The new Soft-Switching AC-DC Boost Type Converter using Lossless Snubber (무손실 스너버회로를 이용한 새로운 소프트 스위칭 AC-DC승압형 컨버터)

  • Mun Sang-Pil;Suh Ki-Young;Kim Young-Mun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1226-1228
    • /
    • 2004
  • A novel lossless passive snubber is proposed for soft switching the boost type converters. The proposed snubber does not use any auxiliary switches. but uses two identical snubber capacitors which are charged in parallel at turn off of the main switch and discharged in series at turn on automatically, and the discharged energy is recovered effectively (more than $95[\%]$ recovery) into the output capacitor. Thus, the snubber provides zero voltage switching for the converter main switch, reducing both the turn off losses and the electromagnetic interference(EMI) noise, whitch improves the converter performance. The experimental results of a 20[kHz] 600[W] DC-DC boost converter and a single-phase AC-DC boost rectifier with the new snubber are presented.

  • PDF

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

Design and Reliability Evaluation of 5-V output AC-DC Power Supply Module for Electronic Home Appliances (가전기기용 직류전원 모듈 설계 및 신뢰성 특성 해석)

  • Mo, Young-Sea;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.504-510
    • /
    • 2017
  • This paper presents an AC-DC power module design and evaluates its efficiency and reliability when used for electronics appliances. This power module consists of a PWM control IC, power MOSFETs, a transformer and several passive devices. The module was tested at an input voltage of 220V (RMS) (frequency 60 Hz). A test was conducted in order to evaluate the operation and power efficiency of the module, as well as the reliability of its protection functions, such as its over-current protection (OVP), overvoltage protection (OVP) and electromagnetic interference (EMI) properties. Especially, we evaluated the thermal shut-down protection (TSP) function in order to assure the operation of the module under high temperature conditions. The efficiency and reliability measurement results showed that at an output voltage of 5 V, the module had a ripple voltage of 200 mV, power efficiency of 73 % and maximum temperature of $80^{\circ}C$ and it had the ability to withstand a stimulus of high input voltage of 4.2 kV during 60 seconds.

Analysis of QoS in WLAN : Analysis of 802.11ac wireless LAN service in Korea (국내 무선 랜 서비스 현황 분석)

  • Kim, HyunHo;Bruce, Ndibanje;Jang, Won-Tae;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.104-107
    • /
    • 2014
  • Nowadays, smart devices such as smart phones, tablets PC, etc... are exchanging messages using WLAN(Wi-Fi) technologies for sending and receiving messages. With the growth of the smart devices users, the WLAN (Wi-Fi) medium communication could be loaded and then the Quality of Service is undesirable. Currently, there are five types of Wireless LAN such as802.11 a / b / g / n / ac supporting the communication between smart devices and the most used it WLAN 802.11n. Unfortunately, if the WLAN 802.11n is being used by a lot of users, there is poor Quality of Service due to the interference. In this paper, we analyze the Quality of Service provided by the 802.11n and compare with the next generation of wireless 802.11ac.

  • PDF

Interference Cancellation for Wireless LAN Systems Using Full Duplex Communications (전이중 통신 방식을 사용하는 무선랜을 위한 간섭 제거 기법)

  • Han, Suyong;Song, Choonggeun;Choi, Jihoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.12
    • /
    • pp.2353-2362
    • /
    • 2015
  • In this paper, we employ the single channel full duplex radio for wireless local area network (WLAN) systems, and design digital interference cancellers using adaptive signal processing. When the full duplex scheme is used for WLAN systems with multiple transmit and receive antennas, some interference is caused through the feedback of transmit signals from multiple antennas. To remove the feedback interference, we derive the least mean square (LMS), normalized LMS (NLMS), and recursive least squares (RLS) algorithms based on adaptive signal processing techniques. In addition, we analyze the theoretical convergence of the proposed LMS and RLS methods. The channel capacity of full duplex radios increases by two times than that of half duplex radios, when the packet error rate (PER) performances for the two systems are identical. Through numerical simulations in WLAN systems, it is shown that the full duplex method with the proposed interference cancellers has a similar PER performance with the conventional half duplex transmission scheme.

Design of IIR Notch Filter for Removal of Baseline wander and Power Line Interference from ECG Signal

  • Chivapreecha, Sorawat;Dejhan, Kobchai;Yimman, Surapan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.848-851
    • /
    • 2005
  • This paper proposes a design of IIR notch filter with modified pole placements. The pole angle is derived from quadratic programming to find the appropriate pole position on the unit circle in z-plane in order to achieve the symmetry of the amplitude response. The simulation results are shown when compared with the conventional design technique. Moreover, it uses the TMS320C31 DSP chip for hardware implementation. Finally, the hardware implementation can be applied to removal of ECG baseline wander and elimination of AC power line interference in ECG signal.

  • PDF

Electromagnetic interference shielding materials using carbon nanotubes (탄소나노튜브를 이용한 전자파 차폐재)

  • 윤호규
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.33-36
    • /
    • 2003
  • AC and DC conductivity of the MWNT(Multi walled nanotubes)/polyurethane composites were investigated with respect to the various oxidative conditions, where these means acid concentration, treatment temperature, and treatment time. We suppose that the conditions of oxidation of the MWNTS have a certain influence on the degree of functionalization, damages, and dispersion of the MWNT themselves. Futhermore, the electrical properties of the resulting composites strongly depend on the oxidative conditions of MWNTS. The conductivity of the composites produced by using the optimal condition was measured as a function of frequency with volume content of MWNTS. These experimental results were analyzed using percolation theory Electromagnetic interference shielding effectiveness (SE) of the mixtures of polyurethane (PU), optimized MWNTs, and silver (Ag) is measured in the frequency range from 10 MHz to 6 ㎓ by using ASTM D4935-89. The measured SEs of the mixtures could be controlled from about 55 dB to 85 dB with the compositions of Ag/MWNT and compounding methods(C1, C2).

  • PDF

Time-division Visible Light Communication Using LED Lamp Light

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.145-150
    • /
    • 2015
  • We introduce a new method of time-division visible light communication (VLC) using LED lamp light for the generation of synchronizing pulses. The LED lamp, driven by an AC 220-V power line, radiates light that has a 120-Hz frequency component. The pulse generator in each VLC system receives the LED lamp light and generates the synchronizing pulses that are required for time-division transmission of multiple VLC channels. The pulse period is subdivided into several time slots for VLC channels. In experiments, 120-Hz synchronizing pulses were generated using LED lamp light, and three VLC channels were transmitted independently without interfering with each other in a condition where the VLC signals overlapped in space. This configuration is useful in constructing multiple wireless sensor networks that are safe and without interference in locations where LED lamps are used for illumination.

A Study on Pseudo DC Discharging Electronic Bal lasts for Fluorescent Lamp (의사 DC 방전용 형광등 전자 안정기에 관한 연구)

  • 이범익;정화진;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.11-15
    • /
    • 1992
  • Currently-using low-pressure lamps are usually drivel by the AC power supply. There are good and bad points according to high or low frequency in AC power driving type. For the low-pressure lamps, its efficiency increases and flicker decreases when it ignites at high frequency. So we already use the high-frequency electronic ballast of the low-pressure discharge lamps broadly. But there are EMI interference in high-frequency driving type because of giving the fluorescent lamp the high- frequency current. So recently, we have a tendency to compensate for that defects by DC driving method. As follows, we suggest pseudo DC discharging electronic bar lasts for fluorescent lamps which have the characteristics of high efficiency and no flicker by driving constant current boosted square wave.

  • PDF

ZVT PWM AC-DC Boost Converter with Active Snubber (능동 스너버를 갖는 ZVT PWM AC-DC 승압 컨버터)

  • Kim, Choon-Sam;Sung, Won-Ki;Lee, Jung-Moon;Choi, Chan-Sok;Kim, Soo-Hong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.214-220
    • /
    • 2008
  • Most of converter system could obtain almost unity power factor and make input current sinusoidal waveform, but they have many problems, such as electromagnetic interference and switching losses caused by switching noise in main switch. To solve these problems in hard switching PFC converter, soft switching converter using a resonant between capacitor and inductor is invented In this paper, advantages and disadvantages of conventional ZVT(Zero-Voltage-Transition) soft switching converter using a auxiliary resonant circuit is discussed. Then Improved ZVT soft switching converter proposed. This improved ZVT converter's operation principal, specific property, design scheme of main are described. From Simulation and experiment results of conventional ZVT soft switching and improved ZVT soft switching converter with active snubber, characteristics of the converter are confirmed.