• 제목/요약/키워드: AC BDV

검색결과 6건 처리시간 0.019초

XLPE 절연체에서의 열이력에 의한 전기, 물리적 특성 평가 (Estimation of Electrical & Physical Characteristics by Thermal History in XLPE Insulation)

  • 이상진;심성익;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 합동춘계학술대회 논문집 전기물성,응용부문
    • /
    • pp.183-184
    • /
    • 2008
  • The aim of this study is to find out the effects of thermal aging condition on dielectric strength and degree of crtstallinity of XLPE insulation. Thermal properties of XLPE insulation were investigated by DSC(differential scanning calorimetry) and dielectric strength were analyzed using AC BDV tester. Aging of XLPE samples were conducted through different four conditions. The degree of crtstallinity and AC BDV were changed by thermal history. From these results, it can be suggested that DSC and AC BDV test are suitable for diagnostic method of extra high voltage XLPE cable.

  • PDF

액체질소 중 열기포 형상 및 절연 특성 (Shape and Dielectric Strength of Thermal Bubbles in Liquid Nitrogen)

  • 백승명;김해종
    • 한국전기전자재료학회논문지
    • /
    • 제28권5호
    • /
    • pp.326-331
    • /
    • 2015
  • In this paper, we study the insulating properties of the liquid nitrogen(LN2) including the thermal bubbles. The shape of the thermal bubbles in accordance with the current change was observed in the 77 K and 65 K LN2. According to the temperature of liquid nitrogen, bubbles were generated differently. The round shape of the bubble is occurred in 77 K LN2. But the layer shape of bubble is occurred in 65 K LN2. When the bubbles present, the dielectric strength of liquid nitrogen is low. However, the breakdown patterns were different according to the electrode arrangement. AC breakdown voltage(BDV) was lower than the DC BDV due to the influence of bubbles. Therefore, the design of a high-voltage superconducting equipments should consider the bubbles.

과도한 인장력에 따른 해상풍력단지 해저케이블의 절연 특성 평가 (Evaluation of Insulation Characteristics of Submarine Cables in Offshore Wind Farm by Excessive Tension)

  • 이승원;최진욱;권익수;김동은;김해종
    • 한국전기전자재료학회논문지
    • /
    • 제37권3호
    • /
    • pp.286-291
    • /
    • 2024
  • Research on aged insulation of cables by stress is constantly being considered for reliable and stable power transmission of offshore wind farms. This study aimed to evaluate the insulation characteristic of aged XLPE (cross-linked polyethylene) insulation for application of offshore wind farms. In this study, The XLPE insulation of cable was set as various mechanical strains. The XLPE insulation is exposed to the mechanical stress below yield strain of 5%, 10%, and 20%. Aged samples were tested by using the method of AC BDV (alternative current breakdown voltage), tensile strength, elongation, and SEM (scanning electron microscope) to obtain insulation characteristics. The experimental results show that the dielectric breakdown of the sample with a strain 20% was 50% lower than the unaged sample; thereby, demonstrating that the mechanical strain that occurred in the submarine cables can weaken the insulation characteristics. Therefore, mechanical strain should be monitored when laying and operating submarine cables for offshore wind farms.

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

고온초전도 한류기의 절연설계를 위한 과냉각 액체질소의 절연내력 특성 (Dielectric Characteristics of Subcooled $LN_2$ for Insulation Design of HTS Fault Current Limiters)

  • 백승명;정종만;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.46-50
    • /
    • 2003
  • In the dielectric insulation design of any high temperature superconducting (HTS) apparatus as well as HTS fault current limiter in the electrical power systems, the breakdown characteristics of cryogenic coolants such as liquid nitrogen ($LN_2$) are an important factor of the insulating engineering. Previous reports concerned with the breakdown characteristics of liquid nitrogen have pointed out that bubbles and gaseous nitrogen have a treat influence on their breakdown phenomena, However, useful data for practical insulation design of HTS fault CUITent limiter operating at subcooled L$N_2$ have not been obtained enough. Therefore, this paper presents an experimental investigate of breakdown phenomena in liquid nitrogen under AC voltage, And, we observed the breakdown voltage (BDV) of liquid nitrogen with lowering temperature. The Weibull plots of the breakdown voltage of subcooled $LN_2$ for the needle-plane electrode with d= 10 mm are studied, The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated, The relationship between the AC breakdown characteristics and the temperature were clarified.

$SF_6$ 가스중 PET Film의 절연특성 (Insulated Characteristics of PET Film under $SF_6$)

  • 김정달;정장근;주성철;이덕진;박재윤;이용길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2120-2122
    • /
    • 1999
  • $SF_6$ gas has been widely used the gas insulated transmission line, gas insulated transformer and gas insulated substation and Polyester film used as the turn insulation with other material. $SF_6$ gas has been actively studied in domestic and foreign countries. In general, when dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents the insulation strength of turn insulation of $SF_6$-PET film studied under application of AC voltage, constitute of the plane to plane with PET Film. The results obtained in experimental are summarized that Partial Discharge Initial Voltage(PDIV) of turn insulation depend on gas pressure, but Breakdown Voltage(BDV) did not depend on gas pressure.

  • PDF