• 제목/요약/키워드: AC 전기장

검색결과 95건 처리시간 0.024초

주파수 의존성에 따른 고분자 LED의 유전 분산 거동에 관한 연구 (AC dielectric response of poly(p-phenylenevinylene) light emitting devices)

  • 이철의;김세헌;장재원;김상우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2000
  • AC impedance measurements on poly-p-phenylenevinylene (PPV) LEDs in the frequency range between 10 Hz and 10$\^$6/ Hz were carried out. The complex-plane impedance spectra indicate that PPV devices can be represented by equivalent circuits that corresponds to the bulk and interfacial regions at high and low frequencies, respectively. As a result of complex impedance analysis through the separation of bulk and interfacial region impedances, increase of forward bias in Al/PPV/ITO devices gave rise to relative decrease of the interfacial region impedance. Above the electric field of 10$\^$6/ V/cm the PPV device showed a space charge limited current (SCLC) conduction. The dependence of the transport mechanism and dielectric properties on the applied bias voltage is discussed.

  • PDF

SMART Link를 이용한 전력계통 최적화 운영 (Power network Optimal Operation using SMART Link)

  • 김찬기;이정석;곽노홍;장재원;원영진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.40-43
    • /
    • 2008
  • 본 논문은 AC계통에 DC계통을 중첩하여 계통의 안정도를 극대화 하는 새로운 방안(본 논문에서는 SMART Link로 명명)을 제시하였다. 제안된 방식은 경계적인 관점에서 기존의 송전선로를 이용하는 방법을 제시하였고, 대규모 환상망에서 발생하는 고장전류를 저감하는 방법을 논하였다. 그리고, SMART Link의 문제점과 이에 대한 해결 방식을 제시하여 실제 적용 가능한 계통망을 제시하였다.

  • PDF

폴리에틸렌으로 피복된 전선을 통해 위로 전파하는 화염에 대한 교류전기장 효과에 대한 실험적 연구 (Experimental Study on Effect of AC Electric Field on Upwardly Spreading Flame over Polyethylene insulated Electrical Wire)

  • 임승재;김민국;박정;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.363-365
    • /
    • 2014
  • An experimental study on effect of AC electric field on upwardly spreading flame over electrical wire, which is insulated by Polyethylene(PE), was conducted. The result showed that upwardly spreading flame leaned toward unburned side with angle of inclination. With applied electric field, size of upwardly spreading flame increased significantly. Flame spread rate showed various trends with inclination, applied voltage and frequency.

  • PDF

평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발 (Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor)

  • 강전홍;류제천;이상화;김규태;김명수;한상옥;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권9호
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.

홀로그래픽 고분자 분산 액정을 이용한 홀로그램 이중 초점 렌즈 제작 (Fabrication of bifocal holographic lenses by holographic polymer dispersed liquid crystal film)

  • 이정훈;성기영;이상조;김기현;조영걸;곽종훈;송재봉;이윤우
    • 한국광학회지
    • /
    • 제14권2호
    • /
    • pp.109-115
    • /
    • 2003
  • 다기능성 아크릴레이트 단량체와 네마틱 액정 등을 혼합한 홀로그래픽 고분자 분산 액정 박막을 제작하고 액정의 농도와 피부에서 인가한 교류 전기장 등에 대한 실시간 회절효율을 측정하였다. WPDLC 박막에 기록된 홀로그램은 적절한 교류 전기장의 on/off에 의해 가역적으로 소거와 재생이 가능함을 보였다. 이러한 전기광학 특성을 이용하여 30 cm와 40 cm의 이중초점을 갖는 홀로그램 렌즈를 제작하였다.

전력케이블에서 개폐충격파를 이용한 부분방전 측정 (Partial Discharge Measurement in Power Cables using Switching Impulse Voltages)

  • 이전선;장은;구자윤;김정태;조연옥;김상준;송일근;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.382-384
    • /
    • 1997
  • On-site partial discharge test by use of AC voltage has been considered not to be appropriate for the extruded power cable due to their large capacitance depending on their lengths. Therefore, it is proposed, in this work, to use switching impulse voltage of which the front time is set from 1ms to 10ms. This newly proposed method enables us to simulate the 1/4 period of power frequency at 60 Hz and to obtain similar effect of AC voltage test. Our tentative results show that 51 voltage is proved to be an alternative method, replacing AC voltage, by which partial discharge was well produced from the artificial defects integrated in 22.9kV distribution power cables.

  • PDF

22.9 kV 배전급 초전도케이블의 DC/AC 특성에 관한 연구 (A Study of DC/AC Characteristics on 22.9 kV distribution class HTS-cable)

  • 마용호;류경우;손송호;임지현;황시돌;최하옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.287-287
    • /
    • 2008
  • HTS-케이블은 구리도체 대신 고온초전도도체를 사용하여 저항이 0이 되는 초전도현상을 이용하여 대용량 전력수송이 가능한 전력케이블로서 대도시의 전력부하 집중문제를 해결할 수 있는 환경 친화적 전력케이블이다. 최근 고온초전도선재의 고임계전류밀도화 및 장척화에 힘입어 HTS-케이블의 실용화를 목표로 경제성이 있는 전력케이블을 개발하려는 움직임뿐만 아니라 실증시험 등 활발한 연구가 진행 중이다. 그러나 초전도전력케이블에서 발생되는 교류손실은 케이블의 효율을 저하시킬 뿐만 아니라 냉동기비용 증가로 인한 기존 케이블과의 가격경쟁에서 경제성을 저하시키는 주된 요인으로 작용하기 때문에 이의 상용화에 앞서 교류손실에 대한 정확한 규명이 되어야 하며 또한 실계통 투입 시 중요한 선로임피던스에 대한 정확한 규명도 필요하다. 본 논문에서는 실제 한전 주관으로 고창시험장에 설치된 배전급 22.9 kV, 100 m, 50 MVA급 3 상 HTS-케이블에 대한 통전특성을 규명하기 위하여 먼저 HTS-케이블의 DC 통전특성을 조사하였다. 또한 3상평형운전상태에서 AC 통전특성(인덕턴스 및 교류손실)을 실험적으로 조사하였으며 5m-케이블에서 측정된 결과와 비교 검토하였다.

  • PDF

폴리에틸렌 피복전선 화염의 전파에 영향을 미치는 직류전기장의 인가 효과에 관한 실험적 연구 (Effect of Applied DC Electric Fields in Flame Spread over Polyethylene-Coated Electrical Wire)

  • 진영규;김민국;박정;정석호;윤진한;길상인
    • 대한기계학회논문집B
    • /
    • 제35권3호
    • /
    • pp.321-330
    • /
    • 2011
  • 본 연구는 전선화염의 전파특성에 직류전기장이 미치는 영향에 대한 실험적 연구이다. 화염전파는 은 0에서 ${\pm}7kV$ 범위의 음극과 양극의 전기장을 인가하여 실험되어졌다. 본 연구를 통해 앞선 전선화염 전파에 영향을 미치는 교류전기장 효과에 관한 연구결과와 비교하여 관찰된 다양한 화염 모양 변화의 원인을 알아보고, 화염 전파 속도의 가속특성에 대해서도 논의하고자 한다. 직류전기장의 인가가 전선화염에 미치는 영향은 크지 않지만 이온풍 효과에 따른 미미한 영향은 존재하며, 이것은 온도 균형 메커니즘과 연료 증발기체 분사 효과로 설명 될 수 있다.

저주파 자기장 차폐를 위한 자기차폐실 설계 (Design of MSR for Magnetic Field Shielding of Low Frequency)

  • 최학윤
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.154-159
    • /
    • 2010
  • 본 논문에서는 0.1[Hz]에서 60[Hz]의 저주파 자기장을 차폐할 수 있는 경량의 자기차폐실을 설계하고, 차폐실을 제작하여 차폐율을 측정하였다. 자기차폐실의 크기는 산업용 측정기기가 들어갈 수 있는 3.0[m](W)$\times$ 3.0[m](L)$\times$3.0[m](H)로 하였으며, 투자율이 높은 자성체의 직류차폐와 교류차폐특성, 도전성물질의 와전류에 의한 차폐율을 계산하였고, 설계된 결과로부터 차폐실의 구조 값을 구하였다. 설계된 차폐실의 타당성을 검토하기 위하여 저주파 차폐실을 제작하고 차폐율을 측정하여 계산값과 비교하였다. 측정결과는 0.1[Hz]에서 5배 이상의 차폐율을 만족하였고, 60[Hz]에서는 86배였다. 따라서 본 논문에서 제작한 자기차폐실은 저주파 자기차폐실로 사용할 수 있을 것으로 생각된다.

전기장 왜란을 이용한 비접촉 스마트 TV 제스처 인식 알고리즘 (Non-Contact Gesture Recognition Algorithm for Smart TV Using Electric Field Disturbance)

  • 조정재;김영철
    • 한국멀티미디어학회논문지
    • /
    • 제17권2호
    • /
    • pp.124-131
    • /
    • 2014
  • 본 논문에서는 4-채널 전위계 센서의 배열을 이용한 비접촉 제스처 인식 알고리즘을 제안한다. 주변의 전기장 변화에 민감한 전위계 센서를 스마트기기의 제스처인식에 활용하기 위해서 실내 환경에서 극저주파 대역 EMI(Electro Magnetic Interference) 및 PLN(Power Line Noise) 영향을 최소화하였다. AC 형태의 입력 데이터 값에 10Hz LPF(Low Pass Filter) 및 H/W 샘플링 속도를 고려한 최대 버퍼 값 추출 알고리즘을 적용하여 선형적인 DC 형태의 데이터로 변형한다. 추가적으로 칼만 필터를 적용함으로써 노이즈를 최소화하며, 센서간의 배열을 고려한 데이터 차분 과정을 통해 목표물의 2차원적 움직임 정보를 추출한다. 추출된 데이터 값과 peak 값의 시차정보를 이용하여 DTW(Dynamic Time Warping) 제스처 인식 및 보정 알고리즘을 구현하였으며, 다섯가지 동작 시나리오 테스트 결과 95% 이상의 높은 인식률을 보였다.