• Title/Summary/Keyword: AC energy

Search Result 1,024, Processing Time 0.036 seconds

Influence of Silicon and Seed Particles on the Reconstruction Characteristics and Exaggerated Grain Growth of MgO Protective Layer by Over-Frequency Accelerated Discharge in ACPDPs

  • Kwon, Sang-Koo;Kim, Jeong-Ho;Moon, Seung-Kyu;Choi, Jong-Kwon;Park, Kyu-Ho;Han, Sung-Su
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.957-960
    • /
    • 2008
  • The influences of silicon and MgO seed particle on the reconstruction characteristics of MgO protective layer were investigated to clarify the mechanism of reconstruction and exaggerated grain growth (EGG) in AC-PDP. The reconstruction and EGG are closely correlated with the driving force for nucleation and growth, interface energy and initial size distribution of MgO protective layer in plasma space during discharge in AC-PDP.

  • PDF

Influence of sintering temperature of MgO pellet on the electro-optical characteristics of alternating current plasma display panel (AC-PDP)

  • Hong, Sung-Hee;Son, Chang-Gil;Jung, Seok;Kim, Jung-Seok;Paik, Jong-Hoo;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.400-403
    • /
    • 2008
  • We have investigated the electro-optical characteristics of AC-PDP with different MgO protective layers, which have been deposited by electron beam evaporation from various sintered pellets with different temperatures. We have measured the secondary electron emission coefficient ($\gamma$) by using the Gamma Focused Ion Beam ($\gamma$-FIB) system, the static margin, and the address delay time. Also, we have investigated photoluminescence (PL) characteristics for understanding the energy levels of MgO pellets and protective layers.

  • PDF

Photon-induced surface conductivity measurement of MgO in an AC PDP

  • Ha, Chang-Hoon;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.130-133
    • /
    • 2006
  • In order to study the relationship between the discharge characteristics of an ac PDP and the surface conductivity of MgO thin film, the surface current across a ring shaped MgO film was measured by exposure to monochromatic vacuum ultraviolet from the synchrotron radiation source whose wavelength ranges from 60nm to 240nm $(5.5eV{\sim}25eV)$. The experimental results show that the surface current begins to increase rapidly at the photon energy of about 9 eV which might correspond to the valence band edge of MgO. The difference in the surface current level correlate well with the differences in the preparation method of MgO films and their respective discharge characteristics such as the firing, minimum sustain voltages, address voltage margin and address discharge delay time.

  • PDF

Electro-Optical characteristics with dielectric thickness of AC-PDP

  • Jung, K.B.;Choi, J.H.;Kim, S.B.;Jung, Y.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.768-770
    • /
    • 2003
  • In AC PDP, since charges generated by gas discharge are accumulated on the dielectric. The dielectric is a major factor to determine cell capacitance and its memory effect is a play an important role in PDP driving. In this experiment, we have investigated the electro-optical characteristics with dielectric thickness and we have analyzed wall charge and wall voltage by Q-V energy diagram. The dielectric thickness was varied from 20 um to 50 um. As results, according to the dielectric thickness increase,cell capacitance and power consumption is reduced.

  • PDF

Loss Cut of Air-Cooled Waterwheel Generator with AC Variatle Speed Drive for Cooling Fan Motor(s) (교류 가변속 장치의 냉각팬 적용에 의한 수력 발전기 손실 저감)

  • Hur, Sung-Kwang;Rhew, Hong-Woo;Park, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.579-582
    • /
    • 1989
  • The air-cooled waterwheel generator has a fan connected to waterwheel shaft or motor driven fan or fans. The fans are operated at constant speed, constant input, regardless of generator loss which is varied according to generator output and coolant the perature. Energy savings may he possible if the cooling air flow is controlled according to generato output and air temperature depending on season. The simulation and experience have been done on the 22.6 KVA Waterwheel generator by using AC variable speed drive. The results gave us los cut of generator.

  • PDF

A Study on the Separation Distance to Protection of Buried Pipeline from Arc Strikes Caused by Power Line Ground Fault Current (지락사고시 지중금속배관에 대한 아크이격거리에 관한 연구)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Kim, Suk-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.154-155
    • /
    • 2002
  • The demand of the power and gas energy have been rapidly increasing with the industralization, therefore, the area where buried pipelines run parallel with the adjacent power lines and cross them increases in Seoul as well as other cities. These situation cause AC interference from the power lines. However, there aren't any standards to preserve the pipelines from AC interference in Korea. This study introduces the separation distance to protection of buried pipeline from arc strikes caused by power line ground fault current. And this study examines and compares the arc distance through case study.

  • PDF

A Study on the Motor Control System Driven by Battery (배터리 구동 모터제어시스템에 관한 연구)

  • 김홍건;강영우;유기현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.195-200
    • /
    • 2003
  • An electric vehicle uses the system to a power source whether it limps a high efficiency, without environmental pollution It coincides the best at the 21th century environmental regulation and energy frugality. The motor control system using DC-DC converter is carried out in this study. The Present control system is structured the better condition than that of the AC-DC converter with DC-AC inverter. Further, a vehicle dynamics analysis is peformed for the case of Mini-Baja it is found that the analysis dynamic system for the Mini-Baja gives a good design parameters.

  • PDF

Optimal Inductance of Three-phase High-Power Factor Converter (3상 고역률 AC/DC 컨버터의 부하에 따른 최적 인덕터값)

  • Chun, J.H.;Kim, C.S.;Bark, J.M.;Lee, S.H.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.246-249
    • /
    • 1995
  • This paper proposed a partial resonant swtiching three-phase high power factor converter using a lossless snubber. The proposed converter has a merit of simple controlled circuit because tile input current control discontinuously. And it is improve to input power factor that the snubber capacitor's energy regenerate to the AC source side. This topology is reduced a current/voltage stresses of resonant devices in addition to a partial resonant strategy. The result of simulations with the proposed topology included in this paper.

  • PDF

Stability of Solar Power System on the Control Modes of a Forced-Commutated Inverter and a Line-Commutated Inverter (Solar Power System의 인버터 토폴로지 및 제어 모드에 따른 안정도 연구)

  • Lee, Seung-Hyun;Chung, Gyo-Bum;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.534-537
    • /
    • 1997
  • Solar power systems have become popular in the modem electric energy system. In order to supply the DC power, generated by solar cells, to the electric power system, the solar power system requires DC-to-AC power conversion. A line-commutated inverter or a forced-commutated inverter can be used in the DC-to-AC power conversion. Because of the nonlinear V-I characteristics of the solar cells, multiple operating points determined by the control mode of the inverter exist in the DC V-I state plane of the solar power system. In this paper, the stability of utility-interactive solar power system with a line-commutated inverter is analyzed at various operating points, using the eigenvalue method and the state-plane analysis technique. The stability of a forced-commutated inverter case is also anaiyzed and compared to that of the line-commutated inverter case.

  • PDF

Power Factor Correction of the Single-State AC/DC Converter with Low conduction Loss and High Efficiency

  • Ryu, Myung-Hyo;Choi, Byungcho;Kim, Heung-Geun;Cha, Young-Kil
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.281-286
    • /
    • 1998
  • This paper proposes a new single-stage, single-switch AC/DC converter based on the boost power factor correction (PFC) cell. The converter offers both high power factor and high efficiency. To reduce the dc voltage on the energy storage capacitor, the dc bus voltage feedback method was used. A 100W (5V/20A) prototype was built and tested to show the validity of the proposed converter.

  • PDF