• 제목/요약/키워드: AC electric field

검색결과 268건 처리시간 0.027초

Effect of Amino Silane Coupling Agent on the AC Electrical Breakdown Phenomena of Epoxy/Layered Silicate Nanocomposite in Needle-plate Electrodes

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권3호
    • /
    • pp.149-152
    • /
    • 2012
  • The effects of amino silane coupling agent on the AC electrical treeing and breakdown behaviors in an epoxy/layered silicate (1 wt%) were examined in needle-plate electrode geometry. A layered silicate was exfoliated in an epoxy base resin by using our AC electric field apparatus. To measure the tree initiation and propagation and the breakdown rate, an alternating current (AC) of 10 kV (60 Hz) was applied to the specimen in needle-plate electrode arrangement with a $30^{\circ}C$ insulating oil bath. In the epoxy/amino silane system, the tree initiation time was 11.5 times higher and the breakdown time was 17.9 times higher than those of the neat epoxy resin. The tree initiation time in the epoxy/layered silicate (1 wt%) system with the amino silane was 2.0 times higher, and the breakdown time was 1.5 times higher than those of the epoxy/layered silicate (1 wt%) system.

유전이동을 이용한 콜로이드 입자의 크기에 따른 분리 (The Separation of Colloid Particles of Different Sizes by Dielectrophoresis)

  • 황연
    • 한국재료학회지
    • /
    • 제17권3호
    • /
    • pp.167-172
    • /
    • 2007
  • The separation of the small colloidal particles from the mixture of two different sized particles using AC dielectrophoresis phenomenon was studied. The spherical mono-dispersed polystyrene particles dispersed in pure water were put into a perfusion chamber on a substrate, and AC electric fold was applied to the glass substrate with Au electrodes in 4 mm distance. The AC frequency was fixed at 1 kHz and the intensity of the field was varied from 25 V/cm to 160 V/cm. After applying the AC field, the degree of the chain formation that resulted from the particle movements by dielectrophoresis was observed by optical microscope. The mixture of the $1\;{\mu}m\;and\;5\;{\mu}m$ sized polystyrene particles at 0.5 vol% concentrations for each size was set in the dielectrophoresis conditions of 1 kHz and 100 V/cm. At this condition large $5\;{\mu}m$ sized polystyrene particles formed chains, on the contrary the $1\;{\mu}m$ sized polystyrene particles formed no chains. After water flowing for 20 min, it was found that small particles that were floating in the chamber had been removed by the water flowing.

Development of High Efficiency PDP Driven by RF Pulses

  • Choi, J.P.;Jeon, W.G.;Kang, J.;Lim, G.S.;Kim, O.D.;Kim, H.Y.;Song, J.W.;Yoo, E.H.;Park, M.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.169-170
    • /
    • 2000
  • The conventional AC PDP has a relatively low efficiency which is close to 1.5 lm/W. If the AC sustain period is replaced by the RF sustain period, due to oscillating and low electric field, almost 60% of the supplied energy is spent by Xe excitation [1]. The efficiency of RF PDP can be $4{\sim}5$ times higher than that of AC PDP. In this paper, we will present the RF PDP that is a new type of PDP. A new display method in PDP using RF pulses is suggested and applied on a 4-inch-diagonal Panel (hereinafter 4" panel). Even though there were many researches in RF discharge, there was not enough research for display application. Now we propose the RF PDP that is a new display field and we will expect to do more research in this field.

  • PDF

저밀도 폴리에틸렌의 고전계 파형에 대한 필름 두께 의존성 (Film Thickness Dependence of Ac High Field for Low Density Polyethylene)

  • 최용성;위성동;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.45-49
    • /
    • 2008
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

Influence of Electrical Aging on Space Charge Dynamics of Oil-Impregnated Paper Insulation under AC-DC Combined Voltages

  • Wang, Yan;Li, Jian;Wu, Sicheng;Sun, Peng
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1512-1519
    • /
    • 2013
  • Oil-impregnated paper is a major type of insulation used in oil-filled converter transformers for both traditional and new energy systems. This paper presents and analyzes the results of the experiment conducted on the electrical aging of oil-impregnated paper under AC-DC combined voltages using the pulsed electro-acoustic (PEA) technique. The formation and dynamics of space charge affected the performance of insulation material. The electrical aged oil-paper insulation was obtained through electrical aged experiments under the voltages. Based on the PEA technique, measurements were carried out when the oil-paper insulation system was subjected to different stressing and aging times. The space charge dynamics in the bulk of the oil-paper insulation system with different aging times were measured and analyzed. Characteristic parameters such as the total charge injection amount, the total charges of fast moving and slow moving, and the distortion factor of electric field were calculated and discussed. Results show that the longer electrical aging time, the more charges trapped in the bulk of aging sample. It leads to larger distortion factor of electric field in the bulk of aging samples and accelerate degradation of oil-paper insulation under AC-DC combined voltages.

고압전동기 고정자 권선의 온도변화에 따른 절연특성 분석 (Analysis of the Temperature Influence on Insulation Characteristics in High Voltage Motor Stator Windings)

  • 공태식;주영호;김희동;박태성
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.786-790
    • /
    • 2012
  • A variety of diagnostic tests are widely applied in the field in industry to evaluate the condition of high voltage (HV) motor stator insulation. In this paper, the influence of temperature on the stator insulation diagnostic tests such as the insulation resistance, AC current, dissipation factor, and partial discharge measurements are studied and reported. The tests are performed with the HV motor stator winding temperature set between $40^{\circ}C$ to $80^{\circ}C$ in $10^{\circ}C$ intervals. It is shown that the AC current, dissipation factor, and partial discharge magnitude steadily increase with temperature, which suggests that temperature must be taken into account in the interpretation of the test results.

전기철도의 교류 급전변전소에서 PSIM을 이용한 스코트변압기 모델링 (Scott Transformer Modeling using PSIM on the AC Substation in the Elect ric Railroad)

  • 김성대;최규형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1892-1897
    • /
    • 2010
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. PSIM(Power Electronics Simulator) is optimal simulation software in field of the power electronics and provide the simple and convenient user interface. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using PSIM.

  • PDF