• Title/Summary/Keyword: ABHS

Search Result 2, Processing Time 0.02 seconds

A Study on the Safety of Alcohol-based Hand Sanitizers (알코올을 주성분으로 하는 손소독제의 안전성 연구)

  • Sun-Ok Jung;Chun-Yeong Lee;Hoe-Jin Ryu;Hee-Jin Choi;Ji-Young Kim;Chae-Man Choi;In-Sook Hwang;Yong-Seung Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.34-39
    • /
    • 2023
  • Objectives: In this study, the safety of alcohol-based hand sanitizers (ABHSs) for quasi-drugs and cosmetics was investigated by analyzing the ethanol content, which is an active ingredient with a sterilizing effect, and methanol, which is toxic. Methods: Forty-one ABHSs were purchased at large supermarkets and online stores. Ethanol quantification was performed by gas chromatography-flame ionization detector, and methanol quantification was performed by headspace-gas chromatography-mass spectrometry. Results: The ethanol content of ABHS in quasi-drugs was 49.6-67.8%, which was suitable for standard manufacturing procedures for external disinfectants, and the ethanol content of ABHS in cosmetics was 9.1-61.3%. The methanol content of ABHS in quasi-drugs ranged from not detected(N.D.)-131.8 ppm, which was suitable for the methanol detection standard of ethanol raw materials in the Korean Pharmacopoeia. The methanol content of ABHS in cosmetics was 23.4-859.7 ppm, which was suitable for the detection limit of methanol in cosmetics. Conclusions: The ethanol and methanol content of ABHS was judged to be safe. When selecting an ABHS to be used for sterilization, it seems necessary to check the content of ethanol, an active ingredient, and use it according to its intended purpose.

The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible (하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향)

  • Jhin, Min-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.379-388
    • /
    • 2002
  • For the success of dental implant, accurate radiographic evaluation is prerequisite for planning the location of the osseointegrated implants and avoiding injury to vital structures. CT/MPR(computed tomography/multiplanar reformation) shows improved visualization of inferior alveolar canal. In order to obtain cross-sectional images parallel to the teeth, the occlusal plane is used to orientate for the axial plane. If the direction of axial plane is not parallel to the occlusal plane, the reformatted cross-sectional scans will be oblique to the planned fixture direction and will not show the actual dimension of the planned fixture's location. If the available bone height which measured in the cross-sectional view is much greater than the actual available bone height, penetration of canal may occur. The aim of this study is to assess the effect of the axial plane to measurement of available bone height for dental implant in computed tomography of the mandible. 40 patients who had made radiographic stents and had taken CT were selected. The sites that were included in the study were 45 molar regions. In the central panoramic scan, the length from alveolar crest to superior border of inferior alveolar canal(available bone height, ABH) was measured in direction of reformatted cross-sectional plane(uncorrected ABH). Then, length from alveolar crest to superior border of canal was measured in direction of stent(corrected ABH). The angle between uncorrected ABH and corrected ABH was measured. From each ABH, available fixture length was decided by $Br{{\aa}}nemark$ system. The results were following ; the difference between two ABHs was statistically significant in both first and second molar(p< 0.01). The percentage of difference more than 1 mm was 8.7% in first molar and 15.5% in second molar. The percentage of difference more than 2 mm was 2.0% in first molar and 6.6% in second molar. The maximum value of difference was 2.5 mm in first molar and 2.2 mm in second molar. The correlations between difference of 2 ABHs and angle was positive correlations in both first and second molar. The correlation coefficient was 0.534 in first molar and 0.728 in second molar. The second molar has a stronger positive correlation. The percentage of disagreement between 2 fixture lengths from two ABHs was 24.4% in first molar and 28.9% in second molar.