• 제목/요약/키워드: A-weighted noise level

검색결과 98건 처리시간 0.023초

소비자 감성 평가를 통한 냉장고 Sound Power Spectrum Guideline (Sound Power Spectrum Guideline for a Refrigerator based on Subjective Evaluation)

  • 이진경;조경숙;이제원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.634-637
    • /
    • 2007
  • A weighted sound pressure level has been used to evaluate sounds test or sound quality test for a refrigerator up to present but the customer had different satisfactions of refrigerator sounds with different listening position. It means that there was a sound directivity caused by a position of fan or compressor. In this paper, we proposed a sound power spectrum guideline that represents total sound of refrigerator.

  • PDF

액슬 와인 음질에 대한 연구 (Sound Quality Analysis for Axle-Gear Whine Sound)

  • 김태규;이상권;조윤경;김종연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.141-146
    • /
    • 2007
  • A gear whine sound due to the axle system is one of the most important sound qualities in a sport utility vehicle (SUV). In the previous research about the gear whine sound, it was known that it is difficult to evaluate the gear whine sound objectively by using the only A-weighted sound pressure level because of the masking effect. In this paper, for the objective evaluation of the axle-gear whine sound, the characteristics of the axle-gear whine sound is at the first investigated based on the synthetic sound technology and the new objective evaluation method for the axle-gear whine sound is developed by using the sound metrics, which is the psychoacoustics parameters, and the artificial neural network (ANN) used for the modeling of the correlation between objective evaluation and subjective evaluation.

  • PDF

자동차 실내 소음의 음질 연구 (A Study on the Sound Quality of Passenger Cars)

  • 김정우;최종대;허정기;변언섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.94-101
    • /
    • 1998
  • This paper presents the psychoacoustic analyses on the vehicle interior, noise generated when accelerating. Following the objective quantification for vehicle noises of different classes, the subjective decision process by the jury test is adopted to interrelate these results based on two different approaches. In particular, the paired comparison method is employed in assessing the sound quality in terms of the quietness, the powerfulness, and the pleasantness of the human auditory sensation. Special attention is paid to the physical interpretation of psychoacoutic parameters and their interrelation to the subjective assessment scores. In order to ensure the integrity of statistics of the survey, various tests are performed. The results show that the consistency of the "quiet" sensation is far higher than that of the "powerful" and the "pleasant" sensations. Also, it is found that the most significant parameter determining these feelings turns out to be the inherent loudness of the noise instead of the conventional indicators such as the weighted sound pressure level. It may be concluded that the psychoacoustic analysis offers more realistic evaluation for vehicle noise and assists the improvement of NVH more efficiently.ement of NVH more efficiently.

  • PDF

군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향 (The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress)

  • 한상환;조수헌;고경심;권호장;하미나;주영수;신명희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권2호
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF

Identification of plastic deformations and parameters of nonlinear single-bay frames

  • Au, Francis T.K.;Yan, Z.H.
    • Smart Structures and Systems
    • /
    • 제22권3호
    • /
    • pp.315-326
    • /
    • 2018
  • This paper presents a novel time-domain method for the identification of plastic rotations and stiffness parameters of single-bay frames with nonlinear plastic hinges. Each plastic hinge is modelled as a pseudo-semi-rigid connection with nonlinear hysteretic moment-curvature characteristics at an element end. Through the comparison of the identified end rotations of members that are connected together, the plastic rotation that furnishes information of the locations and plasticity degrees of plastic hinges can be identified. The force consideration of the frame members may be used to relate the stiffness parameters to the elastic rotations and the excitation. The damped-least-squares method and damped-and-weighted-least-squares method are adopted to estimate the stiffness parameters of frames. A noise-removal strategy employing a de-noising technique based on wavelet packets with a smoothing process is used to filter out the noise for the parameter estimation. The numerical examples show that the proposed method can identify the plastic rotations and the stiffness parameters using measurements with reasonable level of noise. The unknown excitation can also be estimated with acceptable accuracy. The advantages and disadvantages of both parameter estimation methods are discussed.

공동주택 화재경보 발생음 특성에 관한 실험연구 (Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings)

  • 이민주;강희혁;권봉석;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

소비자 청감을 고려한 초 저소음 냉장고 개발 (Development of the Ultra-Silence Refrigerator with Considering Consumer's Hearing)

  • 주재만;이제원;이진우;정정교;김용태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.435-438
    • /
    • 2005
  • Until now, a home appliance mostly has revealed physical quantities created by the standpoint of engineers, by using the A-weighted sound pressure level and the sound power. It is, however, obviously impossible to characterize a complex sound with a single number. Many parameters must be considered. In addition to loudness, we must take into account frequency and amplitude variation over time, spectral balance, tonality, and many other attributes. Thus, in this research, the general tendency of consumer psychology was investigated for the refrigerator's sound. The noise from the refrigerator was evaluated by not only the simple sound pressure levels but also the consumer's sense of hearing. And also, in order to improve the quality of sound through the design change, the consumer's evaluation was analysed and related to the engineering quantities. With the several design changes, finally the most silence refrigerator in the world was developed with considering the consumer's hearing of sense.

  • PDF

Gauss-Markov 추정 기법을 이용한 디지탈 비트 동기화기 실현에 관한 연구 (A Study on the Realization of a Digital Bit Synchronizer using the Gauss-Markov Estimation Technique)

  • 배현덕;유흥균
    • 한국음향학회지
    • /
    • 제9권2호
    • /
    • pp.61-69
    • /
    • 1990
  • 디지틀 통신에서 매우 중요한 문제인 비트 동기화(bit synchronization)를 기저대역(baseband)의 PAM 신호에 대하여 weighted least square 추정 기법과 등가인 Gauss-Markov 추정 기법을 연구하였다. 백색 가우시안 확류분포를 갖는 잡음하에서, 천이 위상(Transition phase)과 데이터 레벨의 추정을 2차원적으로 동시에 수행하여 수신단에서 완전한 신호를 복원하는, 검파기 포함형의 비트 동기화기(synchronizer) 실현에 관한 연구를 수행하였다. 컴퓨터 시물레이션으로 실현성을 확인하였으며, 기존의 대표적 비트 동기화 방식인 maximum likelihood 추정 이론에 근거한 DTTL(digital data transition tracking loop)와 그리고 minimum likelihood 추정 기법에 근거한 방식과의 추정 오차성능을 비교 평가하였다.

  • PDF

추정 파라미터의 2차원 변환을 통한 기저대역 데이터 복원 및 그의 실현에 관한 연구 (A Study on the Baseband Data Recovery and its Realization via the 2-Dimensional Transformantion of Estimation Parameters)

  • 허동규;김기근;유흥균
    • 한국통신학회논문지
    • /
    • 제15권12호
    • /
    • pp.1044-1052
    • /
    • 1990
  • 비트 동기화(bit synchronization)를 기저 대역의 PAM 신호에 대하여 weighted least square 추정 기법과 등가인 Gauss Markov 추정을 이용하여 연구하였다. 백색 가우시안 확률 분포를 갖는 잡음하에서, 천이 위상과 데이터 레벨의 추정을 2차원적으로 동시에 수행하여 수신단에서 완전한 신호를 복원하는, 검파기 포함형의 비트 동기화기(synchronizer) 실현에 관한 연구를 수행하였다. 컴퓨터 시뮬레이션으로 실현성을 확인하였으며, 기존의 대표적 동기화 방식인 maximum likehood 추정 이론에 근거한 DTTL(digital data transition tracking loop)와 그리고 minimum likehood 추정 기법에 근거한 방식과의 추정 오차 성능을 비교 평가하였다.

  • PDF

A Relationship of Tone, Consonant, and Speech Perception in Audiological Diagnosis

  • Han, Woo-Jae;Allen, Jont B.
    • 한국음향학회지
    • /
    • 제31권5호
    • /
    • pp.298-308
    • /
    • 2012
  • This study was designed to examine the phoneme recognition errors of hearing-impaired (HI) listeners on a consonant-by-consonant basis, to show (1) how each HI ear perceives individual consonants differently and (2) how standard clinical measurements (i.e., using a tone and word) fail to predict these differences. Sixteen English consonant-vowel (CV) syllables of six signal-to-noise ratios in speech-weighted noise were presented at the most comfortable level for ears with mild-to-moderate sensorineural hearing loss. The findings were as follows: (1) individual HI listeners with a symmetrical pure-tone threshold showed different consonant-loss profiles (CLPs) (i.e., over a set of the 16 English consonants, the likelihood of misperceiving each consonant) in right and left ears. (2) A similar result was found across subjects. Paired ears of different HI individuals with identical pure-tone threshold presented different CLPs in one ear to the other. (3) Paired HI ears having the same averaged consonant score demonstrated completely different CLPs. We conclude that the standard clinical measurements are limited in their ability to predict the extent to which speech perception is degraded in HI ears, and thus they are a necessary, but not a sufficient measurement for HI speech perception. This suggests that the CV measurement would be a useful clinical tool.