Development of the CO2 Inverter Welding Controller for Compensation of Voltage Loss (전압손실 보상용 CO2 인버터 용접기 콘트롤라 개발)

  • Bae, Jong-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.4
    • /
    • pp.54-60
    • /
    • 2005
  • In a $CO_2$ inverter welding machine, stable arcs can be generated and a welding performance that is a goal of welding can be improved when stable electric power with a low voltage and a high current is supplied to a electrode that is the secondary part (output load terminal) and the base metal. For such a stable power supply, therefore, the AC arc welding machine, the thyristor welder, and the inverter welder have been developed in order according to development of the power electronics techniques. Up to now, the thyristor welding machine is still broadly used but the application volume is gradually reduced by development of the inverter welder. Because the welding performance of the inverter welder is very good and the weight and size of the welder is remarkably light and small. The final goal of this research is to develop the voltage loss compensator that is a drawback of the inverter welder and improve the welding performance using the developed compensator.

  • PDF

Oxygen matters: hypoxia as a pathogenic mechanism in rhinosinusitis

  • Cho, Hyung-Ju;Kim, Chang-Hoon
    • BMB Reports
    • /
    • v.51 no.2
    • /
    • pp.59-64
    • /
    • 2018
  • The airway epithelium is the first place, where a defense mechanism is initiated against environmental stimuli. Mucociliary transport (MCT), which is the defense mechanism of the airway and the role of airway epithelium as mechanical barriers are essential in innate immunity. To maintain normal physiologic function, normal oxygenation is critical for the production of energy for optimal cellular functions. Several pathologic conditions are associated with a decrease in oxygen tension in airway epithelium and chronic sinusitis is one of the airway diseases, which is associated with the hypoxic condition, a potent inflammatory stimulant. We have observed the overexpression of the hypoxia-inducible factor 1 (HIF-1), an essential factor for oxygen homeostasis, in the epithelium of sinus mucosa in sinusitis patients. In a series of previous reports, we have found hypoxia-induced mucus hyperproduction, especially by MUC5AC hyperproduction, disruption of epithelial barrier function by the production of VEGF, and down-regulation of junctional proteins such as ZO-1 and E-cadherin. Furthermore, hypoxia-induced inflammation by HMGB1 translocation into the cytoplasm results in the release of IL-8 through a ROS-dependent mechanism in upper airway epithelium. In this mini-review, we briefly introduce and summarize current progress in the pathogenesis of sinusitis related to hypoxia. The investigation of hypoxia-related pathophysiology in airway epithelium will suggest new insights on airway inflammatory diseases, such as rhinosinusitis for clinical application and drug development.

Direction for Development of Energy Regeneration Device for DC Electric Railway System (DC전철구간의 에너지회생장치 개발 방향)

  • Kim, Yong-Ki;Bae, Chang-Han;Han, Moon-Seob;Yang, Young-Chul;Jang, Su-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.804-808
    • /
    • 2007
  • when electric traction system used DC 1500V runs on decline of rail road track and slows down, Dc voltage goes beyond regular voltage. In this case extra power is forcibly wasted by resister because rectifier of substation and electric train including power converter and so on are out of order. This paper described a DC electric railway system, which can generate the excessive DC power form DC bus line to AC source in substation for traction system. The proposed regeneration inverter system for DC traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation. In addition, electric traction system products harmonic current and voltage distortion and reactive power because power converter is used so regeneration inverter normally runs such as active power filter(APF) for improving power quality. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three phase PWM inverters and composed of parallel inverters, output transformers, and an LCL filter.

  • PDF

A Study on the Wearing Phenomenon of Pantograph Slider for the SEOUL METRO Line 4 Rail Vehicles (4호선 전동차 판토그라프 주습판 마모현상에 관한 연구)

  • Kim, Young-Gyu;Yang, Yong-Joon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.51-56
    • /
    • 2007
  • Pantograph of the electric train is the important part receiving current by adhereing contact wire. Wearing rate of pantograph or contact wire is changed by the type of pantograph and material of adhering part. In special, the weather influences the relative wearing rate and wearing type of pantograph Slider and Contact wire with steep wearing in arc and life cycle of pantograph slider. Presently, the weather causes side-wearing and over-wearing of pantograph slide installed in electric train. So it is difficult to manage and operate the electric train. Although the quality of slide using in line4 vehicle was finished the test in line 2 vehicle experimentally, it has to apply after pantograph is installed in some electric trains and check the influence in it and contact wire. It is because line4 section is very different from line2 section. Experimental application is the sequence to certify the safety and abrasion resistance importantly by enlarging experimental application with increase of the experimental electric train. The lenth of line4 in Seoul Metro is 71.5[km]. It is long section. The line is mixed DC 1,500[V] section and AC 25,000[V] section. It has underground section of 41.5[km] and ground section of 30[km]. Ground section is about 42% and receives much influence in the rain during the rainy season. After experimental application we found that this pantograph slide has twice as much abrasion resistance despite a little deviation and found the occurrence probability of arc and side-wearing is decreased considerably.

  • PDF

The Effect of Process Parameter on the Symmetry of Nugget in Micro-resistance Series Spot Welding (정밀저항시리즈 점용접에서 너깃의 대칭성에 미치는 공정변수의 영향)

  • 조상명;김송미
    • Journal of Welding and Joining
    • /
    • v.19 no.6
    • /
    • pp.622-629
    • /
    • 2001
  • The aim of this experiment is to establish the method that obtains symmetrically two nuggets in microresistance series spot welding. The sheets of austenite stainless steel STS304 applied to various electronic parts were experimented by the inverter welding power source of polarity controllable type and by the twin head for left and right electrode force to be controlled separately. The experimental results were obtained as follows : 1) When series spot welding was carried out by DC 1 pulse as welding current with same electrode force at left and right, the asymmetry of nuggets was resulted from the larger nugget of the (-) pole because of the Peltier effect. The dynamic resistance of weld spot at left and right was appeared differently according to the growth of nuggets. 2) When AC 1 cycle by welding power source of polarity controllable type was applied, the nuggets were almost symmetrically formed. 3) In a twin head, if the electrode force of (-) pole was larger than that of (+) pole, the diameters of two nuggets became to same. It was confirmed that the dynamic resistance of (-) pole was decreased to the same level as it of (+) pole. 4) Although the forces of left and right electrode were same, and only DC 1 pulse was applied, symmetric nuggets were obtained if the conductivity of (+) pole was lower than it of (-) pole.

  • PDF

Characterization of YBCO do SQUID fabricated on sapphire substrate for biomagnetic applications (생체자기 응용을 위한 사파이어 기판 위에 제작된 YBCO dc SQUID 의 특성)

  • Lim, Hae-Ryong;Kim, In-Seon;Kim, Dong-Ho;Park, Yong-Ki;Park, Jong-Chul
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.155-159
    • /
    • 2000
  • YBCO step-edge dc SQUID magnetometers on sapphire substrates have been fabricated. CeO2 buffer layer and YBCO films were deposited in situ on the low angle (${\sim}$35$^{\circ}$) steps formed on the sapphire substrates. Typical 5-${\mu}$m-wide junction has R$_n$ of 5 ${\omega}$ and I$_c$ of 50 ${\mu}$A with large I$_c$R$_n$ product of 250 ${\mu}$V at 77K. According to applied bias current, depth of voltage modulation was changed and maximum voltage was measured 16 ${\mu}$V. Field noise of do SQUID was measured 100${\sim}$300 fT/${\surd}^{Hz}$ in the 1 $^{kHz}$, and about 1.5 pT/${\surd}^{Hz}$ in the 1/f region. For ac bias reversal method, field noise was decreased in the 1/f region. The QRS peak of magnetocardiogram was measured 50 pT in the magnetically shielded room.

  • PDF

Fabrication and Characteristic Tests of a 1 MVA Single Phase HTS Transformer with Concentrically Arranged Windings

  • Kim, S.H.;Kim, W.S.;Choi, K.D.;Joo, H.G.;Hong, G.W.;Han, J.H.;Lee, H.G.;Park, J.H.;Song, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.37-40
    • /
    • 2004
  • A 1 MV A single phase high temperature superconducting (HTS) transformer was manufactured and tested. The rated voltages of primary and secondary of the HTS transformer are 22.9 kV and 6.6 kV respectively. BSCCO-2223 HTS tape was used for HTS windings of 1 MV A HTS transformer. In order to reduce AC loss generated in the HTS winding, the type of concentric arrangement winding was adopted to a 1 MV A HTS transformer. Single HTS tape for primary windings and 4 parallel HTS tapes for secondary windings were used considering the each rated current of the HTS transformer. A core of HTS transformer was fabricated as a shell type core made of laminated silicon steel plate. And a GFRP cryostat with a room temperature bore was also manufactured. The characteristic tests of 1 MV A HTS transformer were performed such as no load test, short circuit test and several insulation tests at 65 K using sub-cooled liquid nitrogen. From the results of tests, the validity of design of HTS transformer was ascertained.

An Analysis on Fault Response Characteristics in Low Voltage DC Distribution System (저압직류 배전계통의 고장응답 특성 분석)

  • Noh, Chul-Ho;Gwon, Gi-Hyeon;Song, Jong-Il;Han, Joon;Oh, Yun-Sik;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.911-917
    • /
    • 2016
  • DC-based power system is paid attention as interests in energy efficiency and power quality are increased. However, standardization and researches for commercializing Low Voltage DC(LVDC) distribution system are still insufficient. Protection system, which is closely related with reliability, power quality, safety, and life expectancy of components in power system, is also included. This paper therefore analyzes fault response characteristics in LVDC distribution system as a preliminary study on protection schemes. A stepwise analysis on fault current from both AC/DC converter and DC/DC converter is performed and related expressions are derived. And then, modeling and simulation with various conditions are conducted by using ElectroMagnetic Transients Program (EMTP) to verify analysis results. Based on research results in the paper, direction for development of protection schemes for LVDC distribution system is suggested.

Development of Fault Detector for Series Arc Fault in Low Voltage DC Distribution System using Wavelet Singular Value Decomposition and State Diagram

  • Oh, Yun-Sik;Han, Joon;Gwon, Gi-Hyeon;Kim, Doo-Ung;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.766-776
    • /
    • 2015
  • It is well known that series arc faults in Low Voltage DC (LVDC) distribution system occur at unintended points of discontinuity within an electrical circuit. These faults can make circuit breakers not respond timely due to low fault current. It, therefore, is needed to detect the series fault for protecting circuits from electrical fires. This paper proposes a novel scheme to detect the series arc fault using Wavelet Singular Value Decomposition (WSVD) and state diagram. In this paper, the fault detector developed is designed by using three criterion factors based on the RMS value of Singular value of Approximation (SA), Sum of the absolute value of Detail (SD), and state diagram. LVDC distribution system including AC/DC and DC/DC converter is modeled to verify the proposed scheme using ElectroMagnetic Transient Program (EMTP) software. EMTP/MODELS is also utilized to implement the series arc model and WSVD. Simulation results according to various conditions clearly show the effectiveness of the proposed scheme.

Influence of Current capacity on AC Loss Characteristic in Single-layered Cylindrical High Temperature Superconductor (전류용량이 단층원통형 고온초전도도체의 교류손실 특성에 미치는 영향)

  • Ma, Y.H.;Li, Z.Y.;Ryu, K.;Lim, J.H.;Sohn, S.H.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.798-799
    • /
    • 2008
  • 초전도전력케이블에서 교류손실은 케이블의 효율을 저하시킬 뿐만 아니라 냉동기비용 증가로 인한 기존 케이블과의 가격경쟁에서 경제성을 저하시키는 주된 요인으로 작용하기 때문에 이의 상용화에 앞서 교류손실에 대한 정확한 규명이 되어야 한다. 그러나 다수본으로 구성되는 단층원통형의 고온초전도전력케이블에서 교류손실을 올바르게 평가하는 것은 테이프의 상이한 임계전류, 전압리드의 배열, 전류분포의 불균일성 및 인접한 테이프에 흐르는 전류위상 상이 등 복잡한 영향인자 때문에 매우 난해하다. 본 연구에서는 고온초전도전력케이블과 같은 단층원통형 고온초전도도체를 제작하여 실험적으로 교류손실 특성을 규명하였고, 또한 전류용량이 교류손실 특성에 미치는 영향을 실험적으로 조사하였다. 결과 원통형 고온초전도도체에서 교류손실 특성은 전류용량보다는 임계전류밀도에 더 의존하였다.

  • PDF