• 제목/요약/키워드: AC electric vehicle

검색결과 78건 처리시간 0.03초

전철 탑재용 피뢰기의 설계 및 성능평가 (Design and Performance Evaluation of Surge Arrester for Loading in Railway Rolling Stock)

  • 조한구;한세원;이운용;김석수;장태봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.74-77
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock. pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

DC 3000V용 보조전원장치 개발 (The Development of APU(Auxiliary Power Supply Unit) for DC 3000V)

  • 김진용;김연충;한정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1654-1660
    • /
    • 2011
  • The korea Electric Railway feeder voltage is DC 1500V and AC 250000V. The auxiliary power supply of the vehicle auxiliary power units for domestic electrical feed has been developed with domestic technology hyeonchae mounted station, and domestic uses, such as voltage, have been exported to other countries. However, do not use at domestic that can be used for DC 3000V voltage auxiliary power unit does not develop, vehicle exports global. This has already been replaced by imported products from other nations is a real situation. Thus, our auxiliary power unit for the DC 3000V was developed, it will be exported to Ukraine. In this paper, We introduced circuit and structure of developed auxiliary power supply unit, and verified the performance with output characteristic of the auxiliary power unit.

  • PDF

전동차 브레이크 스퀼 소음 현상에 대한 연구 (Study on the phenomena of brake squeal noise in rail vehicle)

  • 양용준;김성걸;박영일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.405-410
    • /
    • 2004
  • There are two types of noises in running the rail vehicle. The one is periodic by electric motors, dehumidifiers, and dusting machines. And the other is aperiodic squeal noise by the frictions between the wheels and the rail or the disks and pads. The periodic noises in rail vehicle have been reduced by changing DC motors to AC motors with silencers, and by improving the lubricants. However, almost nothing relating a periodic noise has been studied. In this paper, the experimental methods were applied to understand phenomena of the squeal noise, which was occurred by the friction variation due to aperiodic stick and slip with low repeatability in the process of dry friction of the disk and the pad when a rail vehicle was being braked. By the experimental acoustic test, it was found the specific frequencies relating the squeal noise. And by modal testing, it was measured the resonant frequencies in the disk and the pad-plate which were the components of the braking system, and in the whole braking system, and it was found the specific frequencies having the effects on the squeal noise.

  • PDF

EMTP를 이용한 전기자동차용 급속 충전시스템 모델링 (The Modeling of EV Fast Charging System using EMTP)

  • 주성철;심형욱;이제원;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.203-204
    • /
    • 2011
  • There is a growing interest on Electric Vehicles due to global warming and greenhouse gas emission issue. Recently, new technologies of EV fast charging are continually being developed and power supply infrastructure technologies are being developed widely. In general, the fast charging system consists of AC-DC converter, DC-DC converter, and filters. This paper performs modeling of Electric Vehicle fast charging system using EMTP(Electromagnetic transient program).

  • PDF

An Effective Control Scheme for Battery Charger System in Electric Vehicles

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.232-233
    • /
    • 2012
  • This paper presents an effective control scheme for an electric vehicle battery charger where a symmetrical bridgeless power factor-corrected converter and a buck converter are cascaded. Both converters have been popular in industries because of their high efficiency, low cost, and compact size, hence combining these converters makes the overall battery charging system strongly efficient. Moreover, this charger topology can operate at universal input voltage and attain a desired battery current and voltage without ripple. In order to achieve a unity input power factor and zero input current harmonic distortion, the proposed control scheme adopts duty ratio feed-forward control technique in both current and voltage control loop. Additionally, in the current loop, its reference is created by a phase-locked loop (PLL) block, leading to a pure sinusoidal input current although the input voltage waveform is being distorted. The feasibility and practical value of the proposed approach are verified by simulation and experiment with an 110V/60Hz ac line input and 1.5kW-72V dc output of the battery charging system.

  • PDF

주회로차단기 투입전원 위상제어를 위한 지능형 제어기 개발 (A Development of Intelligent Controller for Phase Control in Main Circuit Breaker)

  • 오용국;김재원;류준형
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.755-761
    • /
    • 2017
  • 교류 철도차량에 사용되는 주회로차단기 (Main Circuit Breaker)는 전차선 전원을 차량 내 투입 또는 차단하는 기능을 한다. 일반적으로 주회로차단기는 판토그라프와 주변압기 사이에 위치하며, 주회로차단기의 동작시점에 따라 차량에 투입되는 전원의 위상이 변화하게 된다. 투입전원의 위상에 따라 차량 내 돌입전류, 서지전압 등의 형태로 차량 전기장치 내 의도하지 않은 과도현상이 야기될 수 있으므로, 주회로차단기의 동작은 전차선 전원의 위상각에 따라 능동적으로 제어되어야 한다. 하지만 주회로차단기는 동작신호 인가 이후, 실제 개폐 동작 시까지 일정하지 않은 동작지연시간이 존재한다. 따라서 동작 지연시간을 예측하고, 이를 고려하여 주회로차단기를 개폐시점을 제어하는 지능형 제어기가 필요하다. 본 논문에서는 주회로차단기의 투입전원 위상 제어를 위하여 동작 메카니즘 및 동작 지연요소를 분석하였다. 그리고 차단기 및 구성품 별 반복동작시험을 통하여 동작 지연시간을 분석하고, 이를 예측하기 위한 이동평균 (Moving Average) 알고리즘을 제안하였다. 또한 지능형 제어기 개발 및 제작을 통하여 제안된 알고리즘을 구현하였으며, 주회로차단기와의 연동시험을 통하여 알고리즘의 성능을 검증하였다.

V2G-V2H 기능을 갖는 3.3kW급 전기자동차용 양방향 충전기 (A 3.3kW Bi-directional EV Charger with V2G and V2H function)

  • 정세형;홍석용;박준성;최세완
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.31-37
    • /
    • 2015
  • This paper proposes a 3.3-kW bi-directional EV charger with V2G and V2H functions. The bi-directional EV charger consists of a DC-DC converter and a DC-AC inverter. The proposed EV charger is suitable for wide battery voltage control due to the two-stage configuration of the DC-DC converter. By employing a fixed-frequency series loaded resonant converter as the isolated DC-DC converter, zero-current-switching can be achieved regardless of battery voltage variation, load variation, and power flow. A 3.3-kW prototype of the proposed EV charger has been built and verified with experiments, and indicates a maximum efficiency of 94.39% and rated efficiency of 94.23%.

Wireless Power Transfer for Electric Vehicles Charging Based on Hybrid Topology Switching With a Single Inverter

  • Chen, Yafei;Zhang, Hailong;Kim, Dong-Hee;Park, Sung-Jun;Park, Seong-Mi
    • 한국산업융합학회 논문집
    • /
    • 제23권2_1호
    • /
    • pp.115-124
    • /
    • 2020
  • In wireless power transfer (WPT) system, the conventional compensation topologies only can provide a constant current (CC) or constant voltage (CV) output under their resonant conditions. It is difficult to meet the CC and CV hybrid charging requirements without any other schemes. In this study, a switching hybrid topology (SHT) is proposed for CC and CV electric vehicle (EV) battery charging. By utilizing an additional capacitor and two AC switches (ACSs), a double-side LCC (DS-LCC) and an inductor and double capacitors-series (LCC-S) topologies are combined. According to the specified CC and CV charging profile, the CC and CV charging modes can be flexibly converted by the two additional ACSs. In addition, zero phase angle (ZPA) also can be achieved in both charging modes. In this method, because the operating frequency is fixed, without using PWM control, and only a small number of devices are added, it has the benefits of low-cost, easy-controllability and high efficiency. A 3.3-kW experimental prototype is configured to verify the proposed switching hybrid charger. The maximum DC efficiencies (at 3.3-kW) of the proposed SHT is 92.58%.

PAV 케이블 하네스에 대한 낙뢰 간접 영향성 인증 기법에 관한 연구 (A Study of Certification of Lightning Indirect Effects on Cable Harness in Personal Air Vehicles)

  • 조재현;김윤곤;박세웅;명노신
    • 한국항공우주학회지
    • /
    • 제49권3호
    • /
    • pp.251-262
    • /
    • 2021
  • 최근 세계적으로 연구개발이 활발히 진행되고 있는 PAV(Personal Air Vehicle)에 대한 낙뢰 간접 영향성 인증 지침의 중요성이 부각되고 있다. 미래 교통수단으로서 소형화, 전기 엔진 사용, 복합재 사용 증가, 무인 항법 시스템 적용하는 추세인 PAV는 낙뢰에 취약할 수밖에 없다. 본 연구에서는 미연방항공청(FAA)에서 발행한 AC 20 136B에 나타난 낙뢰 간접 영향에 대한 적합성 인증절차를 확인하였다. 이와 함께 RTCA DO 160G Sec. 22에 수록된 장비 과도 설계 수준에 대한 인증 지침을 PAV에 적용하였다. 이어서 SAE ARP 5416A에 수록된 항공기 수준 시험을 전자기 해석 소프트웨어 EMA3D을 통해 수행하였다. 이를 통해 PAV에 대한 실제 과도 수준을 분석하였으며 이를 통해 적합성 인증에 필요한 자료를 도출하였다.

AT 급전계통 고장 모의시험장치를 활용한 임피던스 계전방식의 성능검증 (Performance verification on the Impedance Relay Method using Failure Simulator of AT Feeding System)

  • 김완일;이계승;정노건;김재문
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.325-330
    • /
    • 2018
  • In this paper, we investigated the impedance method for searching fault detection point in case of an accident in the AC electric railway AT feeding system. For this purpose, simulation circuit modeling and prototype hardware are made based on the known numerical analysis. As a result of simulation modeling of the feeding system based on the numerical analysis of the impedance method confirmed that the modeling was properly implemented with an average error rate of 0.07%. Also, as a result of fault event by hardware simulator, it was confirmed that the breaker operation time is shortened and the fault current is decreased while the voltage is close to the supply voltage in the transient state as the point of the fault accident moves away from the substation(SS).