• Title/Summary/Keyword: AC corona discharge

Search Result 51, Processing Time 0.022 seconds

Electrohydrodynamic Characteristics of AC Corona Discharge for the Frequency (교류 코로나 방전시 주파수 변화에 따른 전기유체역학적 특성)

  • Jung, Jae-Seung;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.87-92
    • /
    • 2012
  • In this paper, EHD(electrohydrodynamics) characteristics of AC corona discharge for the various frequency was investigated. Ionic wind velocity is controlled by the frequency of applied ac high voltage, and maximum velocity of the ionic wind is obtained at 1.2kHz. Maximum velocity are 1.90 m/s by metal corona electrode and 2.72m/s by wet porous corona electrode, These attain 91~99% of the maximum velocity in the DC corona discharge by adjusting the frequency through the experiments. In this paper, wet porous corona electrode has high possibility of cooling methode because a AC corona discharge using wet porous corona electrode is able to eject more water droplets than DC corona discharge.

The Comparison of Adhesion Properties on Polyester Fabric by AC and DC Corona Treatment (AC와 DC 코로나 처리에 따른 폴리에스테르 직물의 접착성질 비교)

  • Lee, Jae Ho
    • Journal of Adhesion and Interface
    • /
    • v.17 no.3
    • /
    • pp.104-109
    • /
    • 2016
  • Compare AC corona and DC corona treatment effects, polyester fabrics were AC corona treated with different current intensity (5, 10, 15 A) and feeding speed (5, 10, 15 m/min) as the same DC corona treatment conditions of the preceding research. We confirmed the surface change of polyester fabrics using scanning electron microscopy (SEM) and X-ray photoelectron spectrometer (XPS), and the change of physical properties through measuring the dry and wet bonding strength. The surface changes of polyester fabrics by treating in air atmosphere with AC corona discharge are shown similar tendency with DC corona discharge. Generally dry bonding strength were increased with increasing current intensity and feeding speed, but wet bonding strength were increased with increasing current intensity and decreasing feeding speed in both AC and DC corona treatment. When the current is 20 A, carbonization occurs in DC corona discharge but carbonization does not occur in DC corona discharge.

Corona Discharge Characteristics of Transformer Bushing Model with Contaminnations in Air (오염물질에 따른 변압기부싱 모델의 기중 코로나 방전 특성)

  • Pang, Man-Sik;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.91-96
    • /
    • 2012
  • The surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations in air is serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics of surface flashover model with contaminations in air. Also, UV images of discharge and corona pulse count in air are analyzed using prototype UV camera of Korea and a UV sensor with an optic lens. These results are studied at both AC and DC voltage under a non-uniform field.

Effect of Long-term Corona-discharge on RTV Silicone Rubber (장기 코로나 처리에 따른 RTV 실리콘 절연재료의 특성변화)

  • Youn, Bok-Hee;Ahn, Jong-Sik;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.266-269
    • /
    • 2001
  • This paper investigated the aging characteristic under long-term corona discharge on roan temperature vulcanized silicone rubber, which has been using as a protective coating material for solving the contaminant problem. The applied electrical field is 10kV/cm ac and corona discharge treatment was applied on RTV silicone rubber sheet for maximum 250 hours. With the duration of corona discharge. the diffusible low molecular weight species increased, which was determined the usage of n-hexane extraction method. In addition, the contaminant layer was formed on the treated surface, and then measured the contact angle. We investigated the relation of contact angle and diffusible low molecular weight species. It is found that scissor of main chain PDMS and side chains $(CH_3)$ and the generation of LMW species were occurred by a corona discharge. The improvement of hydrophobicity rate is thought due to the increase of diffusible LMW species.

  • PDF

Effect of Long-term Corona-discharge on RTV Silicone Rubber (장기 코로나 처리에 따른 RTV 실리콘 절연재료의 특성변화)

  • 연복희;안종식;허창수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.266-269
    • /
    • 2001
  • This paper investigated the aging characteristic under long-term corona discharge on loon temperature vulcanized silicone rubber, which has been using as a protective coating material for solving the contaminant problem. The applied electrical field is 10kV/cm ac and corona discharge treatment was applied on RTV silicone rubber sheet for maximum 250 hours. With the duration of corona discharge, the diffusible low molecular weight species increased, which was determined the usage of n-hexane extraction method. In addition, the contaminant layer was formed on the treated surface, and then measured the contact angle. We investigated the relation of contact angle and diffusible low molecular weight species. It is found that scissor of main chain PDMS and side chains (CH$_3$) and the generation of LMW species were occurred by a corona discharge. The improvement of hydrophobicity rate is thought due to the increase of diffusible LMW species.

  • PDF

Location and Frequency Domain Detection of Corona Discharge Point in Oil Using AE Sensor (AE센서를 이용한 유중 코로나방전점 위치 및 주파수 영역 검출)

  • 이상우;김성훈;김인식;김기채;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.127-131
    • /
    • 1999
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane electrode was analyzed to determine the proper ultrasonic sensor. We also examined the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] AC high-voltage in oil. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were found to be 130[kHz] by the fast fourier transform. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages. Also the detection of corona discharge point location by AE signals was found to be possible by using two sensors.

  • PDF

Corona Discharge and Ozone Generation Characteristics of a Wire-to-Wire Gap with a Ferroelectric Pellet Bed (강유전체 충진 선대선 방전갭의 코로나 방전 및 오존 발생특성)

  • Shin, Jung-Min;Bae, Chang-Hwan;Ahn, Chang-Jin;Lee, Jong-Hoon;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1873-1875
    • /
    • 2003
  • Surface corona discharge characteristics of a ac corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charged stored on the surfaces of the ferroelectric pellets by a at corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between wire electrodes. As a result, in the case of the corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be generated efficiently. It is also found that, the ferroelectric pellet barrier discharge reactor had better discharge characteristics for plasma generation than the wire-to-wire discharge reactor without pellets.

  • PDF

The Characteristics of Decomposition of NOx by Superposing Discharge Plasma Reactor (중첩 방전 반응기에 의한 NOx의 분해 특성)

  • ;;;;;山常 端樹
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.32-37
    • /
    • 1999
  • The superposing effect of SPCP(Surfoce Induced Plasma Chemical Process) and corona discharge has been studied for rerroval of NOx from industrial flue gases. NOx rermval rates by SPCP, corona discharge and superposing discharge were monitored and compared. Parameters were the concentration and the flow rate of gas, frequency and the type of discharge. Experirrental results showed that NOx removal rate by sUIffPOSing discharge was 10-15[%] higher than that by the other two modes. The higher NOx. rermval rate was observed with the lower frequency of upper electrode in the combined reactor and with the higher frequency of lower electrode. 'The maximum obtainable NOx. rerroval rate by SPCP (18 [W]) and corona discharge (8.5 [W]) was 80[%] and 10[%], respectively. With the combination of the two modes, however, 90[%] of NOx removal rate was observed with the discharge power of 14 [W].14 [W].

  • PDF

Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame (핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향)

  • Lee, Jae-Bok;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

Corona Discharge and Ozone Generation Characteristics of a Wire-to-Wire Plasma Reactor with a Ferroelectric Pellet Layer (강유전체층을 갖는 선대선 방편 플라즈마장치의 코로나 방전 및 오존발생 특성)

  • 문재덕;신정민;한상옥
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.7
    • /
    • pp.377-381
    • /
    • 2004
  • A discharge plasma reactor using a ferroelectric pellet packed bed is now used as a removal means of pollutant gases, such as NOx, SOx and VOCs. When an ac voltage is applied to this plasma reactor, then the pellets are polarized, and great electric fields are formed at each top and bottom contact points of the ferroelectric pellets. Thus the points of each pellet become covered with intense corona discharges, where an electrophysicochemical reaction is taking place strongly However these strong discharges also elevate the temperature of the pellets greatly and concurrently decrease the output ozone generation, as a result, the overall removal efficiency of gas becomes decreased greatly A new configuration of discharge plasma reactor using a ferroelectric pellet layer and a wire-to-wire electrode has been proposed and investigated experimentally. It is found that an intensive microdischarge is taking place on the surface of ac corona-charged ferroelectric pellet layer of the proposed reactor, which concurrently enhances the efficiency of plasma generation greatly And, this type of configuration of plasma reactor utilizing a wire-to-wire electrode and a ferroelectric pellet layer could be used as one of effective plasma reactors to remove pollutant gas.