• Title/Summary/Keyword: A.O.

Search Result 52,031, Processing Time 0.085 seconds

Radiosynthesis of $[^{11}C]6-OH-BTA-1$ in Different Media and Confirmation of Reaction By-products. ($[^{11}C]6-OH-BTA-1$ 조제 시 생성되는 부산물 규명과 반응용매에 따른 표지 효율 비교)

  • Lee, Hak-Jeong;Jeong, Jae-Min;Lee, Yun-Sang;Kim, Hyung-Woo;Lee, Eun-Kyoung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.241-246
    • /
    • 2007
  • Purpose: $[^{11}C]6-OH-BTA-1$ ([N-methyl-$^{11}C$]2-(4'-methylaminophenyl)-6-hydroxybenzothiazole, 1), a -amyloid imaging agent for the diagnosis of Alzheimer's disease in PET, can be labeled with higher yield by a simple loop method. During the synthesis of $[^{11}C]1$, we found the formation of by-products in various solvents, e.g., methylethylketone (MEK), cyclohexanone (CHO), diethylketone (DEK), and dimethylformamide (DMF). Materials and Methods: In Automated radiosynthesis module, 1 mg of 4-aminophenyl-6-hydroxybenzothiazole (4) in 100 l of each solvent was reacted with $[^{11}C]methyl$ triflate in HPLC loop at room temperature (RT). The reaction mixture was separated by semi-preparative HPLC. Aliquots eluted at 14.4, 16.3 and 17.6 min were collected and analyzed by analytical HPLC and LC/MS spectrometer. Results: The labeling efficiencies of $[^{11}C]1$ were $86.0{\pm}5.5%$, $59.7{\pm}2.4%$, $29.9{\pm}1.8%$, and $7.6{\pm}0.5%$ in MEK, CHO, DEK and DMF, respectively. The LC/MS spectra of three products eluted at 14.4, 16.3 and 17.6 mins showed m/z peaks at 257.3 (M+1), 257.3 (M+1) and 271.3 (M+1), respectively, indicating their structures as 1, 2-(4'-aminophenyl)-6-methoxybenzothiazole (2) and by-product (3), respectively. Ratios of labeling efficiencies for the three products $([^{11}C]1:[^{11}C]2:[^{11}C]3)$ were $86.0{\pm}5.5%:5.0{\pm}3.4%:1.5{\pm}1.3%$ in MEK, $59.7{\pm}2.4%:4.7{\pm}3.2%:1.3{\pm}0.5%$ in CHO, $9.9{\pm}1.8%:2.0{\pm}0.7%:0.3{\pm}0.1%$ in DEK and $7.6{\pm}0.5%:0.0%:0.0%$ in DMF, respectively. Conclusion: The labeling efficiency of $[^{11}C]1$ was the highest when MEK was used as a reaction solvent. As results of mass spectrometry, 1 and 2 were conformed. 3 was presumed.

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF

Distribution of Indicator Organisms and Influence of Storage Temperature and Period in Commercial Animal Foods (시판 동물성 식품의 오염지표세균 분포 및 저장온도, 기간별 오염지표세균의 변화)

  • 이용욱;박석기
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.4
    • /
    • pp.430-440
    • /
    • 1998
  • The average number of total viable counts for the commercial pork tested was 19/g, coliform 1.8/g, psychrophilic bacteria 15/g, heterotrophic bacteria 12/g, fecal streptococcus 6.2/100 g, Pseudomonas aeruginosa 13/100 g and none of heat-resistant bacteria and Staphylococcus was detected. That for the commercial beef tested was 130/g, coliform 5.2/g, psychrophile 140/g, heterotroph 28/g, Staphylococcus 1.2/g, fecal streptococcus 9.5/100 g, Pseud. aeruginosa 1.9/100 g and heat-resistant bacteria was not detected. That for the commercial chicken tested was 8800/g, coliform 53/g, psychrophile 4600/g, heterotroph 4700/g, fecal streptococcus 9.9/100 g, Pseudo aeruginosa 2.5/100 g. That for milk was 4700/ml, psychrophile 120/ml, heterotroph 420/ml and the others were not detected. That for the commercial cheese was 3.2/g, psychrophile 2.3/g, heterotroph 1.6/g, Staphylococcus l/g, fecal streptococcus 9.1/g. That for fermented milk was $10^{7}/ml$, heatresistant bacteria $10^{6}/ml$, fecal streptococcus 2400/100 ml, lactobacillus $3.2{\times}10^{15}/ml$, in accordance with lactic acid bacteria and the others were not detected. There was not detected any indicator organisms from ham, sausage, butter, eggs and quails in the commercial fooods tested. SPC, coliform, psychrophile and heterotroph in commercial meats stored at $10^{\circ}C$ were increased rapidly as time goes on but heat-resistant bacteria, staphylococcus, fecal streptococcus and Pseudo aeruginosa were constant. At $20^{\circ}C$, SPC, coliform, psychrophile, heterotroph and fecal streptococcus were the highest at 7 days and heat-resistant bacteria, staphylococcus and Pseudo aeruginosa were increased a little. At $30^{\circ}C$, all indicators were increased rapidly for 3 and 7 days and then decreased rapidly. All indicator organisms were increased at the level of 10/g for 14 days in meat products stored at $10^{\circ}C$, but SPC, psychrophile and heterotroph in meat products stored at $20^{\circ}C$ were increased at the level of $lO^5/g$. It showed that the indicators in meat products stored at $30^{\circ}C$ had a tendency to increase at the level of $10^{2}/g$ relative to those stored at $20^{\circ}C$. SPC, psychrophile and heterotroph in milk stored at $10^{\circ}C$ increased up to the level of $10^4/ml$, but coliform, staphylococcus, fecal streptococcus and Pseudo aeruginosa were not detected. As stored at $20^{\circ}C$ and $30^{\circ}C$, they were increased rapidly for 1 or 3 days and then constant for a long time.

  • PDF

A study of $Smartpeg^{TM}'s$ lifetime according to sterilization for implant stability (임플랜트 안정성을 위한 자기공명막대의 소독방법에 따른 수명에 관한 연구)

  • Won, Ho-Yeon;Cho, In-Ho;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.42-52
    • /
    • 2008
  • Purpose: Resonance Frequency Analysis(RFA) technique can be used as an effective method in measuring the implant stability and documenting the clinical results. This technique also determines how stable the implant is before performing a prosthetic practice. Having become one the guidelines of the implant therapy whose final objective is the immediate loading, the $Osstell^{TM}$ mentor is giving a lot of information to the clinicians recently. In this communication, experiments were performed to investigate how reliable the measured ISQ values by $Osstell^{TM}$ mentor are, and to see if those are also stable even after sterilization. As five objectives: 1) How stable measured ISQ values after fixation $Smartpeg^{TM}s$ for 400 times. 2) How stable measured ISQ values after 'attach-detach'$Smartpeg^{TM}'s$ for 400 times. 3) How stable measured ISQ values after clinical sterilization methods. 4) How stable measured ISQ values after repeatedly sterilization in autoclave for 10 times. 5) What is the critical temperature which is lost the magnetism of $Smartpeg^{TM}$. Materials and Methods: Clinical sterilization methods(Autoclave sterilization, Dentistar sterilization, Ultra violet sterilization, Vacuum dry unit sterilization, Boiling water sterilization, combined $H_{2}O_{2}$ and Alcohol sterilization).$Smartpeg^{TM}s$. D3 Block bone($3{\times}9{\times}2cm$). Osstem implant(${\emptyset}4.1$-10mm).$Osstell^{TM}$ mentor. Individual experiment was used 8 number of $Smartpeg^{TM}s$ and they had measured to ISQ values of before experiment and after experiment. Results: 1. The measured ISQ values did not change after fixation $Smartpeg^{TM}s$ for 400 times. 2. There was no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ for 400 times. 3. The measured ISQ values did not change after the usual clinical sterilization methods. 4. The measured ISQ values did not change after sterilization in autoclave for 10 times. 5. It was impossible to exactly measure the critical temperature which is lost the magnetism of $Smartpeg^{TM}s$. But, the results was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10 minute. Conclusion: The measured ISQ values showed insignificant differences in case of no changes in the magnetism of the $Smartpeg^{TM}s$. It seems that the $Smartpeg^{TM}s$ can be used repeatedly in every measurement if the original magnetisms of the $Smartpeg^{TM}s$ can be recognized. There seems to be no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ only if the screw pitches were unimpaired. The clinical sterilization methods seems acceptable because the result was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10minute.

Characteristics of Spatio-temporal Variation of the Water Quality in the Lower Keum River (금강 하류역에서 수질의 시공간적 변화특성)

  • YANG Han-Soeb;KIM Seong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.23 no.3
    • /
    • pp.225-237
    • /
    • 1990
  • Various chemical constituents were measured from April to August 1988 at the down-ward 20 stations of Keum River, which is located in the Midwest of Korea, to understand the characteristics of water quality with respect to spatio-temporal variations of each constituent. The 24-hrs continuous measurements with 2-hrs interval were made simultaneously at station 2 near the estuary weir and station 9(Ganggyeong) of 35 km upstream from the weir in April. By the results observed for one day in April at station 2, salinity has a range of $7.88\~22.14\%_{\circ}$ and its temporal variability is identical to the pattern of tidal cycle in the neigh-bouring Kunsan Harbor. However, turbidity shows relatively high values only at an interval of 4~5 hours after the lowest salinity time, though hourly fluctuation of pH is very small. Silicate and dissolved inorganic nitrogen have inversively linear correlationships with salinity, implying the concentration of the two nutrients strongly regulated by estuarine mixing of sea and river waters. In contrast, phosphate sustains roughly a constant level over a wide salinity range and distinctly lower values than those corresponding to nitrate in the oceans. Such distributions of phosphate have been observed in some estuaries, and interpreted as driven by removal of dissolved phosphate into bottom sediments and the bufforing of phosphate by particulate matter. COD values at station 2 are relatively high in day-time(particularly afternoon) and in high-salinity periods. At station 9, saltwater intrusion was never found but water level changed to the extent of 2.5 m for one day. Although each parameter at this station exhibits very slight variations in their abundance for 24 hours compared with station 2, the contents of COD, silicate and ammonia are significantly higher than at station 2. Concentration of suspended matter is relatively high in the brackish water region up to $\~20$ km above the river mouth, probably due to strong tidal stirring of the bottom de-posits. Also, relatively high pH, COD and $O_2$ saturation at the upward stations of $40\~50$ km from the weir are presumably attributable to active photosynthesis of plants in the region. In general, COD and nutrients except phosphate are higher values at the upper stations than in the estuary zone, and show the highest abundances in July nearly at all stations. Finally, in the estuarine region tidal mixing of sea-river waters seems to be an important factor controlling the distributions of turbidity, COD, silicate and nitrate as well as salinity. However, water quality in the upward fresh-water zone is remarkably variable according to months or seasons.

  • PDF

Clinical Characteristics of Recurred Patients with Stage I,II Non-Small Cell Lung Cancer (근치적 절제 후 재발한 1,2기 비소세포폐암 환자의 임상상)

  • Ham, Hyoung-Suk;Kang, Soo-Jung;An, Chang-Hyeok;Ahn, Jong-Woon;Kim, Ho-Cheol;Lim, Si-Young;Suh, Gee-Young;Kim, Kwhan-Mien;Chung, Man-Pyo;Kim, Ho-Joong;Kim, Jhin-Gook;Kwon, O-Jung;Shim, Yong-Mog;Rhee, Choong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.428-437
    • /
    • 2000
  • Background : Five year survival rate of postoperative stage I non-small cell lung cancer(NSCLC) reaches to 66%. In the remaining one third of patients, however, cancer recurs and the overall survival of NSCLC remains dismal. To evaluate clinical and pathologic characteristics of recurred NSCLC, the patterns and factors for postoperative recurrence in patients with staged I and II NSCLC were studied. Method : A retrospective analysis was performed in 234 patients who underwent radical resection for pathologic stage I and II NSCLC. All patients who were followed up for at least one year were included in this study. Results : 1) There were 177 men and 57 women The median age was 63. The median duration of the follow up period was 732 days (range 365~1,695 days). The overall recurrence rate was 26.5%, and the recurrence occurred $358.8{\pm}239.8$ days after operation. 2) The ages of recurred NSCLC patients were higher ($63.2{\pm}8.8$ years) than those of non-recurred patients ($60.3{\pm}9.8$ years)(p=0.043). The recurrence rate was higher in stage II (46.9%) than in stage I (18.8%) NSCLC p<0.001. The size of primary lung mass was larger in recurred ($5.45{\pm}3.22\;cm$) than that of non-recurred NSCLC ($3.74{\pm}1.75\;cm$, p<0.001). Interestingly, there were no recurrent cases when the resected primary tumor was less than 2cm. 3) Distant recurrence was more frequent than locoregional recurrence (66.1% vs. 33.9%). Distant recurrence rate was higher in females and in cases of adenocarcinoma. Brain metastasis was more frequent in patients with adenocarcinoma than in those with squamous cell carcinoma (p=0.024). Conclusion: The tumor size and stage were two important factors for determining the possibility of a recurrence. Because distant brain metastasis was more frequent in patients with adenocarinoma, a prospective study should be conducted to evaluate the effectiveness of preoperative brain imaging.

  • PDF

Clinical Differential Diagnosis of Usual Interstitial Pneumonia from Nonspecific Interstitial Pneumonia (통상성 간질성 폐렴과 비특이성 간질성 폐렴의 임상적 감별 진단)

  • An, Chang-Hyeok;Koh, Young-Min;Chung, Man-Pyo;Suh, Gee-Young;Kang, Soo-Jung;Kang, Kyeong-Woo;Ahn, Jong-Woon;Lim, Si-Young;Kim, Ho-Joong;Han, Jeung-Ho;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.932-943
    • /
    • 2000
  • Background : Nonspecific interstitial pneumonitis (NSIP) is most likely to be confused with usual interstitial pneumonitis (UIP). Unlike patients witþ UIP, the majority of patients with NSIP have a good prognosis, with most patients improving after treatment with corticosteroids. Therefore it is clinically important to differentiate NSIP from UIP. Up to now, the only means of differentiating these two diseases was by means of surgical lung biopsy. American Thoracic Society (ATS) proposed a clinical diagnostic criteria for UIP to provide assistance to clinicians in its diagnosis without surgical lung biopsy. This study is aimed to investigate whether there were clinical and radiological differences between NSIP and UIP, and the usefulness of ATS clinical diagnostic criteria for UIP in Korea. Methods : We studied 60 patients with UIP and NSIP confirmed by surgical lung biopsy. Clinical manifestations, pulmonary function test, arterial blood gas analysis, bronchoalveolar lavage (BAL), and high resolution computed tomography (HRCT) were evaluated and analyzed by Chi-square test or t-test. The clinical criteria for UIP proposed by ATS were applied to all patients with idiopathic interstitial pneumonia. Results : Forty-two patients with UIP and 18 with NSIP were pathologically identified. Among the 18 patients with NSIP (M : F=1 : 17), the mean age was 55.2$\pm$8.4 (44~73) yr. Among the 42 patients with UIP (M : F=33 : 9), the mean age was 59.5$\pm$7.1 (45~74) yr (p=0.046). Fever was more frequent in NSIP (39%) (p=0.034), but clubbing was frequently observed in UIP (33%) (p=0.023). BAL lymphocytosis was more frequent (23%) (p=0.0001) and CD4/CD8 ratio was lower in NSIP (p=0.045). On HRCT, UIP frequently showed honeycomb appearance (36 of 42 patients) though not in NSIP (p=0.0001). Six of 42 UIP patients (14.3%) met the ATS clinical criteria for IPF, and 3 of 16 NSIP patients (18.8%) met the diagnostic criteria. Conclusion : Being a relatively young female and having short duration of illness, fever, BAL lymphocytosis, low CD4/CD8 ratio with the absence of clubbing and honeycomb appearance in HRCT increase the likelihood of the illness being NSIP. The usefulness of ATS clinical diagnostic criteria for UIP may be low in Korea.

  • PDF

A Study of Endothelium-dependent Pulmonary Arterial Relaxation and the Role of Nitric oxide on Acute Hypoxic Pulmonary Vasoconstriction in Rats (흰쥐 폐동맥의 내피세포의존성 혈관이완과 급성 저산소성 폐동맥수축에서 산화질소의 역할)

  • In, Kwang-Ho;Lee, Jin-Goo;Cho, Jae-Youn;Shim, Jae-Jung;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.231-238
    • /
    • 1994
  • Backgroud: Since the demonstration of the fact that vascular relaxation by acetylcholine(Ach) results from the release of relaxing factor from the endothelium, the identity and physiology of this endothelium-derived relaxing factor(EDRF) has been the target for many researches. EDRF has been identified as nitric oxide(NO). With the recent evidences that EDRF is an important mediator of vascular tone, there have been increasing interests in defining the role of the EDRF as a potential mediator of hypoxic pulmonary vasoconstriction. But the role of EDRF in modulating the pulmonary circulation is not compeletely clarified. To investigate the endothelium-dependent pulmonary vasodilation and the role of EDRF during hypoxic pulmonary vasoconstriction, we studied the effects of $N^G$-monomethyl-L-arginine(L-NMMA) and L-arginine on the precontracted pulmonary arterial rings of the rat in normoxia and hypoxia. Mothods: The pulmonary arteries of male Sprague Dawley(300~350g) were dissected free of surrounding tissue, and cut into rings. Rings were mounted over fine rigid wires, in organ chambers filled with 20ml of Krebs solution bubbled with 95 percent oxygen and 5 percent carbon dioxide and maintained at $37^{\circ}C$. Changes in isometric tension were recorded with a force transducer(FT.03 Grass, Quincy, USA) Results: 1) Precontraction of rat pulmonry artery with intact endothelium by phenylephrine(PE, $10^{-6}M$) was relaxed completely by acetylcholine(Ach, $10^{-9}-10^{-5}M$) and sodium nitroprusside(SN, $10^{-9}-10^{-5}M$), but relaxing response by Ach in rat pulmonary artery with denuded endothelium was significantly decreased. 2) L-NMMA($10^{-4}M$) pretreatment inhibited Ach($10^{-9}-10^{-5}M$)-induced relaxation, but L-NMMA ($10^{-4}M$) had no effect on relaxation induced by SN($10^{-9}-10^{-5}M$). 3) Pretreatment of the L-arginine($10^{-4}M$) significantly reversed the inhibition of the Ach ($10^{-9}-10^{-5}M$)-induced relaxation caused by L-NMMA($10^{-4}M$) 4) Pulmonary arterial contraction by PE($10^{-6}M$) was stronger in hypoxia than normoxia but relaxing response by Ach($10^{-9}-10^{-5}M$) was decreased, 5) With pretreatment of L-arginine($10^{-4}M$), pulmonary arterial relaxation by Ach($10^{-9}-10^{-5}M$) in hypoxia was reversed to the level of relaxation in normoxia. Conclusion: It is concluded that rat pulmonary arterial relaxation by Ach is dependent on the intact endothelium and is largely mediated by NO. Acute hypoxic pulmonary vasoconstriction is related to the suppression on NO formation in the vascular endothelium.

  • PDF

The Influences of Maintenance Hemodialysis on Sleep Architecture and Sleep Apnea in the Patients with Chronic Renal Failure (만성신부전 환자에서 혈액투석 유지요법이 수면구조 및 수면 무호흡에 미치는 영향)

  • Park, Yong-Geun;Lee, Sang-Haak;Choi, Young-Mee;Ahn, Seok-Joo;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.824-835
    • /
    • 1999
  • Background: Sleep-related breathing disorders are commonly found in patients with chronic renal failure and particularly, sleep apnea may have an influence on the long-term mortality rates in these patients. Maintenance hemodialysis is the mainstay of medical measures for correcting the metabolic derangements of chronic renal failure but it is uncertain whether it may alleviate sleep disorders including sleep apnea. Methods: Forty seven patients on maintenance hemodialysis were surveyed with the sleep questionnaire about their clinical symptoms related to sleep disorders. Among them, 15 patients underwent the polysomnography and their blood levels of urea nitrogen, creatinine, electrolytes and the arterial blood gases in the nights before and following hemodialysis were measured. Results: Forty(85.1%) of the 47 patients complained of the symptoms associated with sleep-wake cycle disturbances, 55.3% experienced snoring and 27.7% reported witnessed apneas. The duration of REM sleep increased significantly in the nights after hemodialysis compared to the nights without hemodialysis(p<0.05) and the percentage of total sleep time comprising NREM sleep decreased significantly in the nights following hemodialysis compared to the nights before hemodialysis(p<0.05). The percentage of total sleep time consisting of the stage 1 and 2 NREM sleep showed the trend for a decrease in the nights after hemodialysis(p=0.051), while the percentage of total sleep time comprising the stage 3 and 4 NREM sleep did not change between nights. The obstructive sleep apnea was more predominant type than the central one in both nights and there were no differences in the apnea index and the apnea-hypopnea index between the nights. The decrease in the blood level of urea nitrogen, creatinine, potassium and phosphorus was observed after hemodialysis(p<0.05), but the differences of parameters measured during polysomnography between the nights did not correlate with the changes of biochemical factors obtained on the two nights. Arterial blood gas analysis showed that pH was significantly greater in the nights after hemodialysis than in the nights before hemodialysis(p<0.05), but there were no correlations between the parameters examined during polysomnography and the parameters of arterial blood gas analysis(p<0.05). Conclusion: These results suggest that chronic renal failure is an important systemic disorder which is strongly associated with sleep disorders. Maintenance hemodialysis, although it is a widely accepted measure to treat chronic renal failure, did not significantly modulate the sleep architecture and the severity of sleep apnea. Thus, taking the patients with chronic renal failure into account, it is advisable to try not only to find a substantial way for correcting metabolic derangements but also to consider the institution of more effective treatments for sleep disorders.

  • PDF

A Study on Labor Saving in Paddy Rice Cultivation (논벼재배에 있어서의 노동력 절감에 관한 연구)

  • Young-Chul Chang
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.11
    • /
    • pp.81-97
    • /
    • 1972
  • Experiments and investigations were done basically and practically for the purpose of labor saving in paddy rice cultivation especially on Homizil i.e. hoeing and herbicide, 1969. 8 concrete tanks were established on the open base of Keon Kuk University for comparison of percolation, dissolved oxygen and yield test of rice in the paddy plot of tank. The dimension of the bottom of each tank is square meter. Each of the 4 of the 8 tanks is 21cm in height and each of the remaining 4 tanks is 36cm. Each tank has a system that comprises 2 sets of tubes, each of which has 20 holes of 5mm in diameter scattered every side and is covered with nylon cloth taking water in the tank. One set consists of 4 P.V.C tubes. The first set is situated 8cm below the top of the tank and the second set is located at bottom layer inside the tank. The 4 tubes of each set are combined together and led to the glass tube which protects from inside to outside. And this inside-outside glass tube is connected to the small rubber tube. Also a glass tube is set 4cm below the top of the tank. Paddy loam was filled on sand in each of the tanks in the soil depth of either 15cm or 30cm. The depth of sand was 5cm in the soil depth of 15cm and 10cm in the soil depth of 30cm. (Fig. 1, 2 and 3). The paddy rice was grown in the tank. The percolation of water, the dissolved oxygen and the yield of rice were observed in the tank. And the dissolved oxygen was detected by Winkler method. A sandy paddy field of heavy percolation was selected at the field of the National Agricultural Material Inspection Center in Seoul. It was divided into 9 plots. These plots were given 3 treatments: (A) not hoeing, (B) hoeing one time and (C) hoeing two times. These treatments were replicated 3 times along the latin square design. The paddy rice was grown and sprayed with Stam F-34 in the all plots for the purpose of killing weeds before hoeing. The two types of paddy of field i.e. one for normal percolation and the other for ill drainage were selected at Iri Crop Experiment Station, Jeonla-Bukdo. Each field was divided into 24 plots for 8 treatments. They are: (A) not hoeing; (B) hoeing one time; (C) hoeing two times; (D) not hoeing but treating with herbicide, Pamcon; (E) hoeing one time and weeding two times also treating with herbicide, Pamcon; (F) hoeing two times and weeding one time a], o treating with herbicide, Pamcon; (G) hoeing two times and weeding two times also treating with herbicide, Pamcon, ; (H) usual manner. The labor hours and expenses needed for weeding in the paddy by hoeing were investigated in a farmer at Suwon and the price of herbicide and the yield of rice were taken out at Iri, Jeonla-Bukdo. The results obtained from the above experiments and investigations are as follows: 1. The relationship between percolation and dissolved oxygen shows that a very small amount of oxygen is detected in the soil water under 2cm below surface of earth in the paddy even when percolation is over 4.0cm per 24 hours (Tab. 1). 2. The relationship between percolation and yield of rice shows that the yield of rice increases in the percolation of 0cm and 1.5cm per 24 hours and decreases in the percolation of 2.5cm and 3.4cm in the plot of the 15cm ploughing depth and increases in the percolation of 1.4cm and 3.0cm and decreases in the percolation of 0cm and 4.0cm in the plot of 30cm ploughing depth (Tab. 1 and Fig. 5). 3. The yield of paddy weeded with Stam F-34 in the sandy field of heavy percolation in Seoul was 3.02 tons in the plot of not hoeing, 2.99 tons in hoeing one time and 3.05 tons in hoeing two times per hectare (Tab. 5). 4.1). 4. 1) The yield of rice per 10 ares in the field of normal percolation at Iri was 338kg in not hoeing, 379kg in hoeing one time, 383kg in hoeing two times, 413kg in spraying herbicide, Pamcon, and not hoeing, 433kg in spraying herbicide, Pamcon, and hoeing one time and weeding two times, 399kg in spraying herbicide, Pamcon, and hoeing two times and weeding one time, 420kg in spraying herbicide, Pamcon, and hoeing two times and weeding two times and 418kg in usual manner (Tab. 6-1). 2) The yield of rice per 10 ares in the field of ill drainage at Iri was 323kg in not hoeing, 363kg in hoeing one time, 342kg in hoeing two times, 388kg in spraying herbicide, Pamcon, and not hoeing, 425kg in spraying herbicide, Pamcon, and hoeing one time and weeding two times, 427kg in spraying herbicide, Pamcon, and hoeing two times and weeding one time, 449kg in spraying herbicide, Pamcon, and hoeing two times and weeding two times and 412kg in usual manner (Tab. 6-2). 5. 1) The labor hours for weeding by hoeing was 37.1 hours but 53.5 hours if hours for meal, smoking and so on are included, and the expenses including labor cost needed for weeding by hoeing in the paddy rice was 2, 346 Won per 10 ares at Suwon (Tab. 7). 2) The labor hours for weeding by spraying herbicide with hand sprayer in the paddy rice was about 5 hours per 10 ares at Suwon and the expenses for weeding by spraying herbicide in the paddy rice was 750 Won but 1130 Won if the loss by decrement of rice in the paddy field of ill drainage per 10 ares is calculated in estimation at Iri (Tab. 8). From these observations and investigations it is known that using of some kinds of herbicides Saves labor and expenses of weeding, almost without giving damages to the rice itself, in the field of normal or heavy percolation comparing usual manner of hoeing.

  • PDF