• Title/Summary/Keyword: AC distribution

Search Result 566, Processing Time 0.029 seconds

Watt-Hour Metering Characteristics at Scott Transformer in AC Electric Railway Systems

  • Lee, Hansang;Lee, Kyebyung;Kim, Kisuk;Park, Yong-Up;Jeon, Young-Soo;Joo, Sung-Kwan;Jang, Gilsoo;Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1398-1406
    • /
    • 2018
  • Owing to the consistent increase in accurate analysis issue for energy consumption of the AC electric railway systems, there is controversy about the adequacy of the present watt-hour metering configuration. Due to the unusual load characteristics and facilities, the discussions have not been active. Therefore, in order to achieve more accurate watt-hour metering for AC electric railway system, this paper proposes numerical formulas for watt-hour metering that reflects the highly-varying characteristics of the railway load and the structural characteristics of the Scott transformer. The proposed formulas have been verified by comparison with site-measured data, and a more suitable metering configuration for AC railway system has been proposed.

Experimental Study on Electrical Agglomeration of Liquid Particles in an Alternating Electric Field (AC 전기장내 하전 액체 입자의 응집에 관한 실험적 연구)

  • Ji, Jun-Ho;Hwang, Jung-Ho;Bae, Gwi-Nam;Kim, Yong-Gin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.442-450
    • /
    • 2001
  • Experiments were carried out on agglomeration of bipolarly charged particles in an alternating current electric field. Laboratory-scale setup was built and experiments were conducted at atmospheric condition. DOS(Di-octyl Sebacate) particles with 100% purity were generated by an atomizer. The particles were branched into two, each of which passed through a wire-to-plate type charging section where a positive or a negative DC high voltage was applied and was charged positively or negatively. These bipolarly charged particles together passed through an agglomeration section where an $\pm$20kV AC power was applied between two plates. The resident time in the agglomeration section was adjusted as l sec. Particle sampling was made by a cascade impactor (MOUDI). The effect of agglomeration system on the reduction ratio of particles below l ㎛ was 42∼45%. Effect of AC frequency on the particle size distribution was found insignificant.

System Performance with Variation of Outdoor Unit Layouts at Building Re-entrants

  • Koh, Jae-Yoon;Lee, Hyun-Gu;Zhai, John
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • Air-cooled split-type air conditioners (AC) are very popular in high-rise residential and commercial buildings in Korea. The performance of such AC systems varies significantly with system characteristics and environmental conditions. Particularly, the outdoor condensing unit of the system, if poorly cooled due to high density of AC distribution and restricted outdoor space, will result in large decrease of cooling efficiency and increase of electrical energy consumption and may further jeopardize the system reliability. This paper presents a numerical analysis on the thermal and energy performance of a group of air-cooled air conditioners installed at a courtyard of a high-rise building. The study introduces a series of new energy performance indices to assess the group performance of the AC condensers with different outdoor unit layouts. The results not only indicate the COP of the systems, but also quantify the system capacity and energy consumption. The evaluation method and indices developed are useful for guiding the design of the distribution plan of the AC units at building re-entrants.

Integrated Operation of Power Conversion Module for DC Distribution System (직류 배전 시스템을 위한 전력 변환 모듈의 통합 운전)

  • Lee, Hee-Jun;Shin, Soo-Choel;Hong, Suk-Jin;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.240-248
    • /
    • 2014
  • It is DC power that Output of renewable energy being recently developed and researched. Also, demand of DC power will expect to proliferate due to increase of digital load. Thus, DC distribution system providing high quality of power and reliability has emerged as a new distribution system. If the conventional distribution systems are substituted by proposed DC distribution system, the output of renewable energy can be connected with distribution systems under minimum power conversion. Therefore, in the event of connection with DC load, it can construct an efficient distribution system. In this paper, the integrated parallel operation of power conversion module for DC distribution system is proposed. Also, this paper proposed modularization of power conversion devices for DC distribution system and power control for parallel operation of large capacity system. DC distribution system consists of three power conversion modules such as AC/DC power conversion module 2 set, ESS module 1 set. DC distribution system controls suitable operation depending on the status of the DC power distribution system and load. Integrated operation of these systems is verified by simulation and experiment results.

Experiment on DC Circuit Breaker for Inductive Load by Improved Magnetic Arc-extinguisher and Arc-Attenuation Circuit (개선된 자기소호회로와 아크전압 억제회로를 사용한 유도성 부하의 직류차단 특성 실험)

  • Lee, Sung-Min;Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.495-499
    • /
    • 2012
  • Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000. DC distribution systems are also accelerated by the expansion of renewable power systems since they are easy to be interfaced with DC grids rather than AC grids. However, removing the fault current in DC grids is comparably difficult since the current in DC grids has non zero-crossing point like in AC grids. Thus, developing dedicated DC circuit breakers for DC grids is necessary to get safety for human and electrical facilities. Magnet arc extinguishing method is proper to small size DC circuit breakers. However, simple Magnet arc extinguishing method is not enough to break inductive fault currents. This paper proposed a novel DC circuit breaker against inductive fault current defined by IEEE C37.14-2004 Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures. The performance of the proposed DC circuit breaker was verified by an experimental circuit breaker test system built in this research.

Determination of the Size Distribution of Magnetite Nanoparticles from Magnetic Measurements

  • Yoon, Sung-Hyun
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.368-373
    • /
    • 2011
  • Particle size distributions in 10 nm magnetite ferrofluids are analyzed based on both dc and ac magnetic measurements. Modified log-normal distributions are used for fitting the experimental results, which allows for a proper account of the narrow distributions. The calculated average particle sizes are in good agreement with the TEM results. However the ac method gives a much narrower distribution width than that of the dc magnetization curve fit. The proposed measurements combined with the analysis methods are useful for the characterization of ferrofluids being considered for biomedical applications.

Design and Characteristic of the AC Solenoid Valve (AC 솔레노이드 밸브의 설계 및 특성)

  • Kim, Dong-Soo;Jeon, Yong-Sik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3056-3061
    • /
    • 2007
  • The technology of AC solenoid valves is now considered as a core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for medical applications. And AC solenoid valves, which operate by compressed air, are characterized by high speed response, great repeatability and that the pressure on the cross sectional area of poppet is kept constant regardless of the fluctuation of the pressure exerted on the ports. In this study, AC solenoid valves that posses the high-speed responsibility and the high rate of flow have designed and analyzed through the law of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, Flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

Research of a high efficiency isolated bidirectional AC-DC converter for DC distribution system (DC 배전 시스템을 위한 고효율 절연형 양방향 AC-DC 컨버터 개발에 대한 연구)

  • Kim, Ho-Sung;Jung, Jee-Hoon;Ryu, Myung-Hyo;Kim, Jong-Hyun;Baek, Ju-Won
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.369-370
    • /
    • 2012
  • 본 논문은 380V DC 배전 시스템의 양방향 전력 흐름 제어와 전력 변환 효율 개선을 위한 고효율 절연형 양방향 AC-DC 컨버터를 제안한다. 제안하는 회로는 비절연형 양방향 AC-DC 정류기와 절연형 양방향 CLLC 공진형 컨버터로 구성된다. AC-DC 정류기의 전력 변환 효율 높이기 위해서 단극성 SPWM 방식을 이용하여 SiC 다이오드와 Anti-parallel 다이오드가 없는 IGBT와 MOSFET를 이용하여 전력 변환 효율을 증가 시켰다. 절연형 양방향 DC-DC 컨버터의 효율을 높이기 위해서 전 범위 ZVS 동작이 가능한 양방향 CLLC 공진형 컨버터를 이용하였다. 5kW 시제품을 통하여 제안하는 절연형 양방향 AC-DC 컨버터의 성능을 검증하였다.

  • PDF

Case of the Channel Restructuring for the Processed Agri-Products of National Agricultural Cooperative Federation (농협 가공식품의 유통경로 체계화를 위한 판매대행센타 설립에 관한 사례)

  • 김상용;유창조;김세나;최진표
    • Journal of Distribution Research
    • /
    • v.4 no.3
    • /
    • pp.87-103
    • /
    • 2000
  • Throughout the nation, each local Agricultural Cooperative (AC) has built its own agri-products processing factory in order to provide the steady demand source for the locally produced agri-products. However, each factory of AC has performed poorly with no competitive advantages against the national brands of private companies. Thus, from the perspective of the National Agricultural Cooperative Federation (NACF), the current situation of unorganized and inefficient management of the factories under the control of each local AC needs to be improved. In this case analysis, we introduce the problems of the AC factories and discuss the NACF's approach to solve the problems. In particular, given that AC as well as NACF are the non-profit organizations, it is worthwhile to fay special attention to the process of restructuring the system of distribution channels for the processed agri-products with the concept of marketing.

  • PDF

Research on the Effect of Interconnected Distributed Wind Power Generation(225[kV], AC Link Method) on Power Quality in System (연계형 풍력발전설비(225[kV], AC 링크방식)가 전력계통의 전원 품질에 미치는 영향에 관한 연구 분석)

  • Na, Chae-Dong;Park, Jung-Shin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.147-153
    • /
    • 2010
  • When small scale wind and solar power generation systems are connected to conventional power distribution system. It is worried that it can affect the quality of electricity such as voltage variation, power factor, frequency, harmonics and flicker. Therefore, in this research, in order to investigate the effects of wind power generation equipments(AC link method) on electrical power quality, when they are connected to distribution system. Power quality analyzer was installed respectively at the front side of power conversion system of conventional wind generation system and secondary side of consumer's power supply at distribution line. Measurements on power quality were performed and the effects of the wind generation system on distribution system were analyzed when it was and was not operated. The results show that 0.34[%] increase on voltage variation, 0.145 increase on current crest factor and 0.6[$^{\circ}$] deviation on phase difference when the power generation system was operated.