• Title/Summary/Keyword: AC coupling

Search Result 144, Processing Time 0.025 seconds

Palladium-Catalyzed Cross-Coupling Reaction and Gold-Catalyzed Cyclization for Preparation of Ethyl 2-Aryl 2,3-Alkadienoates and α-Aryl γ-Butenolides

  • Mo, Jun-Tae;Hwang, Hoon;Lee, Phil-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.spc8
    • /
    • pp.2911-2915
    • /
    • 2011
  • Efficient synthetic method for the preparation of ethyl 2-aryl-2,3-alkadienoates through Pd-catalyzed selective allenyl cross-coupling reactions of aryl iodides with organoindiums generated in situ from indium and ethyl 4-bromo-2-alkynoate was developed. The cyclization reaction of ethyl 2-aryl-2,3-alkadienoates catalyzed by $AuCl_3$ and AgOTf in the presence of AcOH or TfOH produced various ${\alpha}$-aryl ${\gamma}$-butenolides or ${\gamma}$-substituted ${\alpha}$-aryl ${\gamma}$-butenolides.

Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement (부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가)

  • Park, Dae-Won;Choi, Su-Yeon;Choi, Jae-Sung;Kil, Gyung-Suk;Lee, Kang-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1887-1891
    • /
    • 2008
  • In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

  • PDF

A Study on Thermal, Mechanical and Electrical Properties as Silane Treated Epoxy/MICA Composites (실란처리된 Epoxy/MICA 콤포지트의 열적, 기계적 전기적 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.213-218
    • /
    • 2013
  • In this study, epoxy/mica composite was prepared by mixing with mechanical stirrer together with homogenizer, and the effect of amino-type silane coupling agent was also studied. To reduce the viscosity without any decrement of other properties, 1,4-Butanediol diglycidyl ether (1,4-BDGE) as an aliphatic epoxy reactive diluent was introduced to the epoxy/mica composite in order to use as vanish for high voltage motor and generator stator winding. It was confirmed by scanning electron microscopy (SEM) observation that interfacial characteristics between organic epoxy and inorganic mica was modified by coupling agent treatment so that glass transition temperature increased, and tensile strength and electrical breakdown strength increased. The properties were estimated by Weibull statistical analysis and the ac electrical breakdown strength was 20.2% modified by treating silane coupling agent.

Prediction of EFT/B Signal Transfer Characteristics in Mobile Charging Circuit (모바일 충전회로에서 EFT/B 신호의 전달특성 예측에 대한 연구)

  • Song, SeungJae;Kim, Kwangho;Jo, Jeongmin;Lee, Seungbae;Kim, So-young;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.10
    • /
    • pp.895-906
    • /
    • 2015
  • This paper presents a methodology and a model that can analyze the high frequency transfer characteristics from socket in the AC power port to the 5 V DC output port in the mobile charging circuit. This is to predict the output signals coming from the IEC(International Electrotechnical Commission) Standard(IEC 61000-4-4), EFT/B(Electric Fast Transient and Burst) immunity test for mobile charging circuit. Since the mobile charging circuit is energized from the AC power socket from the power line, it is necessary to know the high frequency transfer characteristics with activated AC power line. A simple CDN(Coupling-Decoupling Network) is designed and manufactured for measuring S-parameters of mobile charging circuit with and without AC power line activated. The result shows that the S-parameters of the specific mobile charging circuits are almost the same, independent of AC power line activation. Consequently, the S-parameters without AC line could be used to predict the output response to the EFT/B signals, and it was shown that the proposed methodology predicts the output responses quite accurately, which proves the validness of the methodology presented in this paper.

An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters (PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단)

  • Shon, Jin-Geun;Na, Chae-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

An Estimation of Life Time in Epoxy composites using Weibull Distribution Equation (와이블 분포식을 이용한 에폭시 복합체의 수명 시간 예측)

  • 신철기;김진사;정일형;임장섭;김태성;이준웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.3
    • /
    • pp.167-173
    • /
    • 1998
  • In order to estimate the life time of epoxy composites used for modeling material of transformer, the AC breakdown experiments of it were experimented and then the AC breakdown data were also simulated by Weibull distribution equation in this study. The life time of H100F65 specimen was the shortest and it of SH100F65 specimen was the longest, and as the AC voltage was applied to specimen for 50[min], the breakdown probability of each specimen was 31.2[%], 17.00[%], 84.36[%] and 12.35[%], respectively.

  • PDF

AC Loss Characteristics of Multifilamentary HTS Tapes

  • Amemiya, Naoyuki
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.69-72
    • /
    • 2000
  • AC losses in multifilamentary HTS tapes can be classified to hysteresis loss, coupling loss, and eddy current loss from the viewpoint of their generation mechanism. From the viewpoint of the major magnetic field component generating them, they can be classified to magnetization loss, transport loss, and total loss. Dividing superconductor to fine filaments, twisting filaments bundle and increasing transverse resistivity are effectively reduce magnetization loss and total loss when the external magnetic field is relatively large. Recently, twisted multifilamentary Bi 2223 tapes with pure silver matrix were fabricated and the reduction of magnetization loss was proved experimentally in the parallel magnetic field to the tape wide face. However, when the perpendicular magnetic field is applied, increasing transverse resistivity is required essentially to reduce the AC losses. The transverse resistivity was increased successfully by the introduction of resistive barrier between filaments.

  • PDF

A Study on The 4-Parallel Operation of PWM Converter for High Speed Train Auxiliary Block (고속전철 보조전원 장치용 PWM컨버터의 4병렬 운전에 관한 연구)

  • Oh, G.W.;Kim, Y.C.;Won, C.Y.;Choi, J.M.;Ki, S.W.;Bae, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1230-1232
    • /
    • 2000
  • To reduce harmonics in the AC line and achieve a unit power factor, A 4 paralled single phase PWM AC/DC converter has been proposed. In this paper, the coupling components are derived analytically from PWM converter input transformer model and control scheme to solve this problem is proposed. Unit power factor was obtained and the AC-side current harmonics were reduced. Simulation results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

Study on Frequency Characteristics of Rectangle Spiral Planar Inductor (사각 나선형 평면 인덕터의 주파수 특성에 관한 연구)

  • Kim, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2330-2334
    • /
    • 2014
  • In this study, we confirmed the frequency characteristics of planar spiral inductor based on non-contact method AC coupling for wireless signal transmission. The dielectric constant variation of the substrate does not directly effect the inductance of device but effect the electrostatic capacity of device. Therefore, its change self-resonance frequency. The thickness increment of the substrate increase inductance but decrease self-resonance frequency. Because, the thickness decrement of the substrate make the inside electrostatic capacity increment.

Fabrication of the Optical Fiber-Photodiode Array Module Using Si v-groove (실리콘 v-groove를 이용한 광섬유-광검출기 어레이 모듈 제작)

  • 정종민;지윤규;박찬용;유지범;박경현;김홍만
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.88-97
    • /
    • 1994
  • We describe the design, fabrication, and performance of the optical fiber-photodiode 1$\times$12 arry module using mesa-type InS10.53T GaS10.47TAS/INP 1$\times$12 PIN photodiode array. We fabricated the PIN PD array for high-speed optical fiber parallel data link optimizing quantum efficiency, operating speed sensitivity from the PIN-FET structure, and electrical AC crosstalk. For each element of the array, the diameter of the photodetective area is 80 $\mu$m, the diameter of the p-metal pad is 90 $\mu$m, and the photodiode seperation is 250 $\mu$m to use Si v-groove. Ground conductor line is placed around diodes and p-metal pads are formed in zigzag to reduce Ac capacitance coupling between array elements. The dark current (IS1dT) is I nA and the capacitance(CS1pDT) is 0.9 pF at -5 V. No signifcant variations of IS1dT and CPD from element to element in the array were observed. We calulated the coupling efficiency for 10/125 SMF and 50/125 GI MMF, and measured the responsivity of the PD array at the wavelength is 1.55 $\mu$ m. Responsivities are 0.93 A/W for SMF and 0.96 A/W for MMF. The optical fiber-PD array module is useful in numerous high speed digital and analog photonic system applications.

  • PDF