• Title/Summary/Keyword: AC energy

검색결과 1,020건 처리시간 0.027초

The Magnetization Behavior of Amorphous Fe84-zNb7B8+xCu1 (x0, 1, 4) Alloys

  • Kim, Kyeong-Sup;Moon, Young-Mo;Lee, Jae-Bong;Yu, Seong-Cho;Lim, Woo-Young
    • Journal of Magnetics
    • /
    • 제4권1호
    • /
    • pp.10-12
    • /
    • 1999
  • We report the salient features of the magnetic properties of amorphous$ Fe_{84-x}Nb_7B_{8+x}Cu_1$ (x=0, 1, 4) alloys. The study of dc-magnetization properties and the ac-susceptibility was carried out. The temperature dependence of the magnetization follows the predictions of spin wave excitations with long wavelengths. Especially, the addition of boron modifies the magnetic properties: the spin wave stiffness increases from 56.8 to 65.7 meV$\AA$2 and Curie temperature increases from 298 K to 352 K. This result indicates a magnetic hardening of the exchange interaction by higher exchange energy. Thus, the substitution of iron by boron favours the increase of magnetic order in this system.

  • PDF

전류형 인버터를 이용한 계통 연계형 태양광 발전 시스템에 관한 연구 (Study on Grid-Connected Photovoltaic System using Current-Source Inverter)

  • 임정민;박성준;이상훈;문채주;최준호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.677-681
    • /
    • 2005
  • This Paper presents a 6 pulse shift operation control mode of current-source-inverter to make improvement of efficiency and to reduce the frequency of inverter switching for photovoltaic generation system using PWM current-source-inverter. This system is connected solar cell energy directly without using a storage cell. The proposed circuit can maintain maximum voltage of photovoltaic generation of take advantage of six Buck-Boost converter and a full-bridge inverter determines the polarity of AC output. That is controlled by using digital signal processor TMS320F2812 for operation about a 6 pulse shift operation control of current-source-inverter, and it is verified through the experimental results.

  • PDF

실시간 원격 배터리 점검 시스템의 개발 (Development of the Real-Time Remote Battery Inspection System)

  • 이종학;김형원;최우진
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.72-79
    • /
    • 2016
  • Uninterruptible power supplies are extensively used as backup power in various applications such as telecommunication systems, Internet data centers, hospitals, and military technologies. Some of these applications require a considerable number of batteries, and the maintenance of such batteries is critical for the reliability of a system. However, batteries are chemical energy storage devices that deteriorate over time and frequently inspecting their performance and suitability is difficult. A real-time remote battery inspection system that applies electrochemical impedance spectroscopy is proposed and implemented in this study. The proposed system consists of a small inspection circuit and software for control. The former is developed to monitor the impedance variation of the battery and to diagnose its state. The validity and feasibility of the proposed system is proven by experimental results.

Analysis and Design of a New Topology of Soft-Switching Inverters

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.51-58
    • /
    • 2013
  • This paper proposes the power conversion mechanism of a bailer-charge-transfer zero-current-switching (CT-ZCS) circuit. The operation modes are analyzed and researched using state trajectory equations. The topology of CT-ZCS based on soft-switching inverters offers some merits such as: tracking the input reference signal dynamically, bearing load shock and short circuit, multiplying inverter N+1 redundancy parallel, coordinating power balance for easy control, and soft-switching commutation for high efficiency and large capacity. These advantages are distinctive from conventional inverter topologies and are especially demanded in AC drives: new energy generation and grid, distributed generation systems, switching power amplifier, active power filter, and reactive power compensation and so on. Prototype is manufactured and experiment results show the feasibility and dynamic voltage-tracking characteristics of the topology.

빌딩에 적용되는 DC 배전 시스템의 통합 운전 (Integrated Operation of DC Distribution System for Building Application)

  • 한동우;신수철;이희준;원충연;이택기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.57-58
    • /
    • 2013
  • 본 논문에서는 빌딩과 같은 건축물에 적용될 DC 배전 시스템의 통합 운전에 대하여 제안 및 분석을 하였다. 제안하는 DC 배전 시스템은 AC/DC 전력 변환 모듈 2개와 하나의 ESS (Energy Storage System) 모듈이 병렬로 연결 되어있으며, ESS와 부하의 상태에 따라 적합한 운전 모드로 동작 하게 된다. ESS와 부하의 상태는 시뮬레이션을 통해 모의하였으며, 제안된 시스템은 각 상황에 대응하는 제어가 원활히 이루어지는 것을 검증하였다.

  • PDF

Weil-Dobke 합성단락 시험회로의 Parameter 분석과 최적화 (Analysis and optimization of Wiel-Dobke synthetic testing circuit parameters)

  • 김맹현;류형기;박종화;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.623-627
    • /
    • 1995
  • This paper describes analysis and optimization of Weil-Dobke synthetic testing circuit parameters, which is efficient and economical test method in high capacity AC circuit breaker. In this paper, analysis of synthetic short-circuit test circuit parameter proposed nondimensional factor that is reciprocal comparison value of circuit parameter and is not related to rated of circuit breaker, in particular, this study induce minimization of required energy of critical TRV generation specified in IEC 56 standards and present optimal design of synthetic short circuit testing facilities.

  • PDF

높은 선형성을 가진 3 V 10b 영상 신호 처리용 CMOS D/A 변환기 설계 (A Design of a Highly Linear 3 V 10b Video-Speed CMOS D/A Converter)

  • 이성훈;전병렬;윤상원;이승훈
    • 전자공학회논문지C
    • /
    • 제34C권6호
    • /
    • pp.28-36
    • /
    • 1997
  • In this work, a highly linear video-speed CMOS current-mode digital-to-analog converter (DAC) is proposed. A newswitching scheme for the current cell matrix of the DAC simultaneously reduces graded and symmetrical errors to improve integral nonlinearities (INL). The proposed DAC is designed to operate at any supply voltage between 3V and 5V, and minimizes the glitch energy of analog outputs with degliching circuits developed in this work. The prototype dAC was implemented in a LG 0.8um n-well single-poly double-metal CMOS technology. Experimental results show that the differential and integral nonlinearities are less than .+-. LSB and .+-.0.8LSB respectively. The DAC dissipates 75mW at a 3V single power supply and occupies a chip area of 2.4 mm * 2.9mm.

  • PDF

Magnetic Characterization of the Nd Based Permanent Magnet by Newly-Developed Bipolar Pulse-Type Hysteresis Loop Tracer

  • Rhee, J.R.
    • Journal of Magnetics
    • /
    • 제4권3호
    • /
    • pp.73-75
    • /
    • 1999
  • By appliying an slternate pulsed magnetic field -generated by using a sequential ignition circuit and a magnet exciting circuit- with peak value of about 10 T to the rod type Nd based magnet Nd2Fe12.7Cr1.3B with length of 5 mm and diameter of 3.6 mm, the basic magnetic properties such as saturation magnetization, residual magnetization, coercivity, maximum energy products, magnetic anisotropy and anisotropic field are investigated with obtaining the major and minor J-H loops of the magnet. The increase in coercivity due to eddy currents in ac measurement of coercivity is calculated considering eddy current loss by analyzing a wave of generating magnetic field. The average coercivity calculated for the magnet is about 12.2 kOe, anisotropy magnetic field and anisotropic constant are measured as 60 kOe 2.43 Mj/$m^3$, respectively.

  • PDF

PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구 (A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization)

  • 안종보;김원곤;황기현;박준호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

3상 계통연계 태양광발전시스템의 운전특성 (Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System)

  • 김영철;정명웅;서기영;이현우;우준인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF