• Title/Summary/Keyword: AC Power Source

Search Result 524, Processing Time 0.024 seconds

A Level Dependent Source Concoction Multilevel Inverter Topology with a Reduced Number of Power Switches

  • Edwin Jose, S.;Titus, S.
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1316-1323
    • /
    • 2016
  • Multilevel inverters (MLIs) have been preferred over conventional two-level inverters due to their inherent properties such as reduced harmonic distortion, lower electromagnetic interference, minimal common mode voltage, ability to synthesize medium/high voltage from low voltage sources, etc. On the other hand, they suffer from an increased number of switching devices, complex gate pulse generation, etc. This paper develops an ingenious symmetrical MLI topology, which consumes lesser component count. The proposed level dependent sources concoction multilevel inverter (LDSCMLI) is basically a multilevel dc link MLI (MLDCMLI), which first synthesizes a stepped dc link voltage using a sources concoction module and then realizes the ac waveform through a conventional H-bridge. Seven level and eleven level versions of the proposed topology are simulated in MATLAB r2010b and prototypes are constructed to validate the performance. The proposed topology requires lesser components compared to recent component reduced MLI topologies and the classical topologies. In addition, it requires fewer carrier signals and gate driver circuits.

Stand-Alone Wind Energy Conversion System with an Asynchronous Generator

  • Singh, Bhim;Sharma, Shailendra
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.538-547
    • /
    • 2010
  • This paper deals with a stand-alone wind energy conversion system (WECS) with an isolated asynchronous generator (IAG) and voltage and frequency (VF) control feeding three-phase four-wire loads. The reference generator currents are estimated using the instantaneous symmetrical component theory to control the voltage and frequency of an IAG system. A three-leg voltage source converter (VSC) with an isolated star/delta transformer is used as an integrated VSC. An integrated VSC with a battery energy storage system (BESS) is used to control the active and reactive powers of the WECS. The WECS is modeled and simulated in MATLAB using the Simulink and the Sim Power System (SPS) toolboxes. The proposed VF controller functions as a voltage and frequency regulator, a load leveler, a load balancer and a harmonic eliminator in the WECS. A comparison is made on the rating of the VSC with and without ac capacitors connected at the terminals of an IAG. Simulation and test results are presented to verify the control algorithm.

Analysis of Noise Reduction Performance for Noise Cut Transformer (Noise Cut Transformer의 노이즈 억제성능 분석)

  • Lee, Jae-Bok;Huh, Chang-Su;Lee, Ki-Chul;Myung, Sung-Ho;Ha, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1784-1786
    • /
    • 1996
  • It is necessary to eliminate the broad band noise which frequency is in a few kHz to MHz in the AC line to supply the power to electrical and electronic control equipments. Because this kind of noise could damage the device or could be a source of malfunction, many devices like a filter and surge suppressor are developed to cut off the noise. But those device could not disconnected from the power line, so it remain some problem and on be used in limited area, In this paper, we present performance test results NCT(noise Cut Transformer) with excellent performance for reducing the high frequency noise and surge existing in the power line.

  • PDF

A Study on the Analysis of the Output Waveform of Three-Phase Regular Sampling PWM Inverter (3상 레귤러 샘플링 PWM 인버터의 출력파행 분석에 관한 연구)

  • 노창주
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.3
    • /
    • pp.274-285
    • /
    • 1992
  • Among various Power converters, a variable voltage variable frequency (VVVF) three-phase PWM inverter is regarded as most promising power converter due to its capabilities, which permits the control of voltage, frequency and harmonic contents in a single power stage employing only on DC source. As a modulating technique of the PWM inverter, the regular sampling technique has rendered possible the on-line computation and generation of PWM control waveforms with a reasonably high switching frequencies. In this paper, microprocessor based three-phase regular samping PWM inverter with real-time control algorithm and control circuits for driving three phase AC motor has been developed. Harmocic components of PWM waveform were analized theoretically in terms of Bessel function series and then calculated by digital computer and observed with spectrum analyzer.

  • PDF

New Current-fed GTO Inverter and Its Basic Characteristics (전류형 GTO Inverter와 그 기본특성)

  • ;Kouki MATSUE
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.1
    • /
    • pp.3-8
    • /
    • 1987
  • The conventional autosequentially commutated current-fed inverter (ASCI) is widely employed with the induction motor drives for speed control. Howener, this inverter has a limit of high power and high frequency indution motor drives. One of the limitations is to be found in the commutation capacitors in the main circuit of this inverter. A new current-fed gate turn-off thyristor (GTO) inverter is developed. This inverter is composed of the main GTO bridge configuration and the improved energy rebound circuit (ERC)without the commutation capacitor. This inverter works stable at high frequency from light load to heavy one. The improved ERC is used not only to rebound the load reactive power to the dc link, but also to return the power in the load to the ac source. The new GTO inverter circuit and the characteristics of the inverter induction motor drives are explained and analyzed.

  • PDF

Novel Current Controlled PWM-VSC Converter Using Current Error Vector Control (전류오차 백터 제어방식에 의한 새로운 형태의 전류 제어 PWM 전압형 정류기)

  • 박민호;최재호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.4
    • /
    • pp.261-268
    • /
    • 1989
  • A novel current controlled PWM voltage source type converter and control strategy is proposed that is able to draw nearly sinusoidal current at unity power factor from three phase power lines. Current error vector control scheme is used which has two operating states : low harmonic current content state and quick current response state. The state is changed according to the current error to optimize the steady state and transient state performances. To regulate the dc oupput voltage, the magnitude of the reference current is determined by a controller dc voltage error. The ac input power factor can be controlled with unity, and even leading or lagging by adjusting the relative position of the reference current with respect to the supply voltage.

  • PDF

A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization (PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구)

  • Ahn Jong-Bo;Kim Won-gon;Hwang Ki-Hyun;Park Jun-H
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

A Study on the Three-Phase Active Power Filter using Predictive Current Control Method (예측전류제어방식을 이용한 3상 능동전력필터에 관한 연구)

  • Kwon, Byung-Gi;Woo, Myung-Ho;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.138-140
    • /
    • 1994
  • In this paper, a three-phase active power filter using voltage- source PWM converter is designed to eliminate the harmonics and compensate the reactive power in the ac side. The predictive current control method is adopted, which provides constant switching frequency and low current ripple but has inherently one sampling error between the command and the actual current. Here we propose the algorithm which corrects this delay time. The converter voltage obtained from this current control can be accomplished by the space vector modulation method at a voltage-type converter. All control sequences of active filter is executed by a DSP which is designed to calculate floating points at very hight speed. Finally, the validity of this filter using the predictive current control method is demonstrated through experimental results.

  • PDF

DC Leakage Current Properties Analysis of the LED Lamps of Road and Landscape Lighting (LED 가로등 및 경관조명의 직류 누전 특성 분석)

  • Kim, Hyang-Kon;Kim, Dong-Woo;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.885-891
    • /
    • 2011
  • In this paper, we studied dc leakage current properties analysis of LED lamps of road and landscape lighting when leakage current appeared in dc power line. Generally, converter of LED lighting is divides to insulated type and non-insulated type according to components. When electric leakage happened in AC power line, earth leakage breaker(ELB) senses leakage current and interrupts electric circuit. In dc power source, We need experimental verification about dc electric leakage for electricity safety. In normal wiring conditions and in the water, in case of using insulated type of converter, dc leakage current did not occur. However, in case of using non-insulated type of converter, dc leakage current occurred and passed through into the ground. We found that there is a hazard of electric shock by dc leakage current. We expect that the results of these studies would be helpful for electrical safety of LED lamps for road and landscape lighting.

Direction for Development of Energy Regeneration Device for DC Electric Railway System (DC전철구간의 에너지회생장치 개발 방향)

  • Kim, Yong-Ki;Bae, Chang-Han;Han, Moon-Seob;Yang, Young-Chul;Jang, Su-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF