• Title/Summary/Keyword: ABSORB

Search Result 884, Processing Time 0.027 seconds

Axial Impact Collapse Analysis on Front-End Side Members of Vehicles by FEM (FEM에 의한 차량전면부 사이드부재의 축방향 충격압궤 해석)

  • Cha Cheon-Seok;Chung Jin-Oh;Yang In-Young
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2003
  • The front-end side members of vehicles(spot welded hat and double hat shaped section members) absorb most of the impact energy in a case of front-end collision. In this paper, specimens with various spot weld pitches have been tested with a high impact velocity of 7.19m/sec(impact energy of 1034J). The axial impact collapse simulation on the sections has been carried out to review the collapse characteristics of these sections, using an explicit finite element code, LS-DYNA3D. Comparing the results with experiments, the simulation has been verified; the energy absorbing capacity is analyzed and an analysis method is suggested to obtain exact collapse loads and deformation collapse modes.

The singulation study of $\mu$-BGA(Ball Grid Array) board using a pulsed Nd:YAG laser (펄스 Nd:YAG 레이저를 이용한 $\mu$-BGA 기판의 개별칩 분리 연구)

  • Baek, Kwang-Yeol;Lee, Kyoung-Cheol;Lee, Choen
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.524-527
    • /
    • 2000
  • In this paper, we have studied minimization of the burr which occurred after $\mu$-BGA(ball grid array) singulation process, singulation of the multilayer with a pulsed Nd:YAG(266, 532 nm) laser is used to cut the metal layer which doesn't well absorb laser beam. Especially, the photoresist and $N_2$blowing is effective to minimize of the surface demage and burr. In this experiment, the $N_2$ blowing reduces a laser energy loss by debris and suppress a surface oxidation. The SEM(scanning electron microscopes) and non-contact 3D inspector are used to measure cutting line-width and surface demage. The $\mu$-BGA singulation threshold energy is 75.0 J/cm$^2$at 30 ${\mu}{\textrm}{m}$/s scan speed.

  • PDF

Iodine doping effect of $\sigma$ -conjugate poly(methyl-phenylsilene). ($\sigma$-공액 고분자 poly(methyl-phenylsilyene)의 요오드 도핑효과 연구)

  • ;;S. Nespurek
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.145-148
    • /
    • 2000
  • In contrast to the $\pi$ -conjugated polymers which typically absorb light only in the visible spectral region, the $\sigma$-conjugated polymers can be used as efficient material absorbing light in the UV region. In this work, the electronic and optical properties of I$_2$-doped $\sigma$ -conjugated poly (methyl-phenylsilylene) (PMPSi) polymer were investigated. DC conductivity up to 1.2$\times$10$^{-4}$ S/cm was obtained by I$_2$-doping. In UV/Vis absorbance spectrum, a new peak was observed near 370 nm, which was explained by polaron model. The photoluminescence (PL) intensity decreased with increasing degree of I$_2$-doping, and the Infrared (IR) spectrum analysis revealed that the dopants are not directly coupled to the polymer, but effect motions of the methyl and phenyl groups.

  • PDF

An Investigation on Migration of Uranium in Soils and Plants in a Phytoremediation System

  • Chang, Pei-chun;Satoshi-Yoshida;Kim, Kyoung-Woong;Kim, Soo-Young
    • Proceedings of the KSEEG Conference
    • /
    • 2003.04a
    • /
    • pp.72-75
    • /
    • 2003
  • Plant species have shown the capability to absorb U into the biomass. Norman(l952) even suggested that uranyl ion acts as an accessory microelement in growth of Lemna and flax roots. The plants, termed metal hyperaccumulators, can extract and accumulate more than 1000-10,000mg heavy metal per kilogram of dry weight of plants (0.1-1%). The most vital main factors influencing the ability and efficiency of phytoremediation is the ability of the plant to uptake the metals from soil before the accumulation mechanism happens in the plant tissue. (omitted)

  • PDF

Evaluation of Characteristics of Water Retaining Material for Water Retaining Pavement using High Absorptiveness Resin and Foamed Concrete (고흡수성 수지와 기포콘크리트를 이용한 보수성포장용 보수재 성능 평가)

  • Lee, Soo-Hyung;Yoo, In-Kyoon
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.321-324
    • /
    • 2008
  • Water retaining pavement is a pavement to lower the surface temperature by using evaporation of the water that the pavement contains when the pavement is heated by the sun in the daytime, so, to improve performance, the performance can absorb water. Most of the high-performance material that absorbs water swell $2\sim3$ times as much volume when it contact with water. Water retaining material exists independently of the material in the cement. so it doesn't have the space to expand. Therefore, the performance of absorbing water is decreased. Therefore, this study was to develop a foamed concrete and evaluation of performance characteristics using high absorptiveness resin. The result has been evaluated as excellent compared to other materials.

  • PDF

SIMULATION OF AUTOMOTIVE SEAT FOR REDUCING NECK INJURY IN LOW-SPEED REAR IMPACT

  • CRO H. C.
    • International Journal of Automotive Technology
    • /
    • v.6 no.2
    • /
    • pp.161-169
    • /
    • 2005
  • Neck injuries sustained during low speed rear impact are the most commonly sustained traffic injury. Therefore, the analysis of neck injury mechanisms and methods for mitigating and reducing neck injuries during low speed rear impact are a very important issue in the vehicle safety field. In order to find a method to absorb the shock that is transmitted to the occupant, the response of frontal and rear dummy due to the motion of the struck vehicle and the rotational angular displacements of dummies' necks during rear impact at 12km/h speed were investigated using a Working Model 2D. The results suggest that the shock absorption system should be equipped in the bottom of the seat of the vehicle to reduce shock and mitigate neck injury to the occupants.

500VA Hybrid filter development for harmonic elimination of a single phase power (단상 전원의 고조파 제거용 500VA급 Hybrid 필터 개발)

  • Park, Jong-Yeon;Lee, Hu-Chan;Lee, Bong-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.249-253
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to absorb harmonic currents of nonlinear loads and can also improve the power factor. They are not often optimal filters because the passive filters are designed with the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. By the experimental results using the proposed system for the 500VA rectifier load, we concluded that the researched hybrid filter is cost effective and the performance is better than the passive filter.

  • PDF

Reduction of Output Voltage Ripples in Single-Phase PWM Rectifier with Active Power Decoupling Circuit

  • Nguyen, Hoang-Vu;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.419-420
    • /
    • 2015
  • In this paper, a low-cost single-phase PWM rectifier with small DC-link capacitors is proposed, where a buck-boost converter with a low power rating is added at the DC link. By controlling the auxiliary circuit so as to absorb the voltage ripple in the DC link, the second-order voltage ripple in DC-link capacitor can be reduced significantly. Therefore, a small film capacitor can be utilized to replace the bulky electrolytic capacitors. The simulation results are shown to verify the validity of the proposed method.

  • PDF

Analysis of degradation of distribution lightning arresters as degradation degree (열화정도에 따른 배전용 피뢰기의 열화특성 분석)

  • 장동욱;박동배;박영국;이용희;강성화;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.140-143
    • /
    • 2000
  • The primary function of ZnO lightning arrester is to protect transmission and distribution equipment from overvoltages and to absorb electrical energy resulting from lightning or switching surges and form temporary overvoltage. However, ZnO lightning arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage and ambient temperature. So, it is important to the leakage current measurement of ZnO lightning arrester. In addition, since the resistive leakage current caused by deterioration of ZnO lightning arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. The leakage current and third harmonic component are measured and used to investigate the degradation diagnosis of ZnO element of arrester. Also the SEM photography is used to investigate the change of crystal structure of ZnO element with degradation.

  • PDF

Simulation study of a grid-connected inverter for absorption of regenerative energy in a DC traction substation (도시철도 직류변전소의 회생전력흡수를 위한 계통연계형 인버터 시뮬레이션)

  • Bae, C.H.;Han, M.S.;Jung, H.S.;Kim, Y.K.;Park, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.279-281
    • /
    • 2005
  • In DC traction substation with 12-pulse diode rectifiers, the DC line voltage tends to rise above noload voltage because it can't absorb the regenerative power caused by electric brakes of train. To solve this problem, an IGBT regenerative inverter should be installed and thus recycles the surplus regenerative power by delivering it to the supply grid. In this paper, the DC traction substation equipped with a IGBT regenerative inverter is studied using computer simulation. Matlab/simulink is used to simulate the operation of regenerative inverter which injects the regenerative power into the supply grid and stabilizes the DC line voltage. It is confirmed that the high quality regenerative power is delivered to the supply grid thorough computer simulation.

  • PDF