• Title/Summary/Keyword: AC input voltage variation

Search Result 30, Processing Time 0.02 seconds

Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation (교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발)

  • Kim, Sung-An;Han, Sung-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.

Three-Phase AC-to-DC Resonant Converter Operating in High Power Factor Mode in High-Voltage Applications

  • Chaudhari, Madhuri A.;Suryawanshi, Hiralal M.;Kulwal, Abhishek;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.60-73
    • /
    • 2008
  • In this paper a three-phase ac-to-dc resonant converter with high input power factor and isolated output is proposed. To improve the input power factor of the converter, high frequency current is injected into the input of the three-phase diode bridge rectifier. It is injected through an impedance network consisting of a series of L-C branches from the output of the high frequency three-phase inverter. A narrow switching frequency variation is required to regulate the output voltage. A design example with different design curves is illustrated along with the component ratings. Experimental verification of the converter is performed on a prototype of 3 kW, 1000 V output, operating above 300 kHz. Experimental results confirm the concept of the proposed converter. Narrow switching frequency variation is required to regulate the output voltage.

Dimming Control System for Multi-Fluorescent Lamp Using AC Chopper Technique (AC Chopper를 이용한 다등용 조광제어 시스템에 관한 연구)

  • 정동열;박종연
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.4
    • /
    • pp.177-182
    • /
    • 2003
  • We have proposed the dimming controller using the AC chopper technique. The AC chopper changes the amplitude of the input source voltage with the same frequency. The conventional dimming controller is operated by controlling voltage phase with the triac. It has bad characteristics of the input current THD and the input power factor But the dimming controller using the ac chopper technique has a low current THD and a good power factor. The developed dimming controller is consist of the IGBT and the low pass filter. The system is operated by the variation circuit of the input source voltage and the microprocessor.

Dimming Control System for Multi-Fluorescent Lamp Using AC Chopper Technique (AC Chopper를 이용한 다등용 조광제어 시스템에 관한 연구)

  • 정동열;박종연
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.177-177
    • /
    • 2003
  • We have proposed the dimming controller using the AC chopper technique. The AC chopper changes the amplitude of the input source voltage with the same frequency. The conventional dimming controller is operated by controlling voltage phase with the triac. It has bad characteristics of the input current THD and the input power factor But the dimming controller using the ac chopper technique has a low current THD and a good power factor. The developed dimming controller is consist of the IGBT and the low pass filter. The system is operated by the variation circuit of the input source voltage and the microprocessor.

Output AC Voltage Control of a Three-Phase Z-Source Inverter by the Voltage Gain and Modulation Index Control (전압 이득과 변조지수 제어에 의한 3상 Z-소스 인버터의 출력 교류 전압 제어)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Yang, Seung-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1996-2005
    • /
    • 2010
  • This paper proposes a new method for constant control of the output AC voltage of a voltage-fed three phase Z-source inverter (ZSI), in case of Z-network DC voltage variation or heavy change of load. The modulation index for the reference output AC voltage of ZSI can be calculated by the basic definition of ZSI, the input DC voltage and capacitor voltage of Z-network. And, the output AC voltage of ZSI is controlled by the modified space vector modulation (SVM) with the calculated modulation index. By the proposed method, the modulation index of output AC voltage is closely following in the reference modulation index. The validity of the proposed method is verified using PSIM simulation. In case which the input DC voltage of ZSI is heavily changed from 100[V] to 70[V] (or to 150[V]) and in case which load is changed from $30[\Omega]$ to $10[\Omega]$, we confirmed that the output AC voltage of ZSI is constantly controlled by the proposed method because the modulation index of ZSI is also simultaneously changed. Finally, FFT and %THD of the output voltage and current of ZSI by the proposed method are analyzed.

The Single-Phase Voltage-Doubler AC-DC Converter by using a Boost Capacitor (승압용 커패시터를 이용한 단상 배전압 AC-DC 컨버터)

  • Jung, S.H.;Kim, S.D.;Lee, S.H.;Lee, H.W.;Chun, J.H.;Chung, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1103-1105
    • /
    • 2002
  • A conventional AC-DC boost converter has much variation of input current as more increased the load or output voltage by the hysterical control method that is comparing area of current pulse by using PWM method and integration to sinusoidal input current. To improve the problems. in this paper, we propose the single-phase voltage doubler AC-DC converter circuit using the capacitor for boost:confirm characteristics of normal and transition state by using simulation, be stabilized voltage of doubler capacitor for boost, and Identify to get the sinusoidal input current with unity power factor.

  • PDF

Sinusoidal Tracking Control of Voltage Source PWM Converter by Input Current Estimation (입력전류추정에 의한 전압형 PWM 컨버터의 정현추종제어)

  • 허태원;박지호;신동률;김춘삼;우정인
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.39-47
    • /
    • 2000
  • This paper presents the sinusoidal tracking controller in error to eliminate the steady state control error and to improve the transient characteristics for input current in voltage source PWM converter with input current estimation. The estimation method of input current values and configuration of controller are described. DC output voltage is controlled by PI controller, and sinusoidal tracking current controller which tracks directly AC input current is used as input current controller. The sinusoidal tracking current controller can be used without any coordinate transformation algorithms.It is proved that the steady state deviation of input current reduces to zero and the proposed control system is not affected by input voltage from transfer functions of input current control system. The validity of proposed scheme is verified by simulations and experimental results for load resister and input voltage variation.

  • PDF

Development of Dimming Control System for Fluorescent Lamp Using AC Chopper Technique (AC Chopper를 이용한 형광등의 조광제어 시스템의 개발)

  • 정동열;박종연
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.71-74
    • /
    • 2002
  • We have development the dimming controller using the ac chopper technique. The ac chopper change the amplitude of the input source voltage with the unchanged its frequency. The conventional dimming controller is operated by controlling voltage phase and is consist of the triac. It has a bad characteristic about a current THD and a power factor. But the dimming controller using the at chopper technique has a low current THD and a good power factor. The developed dimming controller is consist of the MOSFET and the low pass filter. The system is operated by the variation circuit of the input source voltage and the microprocessor.

  • PDF

A Study on the High Power-Factor AC/DC converter using Resonant Auxiliary Circuit (공진형 보조 회로를 이용한 고역률 AC/DC 컨버터에 관한 연구)

  • Han, Dae-Hee;Kim, Yang;Baek, Soo-Hyun;Bae, Jin-Yang;Kim, Pil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1110-1113
    • /
    • 2002
  • A Single-Stage Single-Switch power-factor- correction(PFC) AC/DC Converter with universal input is presented in this paper. The PFC Converter can be achieved based upon the continuous current mode(CCM). The switch has less current and voltage stresses over a wide range of load variation so that a low voltage rating device can be used. The presented converter features high power factor high efficiency, and low cost. An 90W prototype was implemented to show that it has 70% efficiency with low voltage stress over universal line input.

  • PDF

Real-Time Estimation of the Boost Inductance in a Single-phase AC/DC parallel PWM converter for High-speed EMU (동력분산형 고속철도의 단상 병렬 AC/DC PWM 컨버터를 위한 승압형 인덕턴스의 실시간 추정)

  • Jung, Hwan-Jin;Park, Byoung-Gun;Hyun, Dong-Seok
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.259-264
    • /
    • 2009
  • This paper proposes a real-time estimation of the boost inductance in a single-phase AC/DC parallel PWM converter for high-speed EMU. The estimation procedure of the boost inductance is only based on the variation of input current and the input AC voltage measurement. The estimated boost inductance is optimized by the least square method. This estimation technique can improve the performance of current controller and reduce the harmonics of the input current in the feed-forward controller. The validity of proposed technique is verified through the MATLAB SIMULINK simulation results.

  • PDF