• Title/Summary/Keyword: AC Power Source

Search Result 524, Processing Time 0.026 seconds

System Development for Education and Design of a Nonlinear Controller with On-Line Algorithm

  • Park, Seong-Wook
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.2
    • /
    • pp.215-221
    • /
    • 2003
  • The education system in this paper is used to demonstrate and educate the effects of electromagnetic induction. Placing an aluminum ring over the core and switching on AC source causes the ring to jump in the air due to induced currents in the ring producing a magnetic field opposed to that produced in the core. To control the position of the ring by only the current, it is to require nonlinear control algorithm and control board that is composed of photo sensors, decode circuit, computer communication, and power electronics circuit. This paper provides the development for education system in detail and the effects of dynamic neural networks for nonlinear control with on line is studied.

Enhanced Phase Angle Detect Method Using High-pass Filter (고주파 필터를 이용한 개선된 위상각 검출 방법)

  • Heo, Min-Ho;Song, Sung-Gun;Kim, Gwang-Heon;Nam, Hae-Gon;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2370-2378
    • /
    • 2009
  • The enhanced phase angle estimation algorithm is essential to supply the power stably under synchronizing with grid source. In this paper, we are proposed the novel phase angle estimation algorithm and verified the validity of proposed method as simulation with PSIM and experiments. We sort the harmonics element using high-pass filter(HPF) that have the cut-off frequency below basic element and make reverse d-q transformation. So, it can be restored the harmonics element at stationary axis, and we can get the fundamental voltage element of AC grid. Proposed PLL method have a rapid responsibility and a large margin at controller design than conventional method because it have a small phase delay and a sufficient controller gain margin. And, it can reduce the error of voltage rms value and axis transformation according to robust PLL algorithm against the harmonic and phase unbalance.

The Characteristics of Multi Gap Type Ozonizer (다중 간극형 오존발생장치의 특성)

  • 김금영;문경수;전병준;박용권;김상구;김영훈;김영길;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.145-148
    • /
    • 1999
  • In this paper, multi gap type ozonizer(MGO) has been designed and manufactured. The ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode) of cylinder shape. This paper describes the following two characteristics: $\circled1$ The characteristics of discharge with variation of output voltage of AC H.V source, flux of oxygen supplied gas and discharge voltage. $\circled2$ The characteristics of ozone generation by varying flux and discharge power.

  • PDF

Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer (다중방전형 오존발생기의 방전 및 오존생성특성)

  • Chun, Byung-Joon;Mun, Kyung-Su;Song, Hyun-Gik;Kim, Keum-Yeung;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF

A Basic Study of Development of Electrostatic Induction Motor (정전유도형모터의 개발을 위한 기초연구)

  • 이동훈
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.58-68
    • /
    • 1994
  • A miniature size electrostatic induction motor has been fabricated and studied parameters Influencing dominantly to the motor speed, such as a voltage and frequency of the 3 phase ac power source supplied to the stator of fabricated motor, the surface resistivity and relative dielectric constant of the rotor surface materials and the concurrently calculated relaxation time constants. It is found that the higher resitivity and/or the higher relative dielectric constant, concurrently the longer relaxation time constant of the rotor surface materials make the motor speed get higher speed. In case of discrete coated rotor surface it is found that the motor speed was increased logarithmically as narrow as width of the discrete coated Ti. And the degree of width of discrete coated Ti to the axial direction of the rotor was 60$^{\circ}$ and 150$^{\circ}$, the motor has got a 125% higher than that at the degree of 0$^{\circ}$.

  • PDF

Fault Diagnosis and Neutral Point Voltage Control Under the Switch Fault in NPC 3-Level Voltage Source Inverter (NPC 3-레벨 인버터의 스위치 고장시 고장 진단과 중성점 불평형 전압 제어)

  • Kim Tae-Jin;Kang Dae-Wook;Hyun Dong-Seok;Son Ho-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.231-237
    • /
    • 2005
  • Many conventional multi-level inverters have detected switching faults by using the over voltage and current. However, fault detection of the switching elements is very difficult because the voltage and current due to each switching fault decrease more than the normal operation. Moreover, the dc-link unbalancing voltage causes a serious problem in the safety and reliability of system when the 3-level inverter faults occur Therefore, this paper proposes the simple fault diagnose method and the neutral-point-voltage control method that can protect the 3-level inverter system from the unbalancing voltage of the do-link capacitors when the faults of switching elements occur in the 3-level inverter that is very efficient in ac motor drives of the high voltage and high power applications. Through experiment results, the validity of the proposed method is demonstrated.

The Characteristics of Showering Discharge Type Ozonizer (Showering Discharge형 오존발생장치의 특성)

  • Kim, Keum-Yeung;Mun, Kyung-Su;Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In;Jeon, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2248-2250
    • /
    • 1999
  • In this paper, showering discharge type ozonizer has been designed and manufactured. The ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode) of cylinder shape. This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flux of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flux and discharge power.

  • PDF

Characteristics of a Superposed Discharge Type Ozonizer(III) (중첩방전형 오존방생기의 특성(III))

  • Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In;Kim, Gi-Chae;Lee, Dong-Heon;Kim, Geum-Young;Lee, Chun-Ha;Jeun, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1815-1817
    • /
    • 1998
  • In this paper, a superposed discharge type ozonizer(IESDO) has been designed and manufactured. IESDO is equipped with three electrodes(central, internal and external electrodes), and it is composed of two gaps. Ozone is generated by overlapping silent discharge, which is respectively came from two gaps. This paper describes the following characteristics : (1) The characteristics of discharge with variation of output voltage of AC H.V source, quantity of supplied gas and discharge voltage (2) the characteristics of ozone generation with variation of quantity of supplied gas, discharge power, operating number of IESDO.

  • PDF

Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency (발진주파수 및 전도도를 통한 오손도 자동측정)

  • 최남호;구경완;이명섭;한상옥;정재기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

MODELING, ANALYSIS AND CONTROL OF STATIC VAR COMPENSATOR USING THREE-LEVEL INVERTER (3-레벨 인버터를 사용한 무효전력 보상기의 모델링, 해석 및 제어기 설계)

  • Cho, Guk-C.;Choi, Nam-S.;Cho, Gyu-H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.764-766
    • /
    • 1993
  • A new static var compensator(SVC) system using three-level inverter is proposed for high voltage and high power applications. A general and simple model for the overall system is obtained using circuit DQ-transform and DC and AC analyses are achieved to characterize the open-loop system. Using the proposed model, a new control method which controls both the phase angle and modulation index of switching pattern simultaneously is suggested to provide fast response of SVC system without using independent voltage source. Finally, predicted results are verified by computer simulation.

  • PDF