• 제목/요약/키워드: A6061

검색결과 387건 처리시간 0.027초

단섬유보강 금속복합재료의 반복적 변형 및 피로특성 (Cyclic Deformation and Fatigue Behavior of Short Fiber Reinforced Metal Matrix Composites)

  • 양유창;송정일;한경섭
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1422-1430
    • /
    • 1995
  • Al6061 alloy reinforced with 15 volume% of Saffil fibers was fabricated by squeeze infiltration method. Uniform distribution of reinforcements and good bondings between reinforcements and matrix alloy were found in the microstructure of composites. Comparing with A16061 matrix alloy, tensile strength and elastic modulus of $Al_{2}$O$_{3}$/Al composites were increased up to 26% and 31%, respectively. Cyclic deformation and fatigue behavior of $Al_{2}$O$_{3}$/Al metal matrix composites were studied. The specimens were cycled using tension-tension(R=0.1) loading and under load controlled fatigue test. Cyclic stress-displacement curve through fatigue test was obtained. Fatigue strength of $Al_{2}$O$_{3}$/Al composites was about 200 MPa, i.e.0.55 of applied stress level(q). During fatigue test, $Al_{2}$O$_{3}$/Al composites displayed cyclic hardening at all applied stress levels. The most of resultant displacement due to permanent plastic deformation occurred in less than the first 5% of fatigue life. Displacement-to-failure of the fatigue test was smaller than that of the tensile test because of accumulative damage by cumulative plastic deformation.

공구와 공작물의 상대적 변형량 예측을 위한 해석모델 개발에 관한 연구 (A Study on the Development of Analysis Model for Prediction of Relative Deformation between Cutting Tool and Workpiece)

  • 이문재;황영국;이춘만
    • 한국정밀공학회지
    • /
    • 제27권4호
    • /
    • pp.20-26
    • /
    • 2010
  • Any relative deformation between the cutting tool and the workpiece at the machining point, results directly in form and dimensional errors. The source of relative deformations between the cutting tool and the workpiece at the contact point may be due to thermal, weight, and cutting forces. This paper presents an investigation into dry and fluid machining with the objective of evaluating shape accuracy effect for the turning process of Al6061. The thermal distribution of cutting tool and cutting force was predicted using finite element method after measuring the temperature of the tool holder. To reach this goal, shape accuracy turning experiments are carried out according to cutting conditions with dry and fluid machining methods. The variable cutting conditions are cutting speed, depth of cutting and feed rate.

급속응고 및 Stone Mill 공정에 의해 제조된 하이브리드 Al2O3-TiC/Al 복합재료의 미세조직 (Microstructure of the Hybrid Al2O3-TiC/Al Composite by Rapid Solidification and Stone Mill Process.)

  • 김택수;이병택;조성석;천병선
    • 한국분말재료학회지
    • /
    • 제10권1호
    • /
    • pp.15-20
    • /
    • 2003
  • Hybrid $A1_2O_3-TiC$ ceramic particle reinforced 6061 and 5083 Al composite powders were prepared by the combination of twin rolling and stone mill crushing process, followed by consolidating processes of cold compaction, degassing and hot extrusion. The composite bar consists of lamellar structure of ceramic particle rich area and matrix area, in which the hybrid was decomposed into each TiC of about $3-4\mutextrm{m}$ and $AI_2O_3$ particles of about $1-2\mutextrm{m}$ in diameter. It also found that fine $Mg_2Si$ precipitates of about 30 nm were embedded in the matrix, which have grains of about 3 $\mutextrm{m}$. Higher UTS was measured at the 5083 composite bar compared to the conventionally fabricated composite, due to again refinement effect by the rapid solidification. No particle was shown to form in the interface between the matrix and reinforcement, whereas carbon was diffused into the matrix.

온간 하이드로포밍 공정을 위한 시스템 설계 (Process Design for the Tubular Hydroforming at Elevated Temperatures)

  • 김봉준;박광수;손성만;이문용;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.226-229
    • /
    • 2006
  • Process design has been performed for the warm hydroforming of light weight alloy tubes. For the heating of tubes, specially designed induction heating system has been adopted to ensure rapid heating of tubes. The induction heating system uses 30kHz frequency induction coil in order to concentrate the energy in the tube and prevent the energy loss. But the induced heat by the integrated heating system, consisting of induction coil, tube, pressure oil and dies, was normally not equally distributed over the length and circumference of the tube specimen, and consequent temperature distribution was non-uniform. So additional heating element has been inserted into the inside of the tube to maintain the forming temperature and reduce temperature drop due to heat loss to the molds. And for that heat loss, a heat insulation system has also been installed. The drop in flow stress at elevated temperatures results in lower internal pressure for hydroforming and lower clamping forces. The proposed warm hydroforming process has been successfully implemented when applying 6061 aluminum extruded tubes.

  • PDF

초음파 신호분석을 이용한 접착접합 이음의 파괴역학적 평가 (A Fracture Mechanics Approach to Adhesively Bonded Joint Using Ultrasonic Signal Analysis)

  • 한준영;오승규;윤송남;이원;장철섭;김민건;김환태
    • Journal of Welding and Joining
    • /
    • 제21권5호
    • /
    • pp.555-560
    • /
    • 2003
  • In automobile industry, it is necessary to reduce the weight from the view point of energy and environmental problems in these days. One of the ways for weight reduction is using adhesive aluminum structures. In this study, ultrasonic signals reflected from the adhesively bonded joint layer are used to evaluate the adhesively bonded joints. FFT is performed to determine bond-layer parameters such as effective thickness and frequency for adhesively bonded joint Al 6061 plates in comparison with the measured and theoretical ratios. And the parameters of ultrasonic wave and the J-integral are investigated to evaluate the adhesively bonded joint strength by DCB specimens.

미세정밀밀링 가공을 위한 검사시편의 가공조건에 따른 표면거칠기에 대한 영향 분석 (The Effect of Surface Roughness according to Machining Conditions of Test Specimen for Precision Micro-milling Machining)

  • 심민섭;김동현;이춘만
    • 한국정밀공학회지
    • /
    • 제32권1호
    • /
    • pp.49-55
    • /
    • 2015
  • Recently, many researchers and industry are looking for ways to decrease the use of lubricants because of economical and environmental reasons. One of the lubrication technologies is the MQL method. This study presents a research of MQL and Wet milling processes of Al 6061 material. For this experiment, the test specimen is suggested, and various machining conditions are applied. And, shape of micro-pattern which has been recently spotlighted is included in the test specimen. In order to compare MQL with Wet machining, several milling experiments were carried out, varying feed rate, cutting speed, depth of cut, etc. Finally, the surface roughness results of machining tests according to the process conditions were measured. It is expected that the results of machining experiments can be used to predict the surface roughness of various MQL milling processes.

TiNi/Al 형상기억 지적복합재료의 기계적 특성 및 강화기구 (Material Properties and Strengthening Mechanism in Shape Memory TiNi Fiber Reinforced Al Matrix composite)

  • 박영철;윤두표;이규창
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.405-413
    • /
    • 1997
  • In the present paper, it is attempted to reconfirm the "Intelligent" material properties using both the sintered TiNi/Al(1100) matrix composite made by powder metallurgy method and the squeeze-casted TiNi/Al6061 specimens. A metal matrix composite is, its fault has been considered to deteriorate a strength of composite by heating residual stress of the matrix. Therefore, it is necessary to remove a tensile residual stress, to produce the strength of a composite better. On the contrary, if compressive residual stress happens in matrix of composite in place of tensile residual stress, it will make the strength of composite better. So that, this paper introduce the development of a high strength of composite, by using compressive residual stress well, on the study. By using these specimens, shape memory strengthening effects in tensile strength and fatigue crack propagation above inverse transformation temperature of TiNi fiber were investigated. We occurs the prestrain and volume fraction for to discuss the effects of a composite strength. Moreover, by SEM observation, the effect of the residual stress at the interface between Al matrix and TiNi fiber and some brittle precipitation layers such as inter metallic compounds on fracture mechanisms was discussed metallurgically.urgically.

Immersion grating mount design of IGRINS

  • 문봉곤;;박찬;이성호;육인수;천문영
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.153.2-153.2
    • /
    • 2011
  • The IGRINS (Immersion GRating INfrared Spectrometer) is a high resolution wide-band infrared spectrograph developed by Korea Astronomy and Space Science Institute (KASI) and the University of Texas at Austin (UT). Immersion grating is a key component of IGRINS, which disperses the input ray by using a Silicon material with a lithography technology. Opto-mechanical mount for the immersion grating is important to keep the high spectral resolution and the optical alignment in a cold temperature of $130{\pm}0.06K$. The optical performance of immersion grating can maintain within the de-center tolerance of ${\pm}0.05mm$ and the tip-tilt tolerance of ${\pm}1.5arcmin$. The mount mechanism utilizes the flexure and the kinematic support design to satisfy the requirement and the operation condition. When the IGRINS system is cooled down to a cold temperature, three flexures compensate the thermal contraction stress due to the different material between the immersion grating and the mounting part(Aluminum 6061). They also support the immersion grating by an appropriate preload. Thermal stability is controlled by a copper strap with proper dimensions and a heater. Generally structural and thermal analysis was performed to confirm the mount mechanism. This talk presents the opto-mechanical mount design of the immersion grating of IGRINS.

  • PDF

Performance Analysis for Mirrors of 30 cm Cryogenic Space Infrared Telescope

  • Park, Kwi-Jong;Moon, Bong-Kon;Lee, Dae-Hee;Jeong, Woong-Seob;Nam, Uk-Won;Park, Young-Sik;Pyo, Jeong-Hyun;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.321-328
    • /
    • 2012
  • We have designed a 30 cm cryogenic space infrared telescope for astronomical observation. The telescope is designed to observe in the wavelength range of 0.5~2.1 ${\mu}m$, when it is cooled down to 77 K. The result of the preliminary design of the support structure and support method of the mirror of a 30 cm cryogenic space infrared telescope is shown in this paper. As a Cassegrain prescription, the optical system of a 30 cm cryogenic space infrared telescope has a focal ratio of f/3.1 with a 300 mm primary mirror (M-1) and 113 mm secondary mirror (M-2). The material of the whole structure including mirrors is aluminum alloy (Al6061-T6). Flexures that can withstand random vibration were designed, and it was validated through opto-mechanical analysis that both primary and secondary mirrors, which are assembled in the support structure, meet the requirement of root mean square wavefront error < ${\lambda}/8$ for all gravity direction. Additionally, when the M-1 and flexures are assembled by bolts, the effect of thermal stress occurring from a stainless steel bolt when cooled and bolt torque on the M-1 was analyzed.

Pulsed UV를 이용한 CSOs 소독시 반사체에 따른 처리효율 연구 (A Study of Treatment Efficiency of Reflectors for CSOs Disinfection by Pulsed UV)

  • 한종훈;허지용;김강욱;이준영;박원석;이종열;허남국
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권1호
    • /
    • pp.36-40
    • /
    • 2015
  • This study examined the disinfection in combined sewer overflows (CSOs) by pulsed ultraviolet (PUV). The reflectors (stainless steel. mirror, aluminium foil, aluminium (1050), aluminium (6061), aluminium (5052), and aluminium mirror) of PUV irradiation was performed in a 90 L stainless reactor at a constant temperature of $20^{\circ}C$ and an applied power of 4000 W. The reflection efficiency of reflectors were showed 1.00 (aluminium mirror) ~ 1.48 (aluminium foil) does. The case of a rough surface analysis using SEM showed high reflectance, was the case of a smooth surface and a low reflectivity. Pseudo first-order rate constant calculated results, has a higher reflectivity values were more than twice as high compared to the low reflectivity. Affected Total coliforms disinfection time, depending on the type of reflector is considered.