• Title/Summary/Keyword: AC sensitivity

Search Result 109, Processing Time 0.027 seconds

A Study on the Change of Contrast Sensitivity with Breath Alcohol Concentration in Various Luminance (다양한 휘도에서 호흡 알코올 농도에 따른 대비감도 변화 연구)

  • Nam, Soo-Kyung;Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.505-511
    • /
    • 2014
  • Purpose: This study was to investigate the effect of breath alcohol concentration (BrAC) increase with drinking alcohol on contrast sensitivity in the conditions of restricted BrAC. Methods: 23 males in 20s (average age $21.17{\pm}2.19$ years, body mass index (BMI) $22.09{\pm}2.16$) were selected and administered the amount of alcohol to reach 0.05% and 0.08% BrAC calculated by BAC (blood alcohol concentration) Dosing Software program, which was developed as basis of Watson's formula. Then, the contrast sensitivity in various luminance conditions (photopic, mesopic, and mesopic with glare) was measured and compared between these conditions. Results: The contrast sensitivity in all spatial frequency was decreased with BrAC increase. Although BrAC was increased, the peak of contrast sensitivity didn't change as 6 cycle per degree (cpd) in the photopic condition and 3 cpd in the mesopic condition, respectively. But, in the mesopic condition with glare, the peak of contrast sensitivity was shifted from 6 cpd at 0% and 0.05% BrAC to 3 cpd at 0.08% BrAC with increase of alcohol concentration. Conclusions: The increase of BrAC by drinking alcohol induces the decrease of contrast sensitivity in all spatial frequency and the shift of peak of contrast sensitivity, which can cause safety accidents, and may have an effect on various visual tasks.

Sensitivity Analysis for Reliability Prediction Standard: Focusing on MIL-HDBK-217F, RiAC-HDBK-217Plus, FIDES (신뢰도 예측 규격의 민감도 분석: MIL-HDBK-217F, RiAC-HDBK-217Plus, FIDES를 중심으로)

  • Oh, JaeYun;Park, SangChul;Jang, JoongSoon
    • Journal of Applied Reliability
    • /
    • v.17 no.2
    • /
    • pp.92-102
    • /
    • 2017
  • Purpose: Reliability prediction standards consider environmental conditions, such as temperature, humidity and vibration in order to predict the reliability of the electronics components. There are many types of standards, and each standard has a different failure rate prediction model, and requires different environmental conditions. The purpose of this study is to make a sensitivity analysis by changing the temperature which is one of the environmental conditions. By observing the relation between the temperature and the failure rate, we perform the sensitivity analysis for standards including MIL-HDBK-217F, RiAC-HDBK-217Plus and FIDES. Methods: we establish environmental conditions in accordance with maneuver weapon systems's OMS/MP and mission scenarios then predict the reliability using MIL-HDBK-217F, RiAC-HDBK-217Plus and FIDES through the case of DC-DC Converter. Conclusion: Reliability prediction standards show different sensitivities of their failure rates with respect to the changing temperatures.

Development of High Sensitivity Actuator for Flexible Disk (유연 디스크를 위한 고감도 엑추에이터 개발)

  • Song, Myeong-Gyu;Kim, Choong;Lee, Dong-Joo;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.577-580
    • /
    • 2005
  • This paper reports the high sensitivity actuator for flexible disk. The air stabilized flexible optical disk has very small axial runout. Therefore, It is proper to develop an actuator which has high sensitivity in tracking direction rather than in focusing direction. In order to maximize driving force in radial direction, we present an efficient design of magnetic circuit with simple multi-polarized magnets and auxiliary magnets. Designed magnetic circuit has big force in tracking direction. And we shift 2$^{nd}$ resonance frequency of moving parts Into high frequency band, not causing increase of mass and discord between force and mass centers to secure high sensitivities and sufficient control bandwidth. Finally, experimental results show that designed actuator has superior sensitivity in tracking direction.

  • PDF

An Economic Analysis of Potential Cost Savings from the Use of Low Voltage DC (LVDC) Distribution Network

  • Hur, Don;Baldick, Ross
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.812-819
    • /
    • 2014
  • The proposed technical work attempts to compare the two key technologies of power distribution, i.e. direct current (DC) and alternating current (AC) in a fiscal manner. The DC versus AC debate has been around since the earliest days of electric power. Here, at least four types of a low voltage DC (LVDC) distribution are examined as an alternative to the existing medium voltage AC (MVAC) distribution with an economic assessment technique for a project investment. Besides, the sensitivity analysis will be incorporated in the overall economic analysis model to cover uncertainties of the input data. A detailed feasibility study indicates that many of the common benefits claimed for an LVDC distribution will continue to grow more profoundly as it is foreseen to arise with the increased integration of renewable energy sources and the proliferation of energy storage associated with the enhanced utilization of uninterruptible power supply (UPS) systems.

Evaluation of Microbial Load in Oropharyngeal Mucosa from Tannery Workers

  • Castellanos-Arevalo, Diana C.;Castellanos-Arevalo, Andrea P.;Camarena-Pozos, David A.;Colli-Mull, Juan G.;Maldonado-Vega, Maria
    • Safety and Health at Work
    • /
    • v.6 no.1
    • /
    • pp.62-70
    • /
    • 2015
  • Background: Animal skin provides an ideal medium for the propagation of microorganisms and it is used like raw material in the tannery and footware industry. The aim of this study was to evaluate and identify the microbial load in oropharyngeal mucosa of tannery employees. Methods: The health risk was estimated based on the identification of microorganisms found in the oropharyngeal mucosa samples. The study was conducted in a tanners group and a control group. Samples were taken from oropharyngeal mucosa and inoculated on plates with selective medium. In the samples, bacteria were identified by 16S ribosomal DNA analysis and the yeasts through a presumptive method. In addition, the sensitivity of these microorganisms to antibiotics/antifungals was evaluated. Results: The identified bacteria belonged to the families Enterobacteriaceae, Pseudomonadaceae, Neisseriaceae, Alcaligenaceae, Moraxellaceae, and Xanthomonadaceae, of which some species are considered as pathogenic or opportunistic microorganisms; these bacteria were not present in the control group. Forty-two percent of bacteria identified in the tanners group are correlated with respiratory diseases. Yeasts were also identified, including the following species: Candida glabrata, Candida tropicalis, Candida albicans, and Candida krusei. Regarding the sensitivity test of bacteria identified in the tanners group, 90% showed sensitivity to piperacillin/tazobactam, 87% showed sensitivity to ticarcillin/clavulanic acid, 74% showed sensitivity to ampicillin/sulbactam, and 58% showed sensitivity to amoxicillin/clavulanic acid. Conclusion: Several of the bacteria and yeast identified in the oropharyngeal mucosa of tanners have been correlated with infections in humans and have already been reported as airborne microorganisms in this working environment, representing a health risk for workers.

Characteristics of AC Hot-carrier-induced Degradation in nMOS with NO-based Gate Dielectrics (NO기반 게이트절연막 NMOS의 AC Hot Carrier 특성)

  • Chang, Sung-Keun;Kim, Youn-Jang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.586-591
    • /
    • 2004
  • We studied the dependence of hot-tarrier-induced degradation characteristics on nitrogen concentration in NO(Nitrided-Oxide) gate of nMOS, under ac and dc stresses. The $\Delta$V$_{t}$ and $\Delta$G$_{m}$ dependence of nitrogen concentration were observed, We observed that device degradation was suppressed significantly when the nitrogen concentration in the gate was increased. Compared to $N_2$O oxynitride, NO oxynitride gate devices show a smaller sensitivity to ac stress frequency. Results suggest that the improved at-hot carrier immunity of the device with NO gate may be due to the significantly suppressed interface state generation and neutral trap generation during stress.ess.

CO Sensor Characteristics of ZnO powders by Sol-Gel methods (Sol-Gel법에 의한 ZnO 분말의 CO 센서 특성)

  • Park, Bo-Seok;Park, Jin-Seoung;Noh, Whyo-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.821-825
    • /
    • 2002
  • ZnO thick films by Sol-Gel processing were investigated electrics, optics and the sensing characteristics of CO gas. Using the znic acetate dihydrate and acetylaceton (AcAc) as a chelating agent, stable ZnO sol was synthesized. ZnO phase was crystallized through the heat-treatment at $70^{\circ}C$ for 4hrs and influenced the sensing characteristics of the electrics and CO gas by uniform particle distributions not related particle size. The samples on the alumina substrate by thick films were investigated the properties of electrics and the effect of sensing. The sensitivity was so excellent in the sample of the heat-treatment at $600^{\circ}C$ for 12hrs and good in the heat-treatment for 1hrs generally. Crystallization and volatilization of organic materials according to the change of heating treatment temperature of thick films were analyzed by TG-DTA, XRD and mirostructure of thick films were observed by SEM.

  • PDF

The Enhancement of Power System Security Using flexible AC Transmission Systems (FACTS) (FACTS 기기를 이용한 전력시스템의 안전도 향상)

  • 송성환;임정욱;문승일
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.165-172
    • /
    • 2003
  • This paper presents an operation scheme to enhance the power system security by applying FACTS on Power systems. Three main generic types of FACTS devices are suggested an illustrated. Flow congestions over lines have been solved by controlling active power of series-compensated FACTS devices and low voltages at buses have been solved by controlling reactive power of shunt-compensated FACTS devices. Especially, Especially, UPFC has been applied in both line congestion and low voltages. Two kinds of indices which indicate the power system security level related to line flow and bus voltage are utilized in this paper. They have been minimized to enhance the power system security level through the iterative method and the sensitivity vector of security index is derived to determine the direction to minimum. The proposed algorithm has been tested on the IEEE 57-bus system with FACTS devices in a normal condition and a line-faulted contingency.

A Magnetic Microsensor based on the Hall Effect in an AC Microplasma (극미세 교류 플라즈마 내에서의 홀 효과를 이용한 마이크로 자기센서)

  • Seo, Young-Ho;Han, Ki-Ho;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1266-1272
    • /
    • 2003
  • This paper presents a new class of magnetic microsensors based on the Hall effect in AC microplasma. In the theoretical study, we develop a simple model of the plasma Hall sensor and express the plasma Hall voltage as a function of magnetic field, plasma discharge field, pressure, and electrode geometry. On this basis, we have designed and fabricated magnetic microsensors using AC neon plasma. In the experiment, we have measured the Hall voltage output of the plasma microsensors for varying five different conditions, including the frequency and the magnitude of magnetic field, the frequency and the magnitude of plasma discharge voltage, and the neon pressure. The fabricated magnetic microsensors show a magnetic field sensitivity of 8.87${\pm}$0.18㎷/G with 4.48% nonlinearity.

Dynamic characteristics of optical pickup actuator with a newly designed electromagnetic circuit (신 자기회로가 적용된 광픽업 액추에이터의 동특성)

  • Park, Kwan-Woo;Kim, Jae-Eun;Jung, Jae-Hyun;Lee, Kyung-Taek;Ko, Eui-Seok;Hoon, Min-Byung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.512-514
    • /
    • 2008
  • In this paper, a new electromagnetic circuit is proposed for an optical pickup actuator with high sensitivity. Contrary to those of conventional actuators, the proposed circuit has two focusing coils which are diagonally placed at the front and rear of a moving part. The configuration which makes the effective length of the focusing coil longer and the moving part lighter, is helpful in increasing the sensitivity of the actuator. However, the asymmetry of the moving part by two focusing coils causes flexible node vibrations in quite low frequency range. This paper shows that the design modification of the moving part for the reconfiguration of mass moment of inertia can reduce the mode vibrations.

  • PDF