• Title/Summary/Keyword: AC network system

Search Result 167, Processing Time 0.025 seconds

S-Domain Equivalent System for Electromagnetic Transient Studies PART II : Frequency Dependent AC System Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART II: 주파수 의존 교류 시스템 등가)

  • Chung Hyeng-Hwan;Wang Yong-Peel
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.165-171
    • /
    • 2005
  • Electromagnetic transient simulation can be used to model complex non-linearities that very difficult to represent adequately in the frequency domain. This problem is greatly reduced with the use of frequency dependent network equivalents for the linear part of the system. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper presents the formulation for developing 2 port Frequency Dependent AC System Equivalent(FDACSE) with the instantaneous term in S-domain and illustrates its use. This 2 port FDNE have been applied to the New Zealand AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 2 port (FDACSE) developed with Norton Equivalent network. The study results have indicated the robustness and accuracy of 2 port FDACSE for electromagnetic transient studies.

A Study on the Parameter Determination of Synchronous Compensator in AC network with HVDC system (HVDC계통에서 동기조상기의 파라미터 선정에 관한 연구)

  • Lee, Seok-Jin;Lee, Heung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1353-1359
    • /
    • 2010
  • This paper presents the determination of synchronous compensator(S.C) rating and parameter in Cheju AC network. The role of S.C is to supply Inertia and reactive power to HVDC system which is a kind of a generator without the function of reactive power control and Inertia. Therefore, the parameters of S,C have to be determined by considering HVDC operating characteristics. The background of this paper is the determination of S.C parameters in Cheju AC network in the case of replacing current operating S,C to new S.C type.

Operation Strategy of Cheju AC Network Included Multi-Infeed HVDC System

  • Kim, Chan-Ki;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.393-401
    • /
    • 2013
  • This paper deals with the operation strategy of the Cheju AC network included MIHVDC system (Multi-Infeed HVDC system). In case that where several HVDC systems are located in the vicinity of each other, there are interactions between the different HVDC systems in such network configurations. The interactions which could be generated in multi-infeed HVDC are voltage stability, power stability and inertia stability, to analyze such systems in a systematic way to ensure that there are no risks of adverse interactions is very important. The developed method until now to analyze MIHVDC interaction is extended from MAP(Maximum Available Power) method for analyzing the power stability of the single-infeed HVDC system, this method is to solve the eigenstructure using the identified factors influencing the interactions. Finally, the algorithms which are introduced in this paper, to determine the operation strategy are applied to Cheju island network which is supplied by two HVDCs.

Speed Control of AC Servo Motor Using Neural Network (교류 서보 전동기의 속도제어를 위한 뉴러퍼지 관측기설계)

  • Ban, Gi-Jong;Kim, Lark-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.4
    • /
    • pp.158-160
    • /
    • 2006
  • In this paper, a neuro-fuzzy observer system is designed using neuro-fuzzy system for speed control of AC servo motor. This neuro-fuzzy observer is proposed to with the problems occur in the Luenberger observer and sliding observer. The problems of Luenberger and sliding observer are to have to know the dynamics and internal parameters of the system. Performance of the neuro-fuzzy observer system has verified through the experiment with dynamometer load. It is shown that feasibility of the neuro-fuzzy observer is verified.

New HVDC Interaction between AC networks and HVDC Shunt Reactors on Jeju Converter Stations

  • Kim, Chan-Ki;Kwon, Young-Hun;Jang, Gil-Soo
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.233-237
    • /
    • 2007
  • This paper deals with the new HVDC interaction which was observed in the Jeju-Haenam HVDC system. The interaction is not from a system malfunction or controller loop problem but from the change of AC network scheme and the network operating condition. We have found that the interaction is caused by the voltage oscillation between synchronous compensator and HVDC shunt reactor. We analyzed the cause of the interaction and suggested a solution.

The Analysis of Protection -Characteristics and Fault-Locator Simulation on the Electrical Railway (교류전기철도 보호특성 해석 및 고장점표정 시뮬레이션)

  • 창상훈;이장무
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.262-269
    • /
    • 1998
  • In case the fault occurs in AC power supply network, protective relaying system must selectively detect line-to-line/ground fault and immediately cut off the power flow into the fault location for guaranteeing the safety of people, electric vehicle and ground installation etc. It is the most important point in power system operation to minimize the fault duration by rapid trip scheme and accurate estimation of the fault location. In this paper, we analyze the load characteristics of each vehicle, perform the fault analysis of AC power supply network using AT current-ratio method. The result shows its usefulness.

  • PDF

Jeju 80kV HVDC Controller Modeling Using PSCAD/EMTDC Program (PSCAD/EMTDC 프로그램을 이용한 제주 80kV HVDC 제어기 모델링)

  • Choi, Soon-Ho;Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.533-541
    • /
    • 2011
  • This paper studies modeling of Jeju 80kV HVDC system and its controller by using PSCAD/EMTDC program. Reduced ac network is applied to verify interaction between ac network and dc system. Design parameter is applied to the converter transformer, harmonic filter and dc transmisstion line to simulate dc system. HVDC controller is divided into a rectifier controller and a inverter controller according to the converter operating mode. The inverter controller is composed of current control, voltage control and extingtion angle control. The rectifier controller is composed of current control and voltage control. Both controller has VDCOL characteristics so that current order is dependant on voltage variation. Step response, ac network single phase fault, three phase fault is simulated to verify the dynamic performance of controller model in both transient state and steady state.

A Study on the Control of AC Servo Motor for Machine Tools Cartesian Coordinate Type Using Neural Network (신경회로망을 이용한 평면좌표형 공작기계 교류서보전동기의 제어에 관한 연구)

  • 김평호;백형래;정수복
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.49-56
    • /
    • 2001
  • This paper presents a new approach to the problem based on neural network methods. Instead of using general controllers, neural networks PID control are used to control AC servo motor. The most popular and widely used control method in servo system control loops is PID type. PID controller has the features of simple structure, stability and reliability. But it has limitations in complex system control and can not remain above virtues under the conditions of parameters uncertain and environment uncertainties. AC servo motor controller is designed for drive of the cartesian coordinate type for machine tools.

  • PDF

Implementation of IEEE 802.11ac Down-link MU-MIMO WLAN MAC using Unified Design Methodology

  • Chung, Chulho;Jung, Yunho;Kim, Jaeseok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.719-727
    • /
    • 2016
  • This paper proposes a unified medium access control (MAC) design methodology and presents the implementation of the IEEE 802.11ac down-link multi-user multi-input and multi-output wireless local area network MAC using the proposed design methodology. The proposed methodology employs unified code for both network simulation and system implementation. Because the unified code closely relates these two processes, the performance of the implemented MAC system can be estimated before implementation. The MAC architecture for an access point implemented using the proposed design methodology is verified on an ARM-based platform, and it is applied to a 65 nm CMOS library.

Analysis of Switching Surge Over-voltage in AC/DC Hybrid Transmission Lines (AC/DC 병가선로의 개폐서지 과전압 해석)

  • Yoo, Seong-Soo;Shin, Koo-Yong;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.459-466
    • /
    • 2022
  • Switching surges are a common type of phenomenon that occur on any sort of power system network. These are more pronounced on long transmission lines and in high voltage converter stations. At AC/DC hybrid transmission lines, the insulation coordination of such lines is mainly dictated by the peak level of switching surges, the most dangerous of which include three phase line energization and AC/DC converter station. The power system structure consist of AC/DC hybrid transmission lines which is combination of AC 765kV and ±500kV HVDC 1 bipole system for contingency analysis. The power system under study and its components are simulated using EMTDC software package, the effects of the various AC/DC mixing power lines are reviewed. The developed models of EMTDC conversion lines based on combination of AC/DC system are simulated and the characteristics of switching surge over-voltage from its results are discussed.