• Title/Summary/Keyword: A-scan signal

Search Result 294, Processing Time 0.034 seconds

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

Organized Hematoma in the Maxillary Sinus (상악동에 발생한 organized hematoma)

  • Kim, Jae-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.473-477
    • /
    • 2010
  • Organized hematoma of the maxillary sinus is a rare, nonneoplastic benign lesion with locally destructive behavior that may mimic a malignancy. Clinically, symptoms do not usually occur while the lesion remains localized to the maxillary sinus. Because there is gradual enlargement of the lesion causing erosion and displacement of the adjacent bony structures, symptoms such as epistaxis, cheek swelling, nasal obstruc-tion, headache, and exophthalmos become manifest. Radiologically, unilateral cases are much more fre-quent than bilateral, and Waters' view shows complete opacity of the expanded maxillary sinus and some masses. CT scan shows a large heterogeneous enhancing mass causing considerable expansion of the max-illary sinus with bony erosion. On MR imaging, the mass usually has a variable signal intensity on T1- and T2- weighted images, ranging from low to high. After contrast administration, discrete areas of enhance-ment are present within the mass. Although the disease is essentially benign and nonneoplastic, differen-tial diagnosis from neoplastic disease including malignancy both clinically and radiologically has been always problematic. Accurate preoperative diagnosis of organized hematoma of the maxillary sinus is important to avoid unnecessary extensive surgery, because this condition is curative with a simple, conservative surgical approach and rarely recur. Organized hematoma of the maxillary sinus should be included in the differential diagnosis when patients have recurrent epistaxis, slow-growing mass of the cheek, nasal obstruction, and expansile mass in the maxillary sinus. A 33-year-old man was referred to the department of oral and maxillofacial surgery with a three-month history of slowly growing painful swelling of the left cheek. The mass of the maxillary sinus was resected by a Caldwell-Luc approach. Histopahtoly showed only a fibous encapsulated organized hematoma. To our knowledge, organized hematoma of the maxillary sinus has not been previously described in the Korean literature of the oral and maxillofacial surgery. We report a case of organized hematoma of the maxillary sinus presenting with an enlarging maxillary sinus mass.

Delayed Diagnosis of Cerebral Infarction after Complete Occlusion of ICA due to Blunt Head Trauma: A Case of Report (두부둔상 후 내경동맥손상으로 인한 뇌경색의 지연진단: 증례보고)

  • Yun, Jung-Ho;Ko, Jung Ho;Cho, Chun-Sung
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.190-194
    • /
    • 2015
  • Blunt cerebrovascular injury is defined as a vertebral or carotid arterial structural wall injury resulting from nonpenetrating trauma. Complete traumatic internal carotid artery occlusion is very rare condition accounting for 0.08~0.4 0f all trauma patients and believed to be associated with the greatest risk of ischemic stroke reported in 50~90% in a few small series. A 55-year-male was admitted with drowsy mentality and severe headache after a fall down accident. Brain computed tomography showed a subdural hematoma at the both frontal area with a fracture of the occipital skull bone. Two days after admission, he suddenly complained with a right side hemiparesis of motor grade 2. Brain magnetic resonance diffusion demonstrated multiple high flow signal changes from the left frontal and parietal lesion. Computed tomographic angiogram (CTA) revealed absence of the left ICA flow. Trans femoral cerebral angiography (TFCA) showed complete occlusion of the left internal carotid artery (ICA) at ophthalmic segment in the left ICA angiogram and flows on the left whole hemispheric lesions through the anterior communicating artery in the right ICA angiogram. We decided to conduct close observations as a treatment for the patient because of acute subdural hematoma and sufficient contralateral cerebral flow by perfusion SPECT scan. Two weeks after the accident, he was treated with heparin anticoagulation within INR 2~4 ranges. He recovered as the motor grade 4 without another neurologic deficit after 3 months.

  • PDF

Imaging Patterns of Bacillus Calmette-Guérin-Related Granulomatous Prostatitis Based on Multiparametric MRI

  • Seungsoo Lee;Young Taik Oh;Hye Min Kim;Dae Chul Jung;Hyesuk Hong
    • Korean Journal of Radiology
    • /
    • v.23 no.1
    • /
    • pp.60-67
    • /
    • 2022
  • Objective: To categorize multiparametric MRI features of Bacillus Calmette-Guérin (BCG)-related granulomatous prostatitis (GP) and discover potential manifestations for its differential diagnosis from prostate cancer. Materials and Methods: The cases of BCG-related GP in 24 male (mean age ± standard deviation, 66.0 ± 9.4 years; range, 50-88 years) pathologically confirmed between January 2011 and April 2019 were retrospectively reviewed. All patients underwent intravesical BCG therapy followed by a MRI scan. Additional follow-up MRI scans, including diffusion-weighted imaging (DWI), were performed in 19 patients. The BCG-related GP cases were categorized into three: A, B, or C. The lesions with diffusion restriction and homogeneous enhancement were classified as type A. The lesions with diffusion restriction and a poorly enhancing component were classified as type B. A low signal intensity on high b-value DWI (b = 1000 s/mm2) was considered characteristic of type C. Two radiologists independently interpreted the MRI scans before making a consensus about the types. Results: The median lesion size was 22 mm with the interquartile range (IQR) of 18-26 mm as measured using the initial MRI scans. The lesion types were A, B, and C in 7, 15, and 2 patients, respectively. Cohen's kappa value for the inter-reader agreement for the interpretation of the lesion types was 0.837. On the last follow-up MRI scans of 19 patients, the size decreased (median, 5.8 mm; IQR, 3.4-8.5 mm), and the type changed from A or B to C in 11 patients. The lesions resolved in four patients. In five patients who underwent prostatectomy, caseous necrosis on histopathology matched with the non-enhancing components of type B lesions and the entire type C lesions. Conclusion: BCG-related GP demonstrated three imaging patterns on multiparametric MRI. Contrast-enhanced T1-weighted imaging and DWI may play a role in its differential diagnosis from prostate cancer.

Study of the Weld Defects Identification Method by Ultrasonic Pulse Echo Patterns (초음파 펄스 에코 패턴으로 용접 결함 식별 방법 연구)

  • Kim, Won-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6114-6118
    • /
    • 2013
  • This study examined the ultrasonic pulse reflection method(UPRM) for testing each ultrasonic pulse waveform model(UPWM) based on weld defects. The sharp crack of a clear signal was generated. The echo height of the defective probes changed according to the location. In a long crack in a circle around the defective probes, the Swivel scanning echo height when using the particle was reduced drastically. The peaks in the echo were thin because the needle was pointed. The porosity defects arising from a single echo was sharp and crisp, but a number of pores of the collective reflection overlapped and ajagged echo was observed. Slag, slag inclusions, cracks, and defects at the Swivel scan of each particle using the echo shape showed difference in the degree. Cracks were revealed as sudden changes in the echo height of the slag inclusions: increase ${\rightarrow}$ decrease ${\rightarrow}$ increase ${\rightarrow}$ decrease. In addition, the location of a number of defects in the dense pore geometry, such as a typical echo sundry, revealed the shape in the slag. Poor penetration of the defect echo, revealed the cracks to have a sharp-edged, crack-like shape with an echo.

Sclerosing Meningioma : Radiological and Clinical Characteristics of 21 Cases

  • Kang, Ho;Kim, Jin Wook;Se, Young-Bem;Dho, Yun-Sik;Choi, Seung Hong;Park, Sung-Hye
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.584-589
    • /
    • 2016
  • Objective : A rare subtype of meningioma, sclerosing meningioma is not included in the current World Health Organization classification of meningiomas and is classified into the category of other morphological variation subtypes. Sclerosing meningioma is often misdiagnosed to other non-benign meningioma or malignant neoplasm, so it is important to diagnose sclerosing type correctly. We analyzed the radiological and clinical characteristics of a series of sclerosing meningiomas. Methods : Twenty-one patients who underwent surgery in one institute with a histopathologically proven sclerosing meningioma were included from 2006 to 2014. Eighteen tumors were diagnosed as a pure sclerosing-type meningioma, and 3 as mixed type. Magnetic resonance image was taken for all patients including contrast enhancement image. Computed tomography (CT) scan was taken for 16 patients. One neuroradiologist and 1 neurosurgeon reviewed all images retrospectively. Results : In the all 16 patients with preoperative CT images, higher attenuation was observed in the meningioma than in the brain parenchyma, and calcification was observed in 11 (69%). In 15 of the 21 patients (71%), a distinctive very low signal intensity appeared as a dark color in T2-weighted images. Nine of these 15 tumors (60%) exhibited heterogeneous enhancement, and 6 (40%) exhibited homogeneous enhancement that was unlike the homogeneous enhancing pattern shown by conventional meningiomas. Ten patients had a clear tumor margin without peritumoral edema. Conclusion : Although these peculiar radiological characteristics are not unique to sclerosing meningioma, we believe that they are distinctive features that may be helpful for distinguishing sclerosing meningioma from other subtypes.

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

Development of Three-Dimensional Gamma-ray Camera (방사선원 3차원 위치탐지를 위한 방사선 영상장치 개발)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Soon-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.486-492
    • /
    • 2015
  • Radiation source imaging system is essential for protecting of radiation leakage accidents and minimizing damages from the radioactive materials, and is expected to play an important role in the nuclear plant decommissioning area. In this study, the stereoscopic camera principle was applied to develop a new radiation imaging device technology that can extract the radiation three-dimensional position information. This radiation three-dimensional imaging device (K3-RIS) was designed as a compact structure consisting of a radiation sensor, a CCD camera, and a pan-tilt only. It features the acquisition of stereoscopic radiation images by position change control, high-resolution detection by continuous scan mode control, and stereoscopic image signal processing. The performance analysis test of K3-RIS was conducted for a gamma-ray source(Cs-137) in radiation calibration facility. The test result showed that a performance error with less than 3% regardless of distances of the objects.

Comparative optimization of Be/Zr(BH4)4 and Be/Be(BH4)2 as 252Cf source shielding assemblies: Effect on landmine detection by neutron backscattering technique

  • Elsheikh, Nassreldeen A.A.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2614-2624
    • /
    • 2022
  • Monte Carlo simulations were used to model a portable Neutron backscattering (NBT) sensor suitable for detecting plastic anti-personnel mines (APMs) buried in dry and moist soils. The model consists of a 100 MBq 252Cf source encapsulated in a neutron reflector/shield assembly and centered between two 3He detectors. Multi-parameter optimization was performed to investigate the efficiency of Be/Zr(BH4)4 and Be/Be(BH4)2 assemblies in terms of increasing the signal-to-background (S/B) ratio and reducing the total dose equivalent rate. The MCNP results showed that 2 cm Be/3 cm Zr(BH4)4 and 2 cm Be/3 cm Be(BH4)2 are the optimal configurations. However, due to portability requirements and abundance of Be, the 252Cf-2 cm Be/3 cm Be(BH4)2 NBT model was selected to scan the center of APM buried 3 cm deep in dry and moist soils. The selected NBT model has positively identified the APM with a S/B ratio of 886 for dry soils of 1 wt% hydrogen content and with S/B ratios of 615, 398, 86, and 12 for the moist soils containing 4, 6, 10, and 14 wt% hydrogen, respectively. The total dose equivalent rate reached 0.0031 mSv/h, suggesting a work load of 8 h/day for 806 days within the permissible annual dose limit of 20 mSv.