• Title/Summary/Keyword: AC알고리즘

Search Result 226, Processing Time 0.022 seconds

Fault Diagnosis for 3-Phase Diode Rectifier using Harmonic Ripples of DC Link Voltage (직류단 전압의 고조파 맥동 검출을 이용한 3상 다이오드 정류기의 고장 진단)

  • Park, Je-Wook;Baek, Seong-Won;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.457-465
    • /
    • 2011
  • The fault analysis and detecting algorithm for a 3 phase diode rectifier is proposed. The 3 phase dioderectifier is used for the AC power rectifier of the PWM inverter. The input power or diode faults cause theripples of the DC voltage, degradation of the control performance and life shortening of the DC link capacitor.In this paper, the ripple of the DC voltage is mathematically analyzed for the earth fault of input power andopen circuit fault of the diode, respectively. The fault detection and type of fault can be obtained by comparingthe average DC voltage and the instant DC voltage which is sampled with 6 times of grid frequency. Theproposed method can be easily applicable and doesn't require additional circuit. The experimental and simulationresults are presented to verify the validity of the proposed method.

Fuzzy-PID Gain Scheduling Algorithm of Resistive Welder for Electronic Parts (전자부품용 저항용접기의 퍼지-PID 이득조정 알고리즘)

  • Park, Myung-Kwan;Lee, Jong-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.114-116
    • /
    • 2004
  • The temperature profile control issue in the resistive welder for the electronic parts is discussed. The average current of the welder tip depends on the phase(on-time) of the AC power and the tip temperature maintains or increases/decreases depending on the integral of the current square and heat loss, The basic PID control algorithm with thermo-couple feedback is difficult to track the temperature profile for various parts and optimal gain changes much. So constant gain PID algorithm is not enough to cover various electronic parts welding and a Fuzzy-PID automatic gain tuning algorithm is devised and added to conventional PID algorithm and this hybrid control architecture is implemented and the experimental results are shown.

  • PDF

A novel anti-islanding method using Goertzel Algorithm (Goertzel 알고리즘을 이용한 새로운 단독운전 방지 기법)

  • Won, Dong-Jo;Kim, Jae-Hyung;Kim, Jun-Gu;Won, Chung-Yuen;Lee, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.299-301
    • /
    • 2009
  • In this paper, a novel anti-islanding method of DC-AC single phase inverter is proposed. The inverter injects a little harmonic current with the output current of a PCS(Power Conditioning System). When the islanding condition is occurred, the voltage harmonic components appear on the output voltage of the PCS due to the injection of a little harmonic current. So, the PCS detects the voltage harmonic components using the Goertzel algorithm, and then the PCS decides that the islanding condition is occurred. When the PCS recognizes the islanding condition, the PCS are stopped. The proposed a novel anti-islanding method is analyzed, and its validity is proven through simulation.

  • PDF

The Inverter Control Method Using The Voltage Sag Compensation algorithm (순간전압강하 보상 알고리즘을 이용한 인버터 제어에 관한 연구)

  • Yun, Hong-Min;Bae, Jin-Yong;Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.62-67
    • /
    • 2012
  • In this paper general purpose voltage source inverter drives are equipped with an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag control algorithm, experimental results are presented.

Digital Firing Control for Thyristor Converter (사이리스터 디지털 점호제어)

  • Kim Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.584-591
    • /
    • 2004
  • The conventional analog-based firing circuit can be implemented by comparing a linearly decreasing periodic sawtooth waveform synchronized to the ac supply, with a control signal corresponding to the desired converter delay angle. This circuit requires a large number of passive components (resistance and capacitor) and careful adjustment of the synchronization circuity. In this paper a novel firing circuit is proposed for thyristor switch. The proposed circuit is implemented by using digital components(FPGA, A/D, and DSP etc.) on the basis of the analog cosine method.

A new Driving Algorithm Design and Implementation for High Efficiency and High Image Quality in PDP (PDP 고효율 고화질 구동 알고리즘 설계 및 FPGA 구현)

  • Cha, Soo-Ik;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.152-154
    • /
    • 2005
  • This paper proposes the new subfield method to erase reverse gray levels and low gray level contour in AC plasma display panel(PDP). In the conventional method, it is supposed that output luminance levels of a PDP increase regularly. But actual output luminance levels of a PDP increase irregularly. Therefore, conventional methods are unable to effectively reduce low gray-level contours and reverse gray levels. Accordingly, a new subfield method is applied to improve the low gray-level expression in PDP. Conclusively this paper clear proof that a new subfield method can suppress low gray-level contours and reverse gray levels more effectively than conventional methods.

  • PDF

Development of a Low-Cost Motion Cheir for Rollercoaster Simulation (롤러코스터 운동감 구현을 위한 보급형 모션의자 개발)

  • 서정아;정무진;신영기
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2002.05a
    • /
    • pp.115-121
    • /
    • 2002
  • PC 및 게임 소프트웨어의 급격한 발달로 가상현실 구현에 필요한 그래픽 환경은 성숙단계에 진입하였다. 현재 국내에서 개발되는 게임 소프트웨어는 PC사용자를 겨냥한 제품이 대부분이다. 토요일 휴무제의 도입에 따른 문화 콘텐츠 시장의 확대, 가족이 즐길 수 있는 테마 공원의 성장성 등을 고려할 때 기존의 PC 게임과 차별화 되는 운동감을 포함한 가상현실 게임 제품의 개발이 요망된다. 잘 알려진 6자유도 운동 시뮬레이션 방식인 Stewart 방식은 구현 가격이 고가이고 운동범위가 작아 게임용으로 상용화하기 어렵다. 본 연구에서는 2대의 AC 서보모터를 이용하여 roll과 pitch의 2자유도만 구현하나, 각 축으로 자유로운 회전이 가능하여 탑승자의 스릴감을 향상시킬 수 있는 저가형 운동의자를 개발하였다. 2 자유도로 회전하는 외부와 차단된 캐빈 내부에는 40인치 스크린과 프로젝터가 설치되어 롤러코스터 게임의 몰입감을 향상시켰다. 롤러코스터 가상현실을 대상으로 운동감을 극대화하기 위한 워시아웃 (washout) 필터의 설계 알고리즘이 제시된다. 탑승자들의 감성 평가를 객관화하기 위한 데이터 베이스 구축방안이 서술된다

  • PDF

Robust Speed Control of AC Permanent Magnet Synchronous Motor using RBF Neural Network (RBF 신경회로망을 이용한 교류 동기 모터의 강인 속도 제어)

  • 김은태;이성열
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.4
    • /
    • pp.243-250
    • /
    • 2003
  • In this paper, the speed controller of permanent-magnet synchronous motor (PMSM) using the RBF neural (NN) disturbance observer is proposed. The suggested controller is designed using the input-output feedback linearization technique for the nominal model of PMSM and incorporates the RBF NN disturbance observer to compensate for the system uncertainties. Because the RBF NN disturbance observer which estimates the variation of a system parameter and a load torque is employed, the proposed algorithm is robust against the uncertainties of the system. Finally, the computer simulation is carried out to verify the effectiveness of the proposed method.

Design of Fuzzy Logic Controller of HVDC using an Adaptive Evolutionary Algorithm (적응진화 알고리즘을 이용한 초고압 직류계통의 퍼지제어기 설계)

  • Choe, Jae-Gon;Hwang, Gi-Hyeon;Park, Jun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.5
    • /
    • pp.205-211
    • /
    • 2000
  • This paper presents an optimal design method for fuzzy logic controller (FLC) of HVDC using an Adaptive Evolutionary Algorithm(AEA). We have proposed the AEA which uses a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner in order to take merits of two different evolutionary algorithms. The AEA is used for tuning fuzzy membership functions and scaling constants. Simulation results show that disturbances are well damped and the dynamic performances of FLC have better responses than those of PD controller when AC system load changes suddenly.

  • PDF

Optimal Placement of Measurements using Genetic Algorithms for Harmonic State Estimation (고조파 상태 추정에 있어서 유전 알고리즘을 이용한 최적 측정위치 선정)

  • Chung, H.H.;Wang, Y.P.;Lee, J.P.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.298-300
    • /
    • 2002
  • The design of a measurement system to perform Harmonic State Estimation (HSE) is a very complex problem. In particular, the number of available harmonic instruments(Continuous Harmonic Analysis in Real Time : CHART) is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents a new HSE algorithm which is based on an optimal placement of measurement points using Genetic Algorithms (GAs). This HSE has been applied to the New Zealand AC Power System for the validation of the new HSE algorithm. The study results have indicated an economical and effective method for optimal placement of measurement points using GAs in the HSE.

  • PDF