• Title/Summary/Keyword: AC Current

Search Result 2,316, Processing Time 0.026 seconds

Comparison of Starting Current Characteristics for Three-Phase Induction Motor Due to Phase-control Soft Starter and Asynchronous PWM AC Chopper

  • Thanyaphirak, Veera;Kinnares, Vijit;Kunakorn, Anantawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1090-1100
    • /
    • 2017
  • This paper presents the comparison of starting current characteristics of a three-phase induction motor fed by two types of soft starters. The first soft starter under investigation is a conventional AC voltage controller on the basis of a phase-control technique. The other is the proposed asynchronous PWM AC chopper which is developed from the conventional synchronous PWM AC chopper. In this paper, the proposed asynchronous PWM AC chopper control scheme is developed by generating only two asynchronous PWM signals for a three-phase main power circuit (6 switching devices) from a single voltage control signal which is compared with a single sawtooth carrier signal. By this approach, the PWM signals are independent and easy to implement since the PWM signals do not need to be synchronized with a three-phase voltage source. Details of both soft starters are discussed. The experimental and simulation results of the starting currents are shown. It is found that the asynchronous PWM AC chopper efficiently works as a suitable soft starter for the three-phase induction motor due to that the starting currents are reduced and are sinusoidal with less harmonic contents, when being compared with the starting current waveforms using the conventional phase-control starting technique. Also the proposed soft starter offers low starting electromagnetic torque pulsation.

Improved AC/DC PFC ZVT Boost Converter (개선된 AC/DC PFC ZVT Boost 컨버터)

  • Ryu, Jong-Gyu;Kim, Yong;Bae, Jin-Yong;Lee, Eun-Young;Cho, Kyu-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.62-69
    • /
    • 2005
  • This paper presents the improved AC/DC PFC(Power-Factor-Correction) ZVT(Zero-Voltage-Transition) Boost Converter. The conventional AC/DC PFC ZVT Boost Converter minimizes the switching loss of the main switch within all of the load range. That is because AC/DC PFC ZVT Boost converter makes the main switch and the auxiliary switch turn on simultaneously so that it makes ZVS (Zero-Voltage-Switching) possible at the light load. However, it has two problems that ale large loss of the auxiliary switch and the increasing of the reverse current of the main switch. Therefore this research presents high efficiency to reduce the current stress of the auxiliary switch and the reverse current of main switch by adding a diode to the conventional ZVT converter. The prototype of 640[W], 100[kHz] system using MOSFET is implemented for this experimental verification.

A study on single body design of optical current sensor and optical voltage sensor (광전류/광전압 센서의 일체화 설계에 관한 연구)

  • 김영수;김요희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1596-1603
    • /
    • 1996
  • A single body type of fiber-optic current and voltae sensor using a rare earth doped YIG and a bismuth silicon oxide single crystsl is proposed, which is used for simultaneous measurement of the AC electric current and AC electric voltage over the trasmission lines. Experimental results showed that the fiber-optic current sensor has the maximum 7.5% error within the current range of 0A to 400A, and the fiber-optic voltage sensor has the maximum 0.87% error within the current range of 0V to 400V. The output waveforms of proposed fiber-optic sensor system has a good agreement with output waveforms of conductor current and voltage. Experimental results proved that the output of fiber-optic current sensor is not affected by the electric voltage applied to the fiber-optic voltage sensor, and also, that the output of fiber-optic voltage sensor is not affected by the electric current applied to the fiber-optic current sensor.

  • PDF

Parameters identification and their errors for AC motor drive systems using the single current sensor technique (단일전류센서를 이용한 교류전동기 구동에서 전동기 상수동정과 그 오차)

  • 신휘범
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.587-590
    • /
    • 2000
  • An estimation scheme is used for solving two practical problems of the single current sensor technique. To improve the effect of parameter uncertainties the method that identifies motor parameters for AC motor drive systems using the single current sensor technique is presented. And the parameter identification error and its cause atre examined. It gives good performances for identify in parameters and reconstructing phase currents.

  • PDF

Current - Fed Active AC Power Filter (전류형 능동 교류 전력필터)

  • Park, Min-Ho;Choe, Gyu-Ha;Lee, Keun-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.409-413
    • /
    • 1988
  • In this paper a control technique for active power filters is proposed which not only eliminates the harmonic current, but also controls the reactive power at the ac side of PWM inverter-induction motor drive system. Injecting the proposed PWM current enables the harmonic components of orders not greater than the pulse number per half-cycle to be removed completely. It also enables the input power factor to become unity. Theoretical investigations are performed to evaluate the performance of the proposed control technique.

  • PDF

A CRPWM Boost Type AC/DC Converter based on Modified Trapezoidal PWM (Modified Trapezoidal PWM을 베이스로 한 CRPWM Boost Type AC/DC Converter)

  • 권영원;노의철;김인동;김만고;전성즙;조철제;문성득
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.342-345
    • /
    • 1999
  • This paper describes a current regulated PWM boost type rectifier based on modified trapezoidal PWM. Each switch of a converter has no switching for one third period of a fundamental line current. Therefore, the switching loss of the proposed scheme is less than that of the hysteresis current controller. Operating principle is described and controller. Operating principle is described and simulations and experiments are carried out.

  • PDF

AC harmonic elimination and reactive power compensation by voltage-type active filter (전압형 능동필터에 의한 교류고조파제거와 무효전력보상)

  • 김한성;최규하;신우석;이제필
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.688-692
    • /
    • 1988
  • The active filter system for harmonic current compensation is presented in this paper. The active filter, composed of a three-phase voltage-type PWM inverter and the capacitor, compensates both the harmonic currents and the reactive power by injecting the PWM current to the ac line. This paper describes the principle of harmonic current compensation, the calculation circuits for the harmonic currents to be injected, the several compensation characteristics. Also the experimental results are shown to verify the theory proposed in this paper.

  • PDF

A Study on Power Factor Correction of CO2 Arc Welder Using Three Phase Switch Mode Converter (3상 AC/DC 스위치 모드 승압형 컨버터를 이용한 CO2 아크 용접기 역률개선에 관한 연구)

  • 이정훈;김재문;안정준;이상석;원충연;김세찬
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.149-153
    • /
    • 1998
  • In this paper A switched mode AC/DC three phase boost converter with high power factor and sinusoidal input current waveform is analyzed and simulated. The proposed converter retain high power factor and sinusoidal input current waveform even under electric arc welder load. It is shown that experimental result and simulation waveform yield a sinusoidal input current waveform at high power factor.

  • PDF

New Switching signal Pattern in AC Chopper (교류초퍼에서 새로운 스위칭 신호패턴)

  • Jang, Do-Hyun;Yeon, Jae-Eul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1267-1269
    • /
    • 2000
  • New switching signal pattern for four switches is proposed to prevent the shortage of PWM ac choppers. In the proposed technique, four signals to four power switches are generated without current transformer, while the conventional technique requires sensing the polarity of input voltage by voltage comparator and checking the direction of input current by the current transformer. The signal circuit built by the proposed technique is simple, and reduces also the switching loss.

  • PDF

Desk-Top Robot with Power Factor Correction (역률개선 회로를 적용한 Desk-Top Robot)

  • Chun, Kwang-Su;Kim, Hak-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.343-346
    • /
    • 2007
  • Recently, many nations have released standard such as EN61000-3-2 to impose a limit on the harmonic current to prevent distortion of AC line and to save energy. Also, the limit on the harmonic current makes use of a trade barrier. Therefore, Power factor correction must have been suitable for a limit on the harmonic current. This paper presents AC servo motor drive to have merits of high power factor for Desk-Top Robot.

  • PDF