• Title/Summary/Keyword: AC stress

Search Result 259, Processing Time 0.027 seconds

The Electrical Properties of Mini-model Cable under mechanical stress in Liquid Nitrogen (액체질소 중에서 기계적 응력에 따른 mini-model 케이블의 전기적 특성)

  • 김영석;곽동순;한철수;김해종;성기철;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.22-27
    • /
    • 2004
  • It is important to mechanical properties of dielectric paper and cable to optimum electrical insulation design of HTS cable, because the cable has experience of mechanical stress, such as tensile stress, bending stress. Also, it is operated at cryogenic temperature. From the results, it was observed that the tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen is decreased. Because PPLP was deteriorated by microcrack and tensile strain. According as bending radius multiple is decrease, the ac and impulse breakdown stress of mini-model cable is sharply decreased.

Study on the Address Discharge Characteristics for the Improvement of the Mis-firing Problem in AC PDP (AC PDP의 오방전 개선을 위한 어드레스 방전 특성 연구)

  • Jeon, Won-Jae;Kim, Dong-Hun;Lee, Seok-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1151-1156
    • /
    • 2009
  • Unstable sustain discharges can occur at the bottom cells of the panel at high temperature. To solve this problem, the wall charge variation during an address period was investigated. A test panel of 7.5 inch XGA level was used and one green cell was measured. In order to realize operating condition equal to that of the bottom cells of 50 inch panel, the addressing stress pulses are applied. It seems that the resultant wall charge loss during address period increased with increase of stress time, temperature, pressure and Xe %. Wall charge loss increases with potential difference between scan electrode and address electrode, therefore wall charge loss can be minimized by the increase of scan voltage during address period.

Measurement of AC Hysteresis Loops under Variable Tensile Stress for Amorphous Wire (비정질 세선의 인장응력에 따른 교류자기이력 특성측정)

  • 조희정;양종만;손대락;김구영
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.1
    • /
    • pp.61-64
    • /
    • 1993
  • We have constructed a hysteresis loop tracer in order to measure the magnetic properties of amorphous wires under variable tensile stress. It has a force range of 0 N to 20 N and a magnetizing frequency of 1 kHz to 20 kHz. Using the ac-hysteresis loop tracer, we can measure the magnetic properties(maximum magnetic induction $B_{max}$, residual magnetic induction $B_{r}$, coercive field strength $H_{c}$, etc.) of amorphous wires with precision of 1% under variable tensile stresses.

  • PDF

A Study on Fatigue Life and Fatigue Crack Propagation Behavior of MMC (MMC의 피로수명과 피로균열전파거동에 관한 연구)

  • 허선철;박원조;최용범
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.127-133
    • /
    • 2002
  • The objective of this study is to investigate fatigue life and fatigue crack propagation behavior The experiment of fatigue life for MMC have been carried out for the stress ratio R=0.1 at 20Hz. Fatigue lift limit of AC4CH alloy is about 70 ㎫ and Fatigue limit of MMC has been increment to 120 ㎫, therefore, fatigue limits of MMC is about 71 % higher than that of AC4CH alloy Crack propagation tests on half-size CT specimen of thickness 12.5mm were conducted by using sinusoidal waveform. The crack length was monitored by compliance method. Test conditions were at 0.1 and 0.05 of load ratio at 10Hz of loading frequency and test load was 2.3kN. The effects of stress ratio on the fatigue crack propagation behavior for MMC was discussed within the Paris law. As the results of this study, Fatigue crack propagation increased with increasing the load ratio.

Effects of Pre-formed Space Charges by Negative DC Voltages on PD Characteristics in XLPE (부극성 직류전압에 의해 사전 형성된 공간전하가 XLPE의 부분방전특성에 미치는 영향)

  • 황보승;이준호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.7
    • /
    • pp.310-313
    • /
    • 2003
  • The purpose of this paper is to evaluate the effects of pre-formed space charges by DC stress on partial discharge(PD) characteristics in XLPE. We have suggested a modified pulsed electro-acoustic(PEA) method and successfully measured both space charge distribution and current simultaneously. It has been demonstrated that the PD patterns are strongly influenced by the pre-formed space charge distributions, which are hardly disappeared up to AC 8㎸ in electrode configuration including air gap between XLPE layer and electrode. From the results, it could be said that the pre-formed space charges by DC stress can play harmful and dangerous roles in insulating system under AC operating voltages because of the field distortion and localization due to the pre-formed space charge.

A Novel Soft Switching PWM·PFC AC·DC Boost Converter

  • Sahin, Yakup
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.256-262
    • /
    • 2018
  • This study introduces a novel Soft Switching (SS) Pulse Width Modulated (PWM) AC-DC boost converter. In the proposed converter, the main switch is turned on with Zero Voltage Transition (ZVT) and turned off with Zero Current Transition (ZCT). The main diode is turned on with Zero Voltage Switching (ZVS) and turned off with Zero Current Switching (ZCS). The auxiliary switch is turned on and off with ZCS. All auxiliary semiconductor devices are turned on and off with SS. There is no extra current or voltage stress on the main semiconductor devices. The majority of switching energies are transferred to the output by auxiliary transformer. Thus, the current stress of auxiliary switch is significantly reduced. Besides, the proposed converter has simple structure and ease of control due to common ground. The theoretical analysis of the proposed converter is verified by a prototype with 100 kHz switching frequency and 500 W output power. Furthermore, the efficiency of the proposed converter is 98.9% at nominal output power.

Dual Path Magnetic-Coupled AC-PDP Sustain Driver with Low Switching Loss

  • Lee Jun-Young
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.205-213
    • /
    • 2006
  • A cost-effective magnetic-coupled AC-PDP sustain driver with low switching loss is proposed. The transformer reduces current stress in the energy recovery switches which affects circuit cost and reliability. The turns-ratio can be used to adjust the sustain pulse slopes which affect gas discharge uniformity. Dividing the recovery paths prevents abrupt changes in the output capacitance and thereby switching losses of the recovery switches is reduced. In addition, the proposed circuit has a more simple structure because it does not use the recovery path diodes which also afford a large recovery current. By reducing the current stress and device count in the energy recovery circuit, the proposed driver may have decreased circuit cost and improved circuit reliability.

Study on the Address Discharge Characteristics for the Analysis of the Unstable Discharge in AC PDP (AC PDP의 오방전 원인 분석을 위한 어드fp스 방전 특성에 관한 연구)

  • Kim, Dong-Hun;Jeon, Won-Jae;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.214-215
    • /
    • 2007
  • Unstable sustain discharges can occur at the bottom cells of the panel at high temperature. To solve this phenomenon, the wall charge variation during an address period was investigated. A test panel of 7.5 inch XGA level was used and one green cell was measured. In order to realize operating condition equal to that of the bottom cells of 50 inch panel, the addressing stress pulses are applied. It seems that the resultant wall charge loss during address period increased with increase of temperature as well as the addressing stress pulse voltage. Therefore it results in unstable discharge during sustain period.

  • PDF

A Study on the Aging Behavior of Ship Organic Coating by the Flow Induced Shear Stress (유동 전단응력에 의한 선박 유기도막의 열화거동 연구)

  • Park Hyun;Park Jin-Hwan;Ha Hyo-Min;Chun H.H.;Lee In-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.1 s.24
    • /
    • pp.9-14
    • /
    • 2006
  • Analysis has been made of the anti-corrosive property of organic coating under the shear stress of the flow by means of AC impedance method. Marine anti-corrosive painted panels were placed in the water channel with varying flow rate, thereby experiencing varying flow shear stress on the surfaces. The velocities of the salt water were ranged from 1.48 to 5.2 m/s and the coating thickness of from $70{\mu}m\;to\;140{\mu}m$. For all coating thicknesses investigated, the poorer anti-corrosive property and the lower adhesion strength have been found for the higher shear stress. It has been found that the shear stress accelerates the aging of organic marine coatings.

  • PDF

The Antiulcer Effects of Alove vera on the Stomach ulcer Induced by Stress in rats (흰쥐의 스트레스성 위궤양에 대한 Alove vera의 항궤양작용)

  • 박은지;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.3
    • /
    • pp.175-184
    • /
    • 1994
  • This was performed to investigate the antiulcer effects of Aloe vera on the stomach ulcer induced by restraint and water-immersion stress in rats. For this experiment, 60 male Sprague-Dawley strain were used. The experimental groups were divided into five: a control(CA) and 4 aloe treatment groups. Each dose of aloe was 50 mg/kg BW(AA), 100mg/kg BW(AB), 200 mg/kg BW(AC), and 400 mg/kg BW(AD). The rats were allocated to each group by 12 and observed for 4 weeks. The results are as following. 1. The stomach surface pH in each group showed no significant difference, byt the values of aloe treatment groups were higher than the value of the control group. 2. The gastric wall mucus was significantly increased in all aloe treatment groups(p<0.05) compared with the control group. Especially in AC and AD group the differences were higher(p<0.01). 3. At shear rate rate 11.25, 45.0, 90.0, 225.0 sec-1, whole blood viscosity and plasma viscosity were measured. Most of the values of aloe treatment groups were significantly low compared with those of the control group(P<0.05). 4. The ulcer index of aloe treatment groups were significantly low campared with control group(p<0.05). Especially in AC and AD group the differences were more significant(p<0.01). 5. Less severe ulcers were observed in AA and AB group than in the control group. Tissues of AC and AD group had only slight ulcers and necrosis of tissue was not observed in these groups. Especially in AD group, there was more mucus than other groups and it seemed that alove vera stimulated the epithelial regeneration. From the results of this study, it can be concluded that the oral administration of Alove vera results in protection of stomach ulcer by stimulating the secretion of gastric mucus and the circulation of blood.

  • PDF