• 제목/요약/키워드: AC/DC conversion

검색결과 244건 처리시간 0.023초

PWM컨버터를 적용한 경전철 전력공급시스템에 관한 연구 (A Study on DC Traction Power Supply System Using PWM Converter)

  • 김주락;박창릉;박기준;김주욱
    • 한국전기전자재료학회논문지
    • /
    • 제29권4호
    • /
    • pp.250-254
    • /
    • 2016
  • Currently, power conversion system which converts AC to DC Power is applied in domestic urban railway. The diode rectifier is used in most of them. However the diode rectifier can not control the output voltage and can not regenerate power as well. On the other hand, PWM (pulse width modulation) converter using IGBT (isolated gate bipolar transistor) can control output voltage, allowing it to reduce the output voltage drop. Moreover the Bi-directional conduction regenerates power which does not require additional device for power regeneration control. This paper compared the simulation results for the DC power supply system on both the diode rectifier and the PWM converter. Under the same load condition, simulation circuit for each power supply system was constructed with the PSIM (performance simulation and modeling tool) software. The load condition was set according to the resistance value of the currently operating impedance of light rail line, and the line impedance was set according to the distance of each substations. The train was set using a passive resistor. PI (proportional integral) controller was applied to regulate the output voltage. PSIM simulation was conducted to verify that the PWM Converter was more efficient than the diode rectifier in DC Traction power supply system.

소프트 스위칭 3상 단일 스위치 승압형 컨버터 (Soft Switched Three-Phase Single Switch Boost-Type Converter)

  • 문상필;전찬욱;박성우;김대웅;김영문;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1166-1168
    • /
    • 2003
  • In most power electronic applications, the AC power input provided by the electronic utility needs to first converted to a DC voltage. Such conversion is accomplished by a diode rectifier due to its circuit simplicity and low cost. However, since diode rectifiers have some intrinsic problems such as low power factor and high harmonic distortion, a wide use of such rectifiers may cause noises, malfunction and heat damage in both electrical power systems and electrical machinery systems. This paper proposes soft switched three-phase single switch boost-type converter. The proposed circuit can perform Zero Voltage Switched(ZVS) without using any current and voltage sensors. For this circuit, both simulation and experiments have been performed. The results not only confirmed the ZVS but also indicated that, compared to the conventional hard switched converter, the prosed circuit can improve the efficiency as much as 1.7 to 4.7[%] while keeping the same high power factor and small harmonic distortion in their AC input.

  • PDF

고역률 PWM CONVERTER를 적용한 UPS (PWM Converter with Unity Power Factor for UPS systems)

  • 이우철;서인영;이범희;서동휘;권성곤;김성우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.753-755
    • /
    • 1993
  • Full Bridge Diode Rectification and Phase Controlled SCR Rectification are the most widely used methods of power conversion($AC{\rightarrow}DC$) in Power Electronic products such as UPS systems. But using these types of converters can lead to the following problems. First, they generate harmonics on the AC input side, which can cause interference in other equipment connected to the same commercial power line. Second, they deteriorate the power factor so that the input power capacity or the equipment becomes larger than the actual rated output capacity. As a means to overcome these problems an IGBT type PWM Converter, which applies a current control algorithm, is proposed. In this paper the enhancement of the converter performance is shown through simulation.

  • PDF

전류주입에 의한 전기추진시스템의 고조파 저감 (Harmonic Reduction of Electric Propulsion System by Current Injection)

  • 김종수;한원희;서동환
    • 해양환경안전학회지
    • /
    • 제18권4호
    • /
    • pp.360-364
    • /
    • 2012
  • 전기추진시스템 분야에서 AC/DC 컨버터는 상대적으로 간단한 다이오드 소자를 이용하는 정류기가 가장 널리 사용되고 있으며 이 정류기는 입력 전류에 큰 고조파를 포함하고 있어서 고조파 저감을 위한 많은 연구가 진행되고 있다. 본 연구에서 제안된 방식은 다이오드 정류기의 출력 전류를 정류기와 추진전동기 입력측에 주입하여 정류기와 추진전동기 입력 전류에 포함되는 고조파 성분을 줄이고 또한, 와이-델타 변압기를 정류기 및 추진전동기 입력회로에 설치되는 전류주입장치의 분배회로에 사용하여 주입전류와 전원 및 부하를 서로 절연함으로써 전류파형 개선과 전기적 안전성을 확보하였다. 제안한 방법을 현재 사용 중인 전기추진선박에서 적용하여 시뮬레이션 하였으며 기존의 전력변환장치와 비교하여 그 타당성을 입증하였다.

High Power Factor Three Phase Rectifier for High Power Density AC/DC Conversion Applications

  • Cho, J.G.;Jeong, C.Y.;Baek, J.W.;Song, D.I.;Yoo, D.W.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.648-653
    • /
    • 1998
  • The conventional three-phase rectifier with bulky LC output filter has been widely used in the industry because of its distinctive advantages over the active power factor correction rectifier such as simple circuit, high reliability, and low cost. Over than 0.9 power factor can be achieved, which is acceptable in most of industry applications. This rectifier, however, is not easy to use for high power density applications since the LC filter is bulky and heavy. To solve this problem, a new simple rectifier is presented in this paper. By eliminating the bulky LC filter from the conventional diode rectifier without losing most of the advantages of the conventional rectifier, very high power density power conversion with high power factor can be achieved. Operation principle and design considerations are illustrated and verified by Pspice simulation and experimental results from a prototype of 3.3 kW rectifier followed by 100KHz zero voltage switching full bridge PWM converter

  • PDF

Stability and Performance Investigations of Model Predictive Controlled Active-Front-End (AFE) Rectifiers for Energy Storage Systems

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.202-215
    • /
    • 2015
  • This paper investigates the stability and performance of model predictive controlled active-front-end (AFE) rectifiers for energy storage systems, which has been increasingly applied in power distribution sectors and in renewable energy sources to ensure an uninterruptable power supply. The model predictive control (MPC) algorithm utilizes the discrete behavior of power converters to determine appropriate switching states by defining a cost function. The stability of the MPC algorithm is analyzed with the discrete z-domain response and the nonlinear simulation model. The results confirms that the control method of the active-front-end (AFE) rectifier is stable, and that is operates with an infinite gain margin and a very fast dynamic response. Moreover, the performance of the MPC controlled AFE rectifier is verified with a 3.0 kW experimental system. This shows that the MPC controlled AFE rectifier operates with a unity power factor, an acceptable THD (4.0 %) level for the input current and a very low DC voltage ripple. Finally, an efficiency comparison is performed between the MPC and the VOC-based PWM controllers for AFE rectifiers. This comparison demonstrates the effectiveness of the MPC controller.

A Novel Simulation Scheme for Grid Connected Photovoltaic Generation Systems

  • Park, Monwon;Kim, Bong-Tae;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.169-174
    • /
    • 2001
  • A novel simulation scheme of transient phenomenon for the photovoltaic (PV) generation system under the real weather conditions has been proposed in this paper. A grid connected PV array is simulated using PSCAD/EMTDC. The transient changes of the output current of PV array under the real weather conditions is described and the output current of DC/AC converter flowing through the utility power network is also analyzed with the PWM switching width. Moreover, the MPPT control of PV generation system is combined to the system during the simulation for the comparison purposes of the control schemes. The outcome of the simulation demonstrates the effectiveness of the proposed simulation scheme. The result shows that the cost effective verifying for the efficiency or availability and stability of PV generation systems and the comparison research of various control schemes like MPPT under the same real whether conditions are eventually possible.

  • PDF

계통연계 태양광 발전시스템의 운전특성분석 (An Analysis of the Operation Characteristics of a Grid-Connected Photovoltaic Power Generation System)

  • 황인호;정승주;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.1945-1947
    • /
    • 1997
  • In this paper, a characteristics analysis of the grid-connected photovoltaic power generation system which uses the simulation method of PV array is reported. The control method of DC/AC power conversion were suggested to establish the basic application technology of photovoltaic systems. The results of the demonstration test of a 3kW grid-connected PV system show that the system utilization rate is 17.6% and the system efficiency is 8.9%.

  • PDF

Multiple Buck-Chopper using Partial Resonant Switching

  • Mun Sang-Pil;Suh Ki-Young;Lee Hyun-Woo;Chun Jung-Ham
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.189-192
    • /
    • 2001
  • This paper proposed that an AC-DC converter system using multiple buck-chopper operates with four choppers connecting to a number of parallel circuits. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative results on computer are included to confirm the validity of the analytical results. The partial resonant circuit makes use of an inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in a partial resonant circuit makes charging energy regenerated at input power source for resonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

소규모 주택용 태양광 발전시스템의 운전 특성 (The operating characteristics of a small-scale residential PV power system)

  • 안교상;임희천;강병삼;황인호;김신섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1284-1286
    • /
    • 2001
  • In this paper, the operating characteristics of a 3 kW class grid-interactive photovoltaic(PV) power system was analysed from January 1998 to December 2000. The construction of the PV system includes a DC/AC inverter for grid connection, PV module, and data Monitoring & Acquisition system. The major results of the field test of the 3 kW class grid-interactive PV system showed that the system utilization rate was 13.83% the conversion efficiency of the inverter was 88% at an over half load, and the PV system generated the electricity more then 300 kWh per month.

  • PDF