snout cooling and mist spray cooling systems.