• 제목/요약/키워드: AC Current

검색결과 2,319건 처리시간 0.036초

Microstructural Change and Magnetic Properties of Nanocrystalline Fe-Si-B-Nb-Cu Based Alloys Containing Minor Elements

  • Nam, Seul-Ki;Moon, Sun-Gyu;Sohn, Keun Yong;Park, Won-Wook
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.327-332
    • /
    • 2014
  • The effect of minor element additions (Ca, Al) on microstructural change and magnetic properties of Fe-Nb-Cu-Si-B alloy has been investigated, in this paper. The Fe-Si-B-Nb-Cu(-Ca-Al) alloys were prepared by arc melting in argon gas atmosphere. The alloy ribbons were fabricated by melt-spinning, and heat-treated under a nitrogen atmosphere at $520-570^{\circ}C$ for 1 h. The soft magnetic properties of the ribbon core were analyzed using the AC B-H meter. A differential scanning calorimetry (DSC) was used to examine the crystallization behavior of the amorphous alloy ribbon. The microstructure was observed by X-ray diffraction (XRD), transmission electron microscope (TEM) and scanning electron microscope (SEM). The addition of Ca increased the electrical resistivity to reduce the eddy current loss. And the addition of Al decreased the intrinsic magnetocrystalline anisotropy $K_1$ resulting in the increased permeability. The reduction in the size of the ${\alpha}$-Fe precipitates was observed in the alloys containing of Ca and Al. Based on the results, it can be concluded that the additions of Ca and Al notably improved the soft magnetic properties such as permeability, coercivity and core loss in the Fe-Nb-Cu-Si-B base nanocrystalline alloys.

Z-원 승압인버터를 이용한 변압기 없는 DGS제어 (Transformerless DGS Control using a Z-source Boost Inverter)

  • 박영산
    • 한국정보통신학회논문지
    • /
    • 제10권9호
    • /
    • pp.1617-1624
    • /
    • 2006
  • 본 논문은 분산전원시스템(DGS)을 위 한 시스템 모델링, 수정된 SVPWM 적용 그리고 수동소자인 L과 C로 구성된 Z-원 인버터의 제어기에 대하여 기술하였다. 기존의 DC/DC 승압 컨버터나 변압기를 사용하지 않고 낮은 DC 입력을 상용 AC로 만들기 위해서 SVPWM의 영벡터 구간을 이용해 DC-링크단 전압을 승압하는데 이용하였다. 한 스위칭주기에 3개조의 스위칭소자 중에 2개조만 동시 도통되도록 하여 유효벡터의 손실 없이 승압이 가능하도록 하였다. 빠르고 오버슈트가 없는 전류응답과 낮은 정상상태 전압오차를 얻기 위해서 이산시간 슬라이딩모드 전류제어기와 강인한 서보기구 전압제어기를 설계하였다. 시뮬레이션을 통하여 제안된 알고리즘의 유용성을 확인하였다.

3-레벨 반브리지로 구성된 SSSC의 동특성 분석 (Dynamic Characteristic Analysis of 3-Level Half-bridge SSSC)

  • 박상호;하요철;백승택;김희중;한병문
    • 전력전자학회논문지
    • /
    • 제6권4호
    • /
    • pp.317-324
    • /
    • 2001
  • 본 논문에서는 3-레벨 반브리지 인버터로 구성된 SSSC를 제안하였다. 제안한 SSSC의 동적특성을 분석하기 위해서 1기 무한모선 전력계통에 SSSC응 연결한 것을 가정하고 EMTP 시뮬레이션을 수행하였고, 축소모형 실험으로 그 특성을 확인하였다. 3-레벨 SSSC는 한 상당 6개의 단상 풀브리지 인버터로 구성되었고, PWM모드로 동작한다. 3-레벨 SSSC는 전압 주입을 위한 연계 변압기가 필요하지 않고, 전력계통에서 요구되는 동작전압에 EK라 브리지의 수를 가감하여 용이하게 구성할 수 있다.

  • PDF

Control and Analysis of Vienna Rectifier Used as the Generator-Side Converter of PMSG-based Wind Power Generation Systems

  • Zhao, Hongyan;Zheng, Trillion Q.;Li, Yan;Du, Jifei;Shi, Pu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.212-221
    • /
    • 2017
  • Permanent-Magnet Synchronous Generators (PMSGs) are used widely in Wind Power Generation Systems (WPGSs), and the Vienna rectifier was recently proposed to be used as the generator-side converter to rectify the AC output voltage in PMSG-based WPGS. Compared to conventional six-switch two-level PWM (2L-PWM) converters, the Vienna rectifier has several advantages, such as higher efficiency, improved total harmonic distortion, etc. The motivation behind this paper is to verify the performance of direct-driven PMSG wind turbine system based-Vienna rectifier by using a simulated direct-driven PMSG WPGS. In addition, for the purpose of reducing the reactive power loss of PMSGs, this paper proposes an induced voltage sensing scheme which can make the stator current maintain accurate synchronization with the induced voltage. Meanwhile, considering the Neutral-Point Voltage (NPV) variation in the DC-side of the Vienna rectifier, a NPV balancing control strategy is added to the control system. In addition, both the effectiveness of the proposed method and the performance of the direct-driven PMSG based-Vienna rectifier are verified by simulation and experimental results.

Comparison of the fluid simulation with experimental data of excited Xe species density in PDP cell

  • Yang, Sung-Soo;Ko, Sang-Woo;Kim, Hyun-Chul;Mukherjee, Sudeshna;Lee, Jae-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.739-742
    • /
    • 2003
  • We have compared 2-D and 3-D fluid simulation results of alternating current plasma display panel (AC-PDP) cell with experimentally measured two kinds of excited Xe species $Xe^{\ast}(^{3}P_{1})$ and $Xe^{\ast}(^{3}P_{2})$ characteristics. Although direct experimental access and diagnostics of the discharge in a PDP cell is problematic due to the small cell size, some of experimental technologies have made it possible to diagnose the behavior of excited Xe species [1, 2]. The simulation shows the similar characteristics to the experimental results in the excited Xe species density distribution and the number of excited Xe atoms in anode and cathode region. In certain cases, we obtained the arch-shaped discharge path between two sustain electrodes due to the additional pulse applied to address electrode analogous to experiment. This long path discharge induced higher luminous and discharge efficiency compared to the standard case.

  • PDF

유전체장벽방전효과를 이용한 공해물질 제거 효율에 미치는 공간전하의 영향 분석 (Analysis of Effects of Space Charge in Removal efficiency of Pollutant using Dielectric Barrier Discharges)

  • 남석현;전승익;이동영;이준호;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1441-1443
    • /
    • 1998
  • In this work, the effects of space charge was analyzed in removal efficiency of pollutant using dielectric barrier discharges. In order to investigate effects of space charge, two dielectrics(XLPE and TR-XLPE) was chosen which are different in space charge distribution. The simultaneously measurement of space charge and discharge current was carried out in XLPE and TR-XLPE with air gap by Pulsed-Electro-Acoustic Method in ac. Also, the removal efficiency is measured by classical ozone generator(von Siemens 1875). From the experimental results, we knew that the space charge distribution affects the discharge patterns. The more space charge is in surface, the quickly discharge initiates and the magnitude of discharge is increased when polarity changes. And these affect the removal efficiency of pollutant.

  • PDF

가소제 혼합비에 따른 PAN/PVDF계 고분자 전해질의 이온 전도 특성 (Conductivity of PAN/PVDF based Polymer Electrolyte as a Function of Plasticizer Mixed Ratio)

  • 이재안;김종욱;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.261-264
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. This paper describes temperature dependence of conductivity, impedance spectroscopy, electrochemical properties of PAN/PVDF electrolytes as a function of a mixed ratio. PAN/PVDF based polymer electrolyte films were prepared by thermal gellification method of preweighed PAN/PVDF, plasticizer and Li salt. By adding PVDF and as a function of plasticizer mixed ratio to PAN-LiClO4 electrolyte, its conductivity was higher than that of PAN-$LiClO4_4$ electrolyte. The conductivity of PAN/PVDF electrolytes was $10^{-3}S/cm$. $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte shows the better conductivity of the others. Steady state current method and ac impedance used for the determination of transference numbers in PAN/PVDF electrolyte film. The transference number of $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte is 0.45.

  • PDF

무성방전의 중첩을 이용한 다중방전형 오존발생기의 오존생성수율 개선 (Improvement of Ozone Yield by a Multi-Discharge Type Ozonizer Using Super position of Silent Discharge Plasma)

  • 송현직;이동헌;오진훈;박성욱;서영택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.88-91
    • /
    • 2004
  • In order to improve ozone generation, we experimentally investigated the silent discharge plasma and ozone generation characteristics of a multi-discharge type ozonizer. Ozone in a multi-discharge type ozonizer is generated by superposition of a silent discharge plasma, which is simultaneously generated in separated discharge spaces. A multi-discharge type ozonizer is composed of three different kinds of superposed silent discharge type ozonizers, depending on the method of applying power to each electrode. We observed that the discharge period of the current pulse for a multi-discharge type ozonizer can be longer than that of silent discharge type ozonizer with two electrodes and one gap.Hence, ozone generation is improved up to 17185 ppm and 783 g/kwh for the superposed silent discharge type ozonizer for which an AC high voltages with a 180 phase difference were applied to the internal electrode and the external electrode, respectively, with the central electrode being ground

  • PDF

교류전압 인가 상태에서 저압 진공관의 방전현상 (Ion Transport and High Frequency Dielectric of the Hollandite Nax$(Ti_{8-x}Cr_x)O_{16}$)

  • 왕강;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.243-244
    • /
    • 2008
  • We experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and $SF_6$. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We a1so revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

염료감응형 태양전지용 $TiO_2$ 광전극의 전기화학적 특성 ($TiO_2$ Photoanode on Dye-Sensitized and Electrochemical Properties of Solar Cells)

  • 김은미;박경희;구할본;박복기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.253-254
    • /
    • 2008
  • The $TiO_2$ Pastes was prepared with the starting materials of $TiO_2$ (P-25), ethyl cellulose, a-terpineol and bis(2-ethylhexyl) phthalate, and this $TiO_2$ paste application for dye-sensitized solar cells (DSSCs) were investigated. In order to improved transparency of $TiO_2$ photoanode films, $TiO_2$ paste was changed ethyl cellulose and a-terpineol contents. The morphology of prepared $TiO_2$ films were investigated by field emission scanning electron microscopy (FE-SEM). The electrochemical properties of the thin films and the performance of DSSCs were measured by photovoltaic-current density and AC impedance. Energy conversion efficiency was obtained about 5.7% at ethyl cellulose and a-terpineol on best mixed ratio under illumination with AM 1.5 ($100mWcm^{-2}$)simulated sunlight.

  • PDF