• Title/Summary/Keyword: AC electric field

Search Result 268, Processing Time 0.032 seconds

AC Breakdown Analysis by Epoxy Thickness in Composite-Insulation (복합절연물내의 에폭시 두께에 따른 AC 절연파괴 분석)

  • Jung, Hae-Eun;Yun, Jae-Hun;Kim, Byoung-Chul;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.468-469
    • /
    • 2007
  • $SF_6$ gas used widely as insulating component in electric power industry has excellent in insulation and arc extinguishing performance in gas-insulated switchgear. However, the concern about eco-friendly alternative gas is currently rising, because $SF_6$ gas is one of the main greenhouse gases. As one of the study for $SF_6$ free technology, composite-insulation technology is focused in this paper. To analyze the influence by epoxy thickness change, the composite-insulation composed of dry-air and epoxy was used in this paper. To analyze AC breakdown by the epoxy thickness, needle-plane electrode was used and needle was molded by epoxy. Under the gas pressure ranged from 0.1 to 0.6MPa, the breakdown voltage of dry-air were measured in AC electric field. The data of composite-insulation were acquired by changing the thickness of epoxy used in each composite-insulation under the same condition.

  • PDF

Effect of Magnetic Field on NOx Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOx 제거에 미치는 자계의 영향)

  • Park, J.Y.;Son, S.D.;Han, S.B.;Lee, D.H.;Kim, J.D.;Mun, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2251-2252
    • /
    • 1999
  • In this paper, the effect of magnetic field was measured on NOx removal characteristics for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx from simulated diesel engine flue gas are decomposed by the corona discharge of DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power decreased. NOx removal rate and arc transition voltage of plasma reactor with magnetic field were higher than those of plasma reactor without magnetic field.

  • PDF

Analysis and measurement of low frequency magnetic field according to internal position of electric railway train (전기철도차량 객실 내부 위치에 따른 극저주파 자계 측정 및 분석)

  • Jang, Dong-Uk;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.489-494
    • /
    • 2008
  • The measurement of magnetic field is performed about DC and AC magnetic field in electric railway line. The test point is cap, on the converter/inverter box, on the traction motor and on the SIV, the height of measurement is bottom and 60 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through BNC output, DAQ cad and notebook PC.

  • PDF

Comparision Study Between Modeling and Experiment of the Breakdown Voltage for AC Plasma Display Panel (AC 플라즈마 디스플레이패널의 방전개시전압에 모델과 실험의 비교에 관한 연구)

  • 박장식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1039-1044
    • /
    • 2000
  • Breakdown voltage model and expertiments are compared for discharge cells of AC plasma display panel. In the model, discharge paths are assumed to be initial electric field lines and the one-dimensional continuity equation is applied to the charged particle transport at each field line. The comparisons are performed in the wide range of gas pressure (50-600torr), Xe partial pressure over total pressure (1-6%), sustain electrode gap(100-1000$\mu\textrm{m}$), wall height(130, 300$\mu\textrm{m}$), and voltage pulse width(2-6${\mu}$s). The presented breakdown voltage model well agree with experiments in the above wide range. The increase of breakdown voltage with the decrease of the width(L) of protruding electrode is also described by the model.

  • PDF

Behavior of Water Droplet on the Polymer Surface and Influence of the Charge

  • Zhu, Yong;Yamashita, Seiji;Anami, Naoya;Otsubo, Masahisa;Honda, Chikahisa;Takenouchi, Osamu;Hashimoto, Yousuke
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.81-85
    • /
    • 2003
  • This paper describes the results of experiments made to examine the behavior of water droplet on the polymer surface and influence of the charge. In this experiment, water droplet was put on the polymer surface in an applied AC electric field and the investigations of its behavior were done with a high-speed video camera. It can be observed that the droplet elongates and vibrates with being pulled towards the positive electrode in a wave synchronism with the frequency of the power source. The volume and conductivity of water droplet are shown to have a marked effect on the mode of discharge development. These behaviors may be caused by the change of electric field of applied AC voltage and induced charges in/on the water droplet.

Application of a Robust Fuzzy Sliding Mode Controller Synthesis on a Buck-Boost DC-DC Converter Power Supply for an Electric Vehicle Propulsion System

  • Allaoua, Boumediene;Laoufi, Abdellah
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.67-75
    • /
    • 2011
  • The development of electric vehicle power electronics system control, composed of DC-AC inverters and DC-DC converters, attract much research interest in the modern industry. A DC-AC inverter supplies the high-power motor torques of the propulsion system and utility loads of electric vehicles, whereas a DC-DC converter supplies the conventional low-power and low-voltage loads. However, the need for high-power bidirectional DC-DC converters in future electric vehicles has led to the development of many new topologies of DC-DC converters. The nonlinear control of power converters is an active research area in the field of power electronics. This paper focuses on the use of the fuzzy sliding mode strategy as a control strategy for buck-boost DC-DC converter power supplies in electric vehicles. The proposed fuzzy controller specifies changes in control signals based on the surface and knowledge on surface changes to satisfy the sliding mode stability and attraction conditions. The performance of the proposed fuzzy sliding controller is compared to that of the classical sliding mode controller. The satisfactory simulation results show the efficiency of the proposed control law, which reduces the chattering phenomenon. Moreover, the obtained results prove the robustness of the proposed control law against variations in load resistance and input voltage in the studied converter.

A Development of Reduced-scale Model to Predict of Environmental Characteristics of AC/DC Hybrid Overhead Transmission Line (AC/DC 하이브리드 선로의 전기환경특성 예측을 위한 축소모델 개발)

  • Choi, In-Hyuk;Shin, Koo-Yong;Lee, Dong-Il;Lim, Jae-Seop;Kim, Young-Hong;Maeng, Jong-Ho;Ju, Mun-No
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.676-682
    • /
    • 2012
  • To review application of HVDC (High Voltage Direct Current) transmission line to HVAC T/L in operation, reduced-scale model was designed and manufactured. The arms of model were designed to change height and interval of conductors. Electrical environmental interferences were estimated by various configuration of AC 345kV and DC 250kV T/L. The interferences such as electric field intensity and ion current density were measured and converted reduced-scale factor to full-scaled. Additionally, effects between AC and DC T/L were studied.

Effect of Magnetic Field on NOX Removal for Wire-Plate Plasma Reactor (선대 평판형 플라즈마 반응기에서 NOX 제거에 미치는 자계의 영향)

  • Park, Jae-Yun;Go, Hui-Seok;Son, Seong-Do;Lee, Dong-Hun;Kim, Jong-Dal
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.2
    • /
    • pp.120-124
    • /
    • 2000
  • In this paper, the effect of magnetic field was measured on NOx(NO+NO2) removal and consumption power for wire-plate plasma reactor with magnetic field applied to electric field vertically. NOx of the simulated diesel engine flue gas were removed by the corona discharge generated by DC, AC and Pulsed voltages in wire-plate reactor. Consumption power increased with discharge voltage. However, when magnetic field was applied to electric field vertically, consumption power slightly decreased. NOx removal rate and arc transition voltage for plasma reactor with magnetic field were higher than those for plasma reactor without magnetic field. Consumption power decreased, however NOx removal significantly increased, when water vapour bubbled by dry air was put into simulated flue gas.

  • PDF

Development of an Inspection System of Contact Light Emitting Device for Quality Control

  • Lee, Jun-Ho;Kwon, Hyung-Kee;Ryu, Young-Kee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.118.3-118
    • /
    • 2001
  • CLED (Contact Light Emitting Device) has three layers consisting of a transparent electrode, a light emitting layer and a substrate. When the substrate of the CLED comes in contact with a fingerprint under AC input voltage, it makes an electric field between the fingerprint and the device. Due to the electric field, the light is emitted along the ridgeline of the fingerprint. The intensity along the ridge on the surface of the CLED increase in proportion to the electric field. To achieve uniform performance of fingerprint verification devices, inspection system of CLED for quality control were required. In this research, we proposed the factors for quality controls such as dimensions of the CLED, uniformity ...

  • PDF

Electrically controllable polymer-dispersed liquid crystal (전기적 스위칭이 가능한 고분자 분산형 액정 제작 및 동적 홀로그램 기록 특성)

  • 성기영;경천수;이영락;최병철;곽종훈;최옥식;이윤우
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.494-499
    • /
    • 1999
  • We report on the results of holographic transmission grating that can be controlled by the applied AC electric field. We have fabricated a polymer-dispersed liquid crystal material that composed of multifunctional acrylate monomer blended with the liquid crystal mixture E7. To investigate an electro-optic properties of fabricated HPDLC, diffraction efficienties (DE) are measured as a fuction of applied electric field and density of liquid crystal. Maximum DE of about 70% is obtained about 30 wt% of LC concentration at a zero field. We have also shown that optical image was recorded in the tllm, and then the reconstructive image was switchable with the applied electric fields. ields.

  • PDF