• 제목/요약/키워드: A photovoltaic system

검색결과 1,629건 처리시간 0.031초

RF/DC 스퍼티 성장한 ITO/Ag/ITO 투명전극 박막의 특성 연구 (Characterisitics of RF/DC Sputter Grown-ITO/Ag/ITO Thin Films for Transparent Conducting Electrode)

  • 이영재;김제하
    • Current Photovoltaic Research
    • /
    • 제10권1호
    • /
    • pp.28-32
    • /
    • 2022
  • We investigated the optical and electrical characteristics of ITO/Ag/ITO (IAI) 3-layer thin films prepared by using RF/DC sputtering. To measure the thickness of all thin film samples, we used scanning electron microscopy. As a function of Ag thickness we characterized the optical transmittance and sheet resistance of the IAI samples by using UV-Visible spectroscopy and Hall measurement system, respectively. While the thickness of both ITO thin films in the 3-layered IAI samples were fixed at 50 nm, we varied Ag layer thickness in the range of 0 nm to 11 nm. The optical transmittance and sheet resistance of the 3-layered IAI thin films were found to vary strongly with the thickness of Ag film in the ITO (50 nm)/Ag(t0)/ITO (50 nm) thin film. For the best transparent conducting oxide (TCO) electrode, we obtained a 3-layered ITO (50 nm)/Ag (t0 = 8.5 nm)/ITO (50 nm) that showed an avrage optical transmittance, AVT = 90.12% in the visible light region of 380 nm to 780 nm and the sheet resistance, R = 7.24 Ω/□.

가상구현 태양전지 시스템을 위한 태양전지의 새로운 모델링 (Analysis of New Solar Cell Model for the Virtual Implemented Solar Cell System)

  • 정병환;강병희;이명언;최규하
    • 전력전자학회논문지
    • /
    • 제11권1호
    • /
    • pp.79-89
    • /
    • 2006
  • 태양광발전시스템이 갖고 있는 전기적 출력특성이 일사량과 온도의 변화에 따라 크게 변화되므로 동일조건에서의 재현 또는 재실험이 불가능한 단점으로 실험적 분석에 대한 어려운 문제점을 갖고 있다. 태양광발전시스템의 실증적인 연구를 위하여 기후조건의 변화에도 실제 태양전지의 출력특성을 나타낼 수 있는 가상구현 시스템이 필요한데 이를 구현하기위한 기존의 이론적 모델은 온도와 일사량이 동시에 변화할 때 나타내지 못하는 약점이 있어 이론 보완하는 모델 연구가 우선적으로 필요하다. 따라서 본 논문에서는 태양전지 특성을 가상구현 할 수 있는 새로운 수학적 모델을 제안하였고 연구자가 원하는 특정조건이나 임의의 일사량과 온도에 대한 태양전지 특성을 가상구현 할 수 있음을 이론적 검토 및 시뮬레이션을 통하여 해석하였다. 또한 새로운 모델을 검증하기 위하여 태양전지 제조사의 데이터를 바탕으로 가상구현 태양전지 시스템을 실험해 비교해본 결과 최대전력점과 개방전압사이에서 5[%] 미만의 오차를 보여 태양전지 가상구현 시스템에 적용 타당성을 보였다.

태양광발전이 연계된 배전계통에서 보호협조기기의 오동작에 대한 최적 방안에 관한 연구 (A Study on the Optimal Method for Malfunction of Protection Devices in Distribution Systems Interconnected with Photovoltaic Systems)

  • 노대석;김찬혁;신창훈;정원욱
    • 한국산학기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.1599-1606
    • /
    • 2008
  • 태양광발전과 같이 자연에너지를 이용한 분산전원은 일정한 출력을 내는 기존의 전원보다 기후나 온도, 지형적인 영향을 많이 받는 간헐적인 전원이므로, 이들이 도입된 배전계통은 기존의 단 방향 공급형태의 배전계통과는 달리 부하와 전원이 혼재되어 운용되는 형태로 된다. 분산전원이 연계된 배전계통의 경우에는 분산전원의 출력용량의 여부에 따라 양방향의 전력조류가 발생할 가능성이 있어, 계통운용상 여러 가지의 문제점이 야기될 수 있다. 특히, 태양광발전이 배전선로에 연계되어 운전되는 경우, 동일 뱅크의 타 배전선로에서 사고가 발생하면 태양광발전이 연계된 건전한 배전선로의 보호협조기기(리클로져)가 오동작하는 사고가 발생하는 경우가 실 계통에서 빈번하게 발생하고 있다. 이에 의하여 건전한 선로의 부하가 정전을 경험하는 심각한 문제점이 발생한다. 따라서 본 논문에서는 이론적인 계산식인 대칭좌표법과 MATLAB/SIMULINK을 이용하여 모델링과 시뮬레이션을 수행하여, 상기의 보호기기의 오동작 메카니즘과 문제점을 분석하고, 이에 대한 개선 방안을 제시하였다.

데이터를 활용한 태양광 발전 시스템 모듈온도 및 발전량 예측 (Prediction of module temperature and photovoltaic electricity generation by the data of Korea Meteorological Administration)

  • 김용민;문승재
    • 플랜트 저널
    • /
    • 제17권4호
    • /
    • pp.41-52
    • /
    • 2021
  • 본 연구에서는 태양광발전 출력 및 모듈온도 값을 기상청 데이터를 이용하여 예측해보고 실측 데이터와 날씨, 일사량, 주변온도, 풍속별로 비교 분석해보았다. 날씨별 예측정확도는 눈이 오거나, 새벽에 해무가 끼는 날의 데이터를 가장 많이 보유한 맑은날의 데이터의 예측정확도가 가장 낮았다. 일사량에 따른 모듈온도와 발전량의 예측정확도는 일사량이 커질수록 정확도가 떨어졌으며, 주변 온도에 따른 예측정확도는 모듈온도는 주변 온도가 커질수록, 발전량은 주변온도가 낮을수록 예측정확도가 떨어졌다. 풍속은 모듈온도와 발전량 모두 풍속이 높아질수록 예측정확도가 감소하였지만, 풍속이 영향 다른 기상조건에 의한 영향보다 미미하여 그 상관관계를 정의하기가 어려웠다.

태양광 발전시스템의 최대전력치 추종을 위한 퍼지 제어기의 디지털 설계 (Design of a fuzzy logic controller for MPPT of a photovoltaic system)

  • 이우희;김형진;천경민;이흥주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.358-361
    • /
    • 2006
  • 태양전지는 일사량에 따라 그 출력특성이 변하기 때문에 전지로부터 최대출력을 얻기 위해서는 컨버터에 의한 최대 전력점 추종제어가 필요하다. 본 논문에서는 태양광 발전시스템의 최대전력추종을 위해 퍼지이론을 도입한 퍼지제어기를 설계하였다. 퍼지제어기의 디지털 설계를 위해 태양광 발전시스템을 각 부분을 구성하고, FPGA를 사용하여 제어기를 구현하였다. 또한 실험을 통해 FPGA의 퍼지제어기로서의 구현가능성을 발견하고 그 타당성을 입증하고자 한다.

  • PDF

50[W]급 태양전지의 가상 구현을 위한 모듈의 직$\cdot$병렬 연결 특성 해석 및 제어 (Analysis and Control of Series$\cdot$Parallels Connection Characteristics for Virtual Implementation of 50[W] Solar Cell Module)

  • 한정만;류태규;고재석;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.53-57
    • /
    • 2002
  • The solar energy is purity and infinity. Solar power converter were used to convert the electrical energy from the solar arrays to a stable and reliable power source. So many countries research this solar energy system The photovoltaic system is construct many solar cell array. In this paper, new implementation solar system was showed buck converter that V-I curve produced. This system can be used to study the short-term and long-term performances of solar cell and efficiency. This system is a far more cost effective and reliable replacement for field and outdoor flight testing. Study of buck converter, analysis and control series or parallels connection characteristics of solar cell way.

  • PDF

Capacity Optimizing method of Distributed Generators in Stand-Alone Microgrid Considering Grid Link-Characteristics

  • Han, Soo-Kyeong;Choi, Hyeong-Jin;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1483-1493
    • /
    • 2018
  • Recently, more power facilities are needed to cope with the increasing electric demand. However, the additional construction of generators, transmission and distribution installations is not easy because of environmental problems and citizen's complaints. Under this circumstance, a microgrid system with distributed renewable resources emerges as an alternative of the traditional power systems. Moreover, the configuration of power system changes with more DC loads and more DC installations. This paper is written to introduce an idea of a genetic algorithm-based solution to determine the optimal capacity of the distributed generators depending on the types of system configuration: AC-link, DC-link and Hybrid-link types. In this paper, photovoltaic, wind turbine, energy storage system and diesel generator are considered as distributed generators and the feasibility of the proposed algorithm is verified by comparing the calculated capacity of each distributed resource with HOMER simulation results for 3 types of system configuration.

파라미터 설계방식을 이용한 PV시스템의 최적설계 (Optimum design of PV system used by parameter design method)

  • 정병호;최연옥;최문한;이강연;백형래;조금배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.64-66
    • /
    • 2007
  • Photovoltaic power systems convert sunlight directly into electricity. A residential PV power system enables a homeowner to generate some or all of their daily electrical energy demand on their own roof, exchanging daytime excess power for future energy needs In this paper, It was suggested that new design method for PV system installation for the purpose of system efficiency improvement. and according to loss parameter compensation method, designed for the PV system and investigated through the simulation practically.

  • PDF

대용량 태양광전원이 연계된 배전선로에 있어서 보호협조기기의 최적 운용알고리즘 (Optimal Operation Algorithm of Protection Devices in Distribution Systems With PV System)

  • 권순환;이후동;남양현;노대석
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.17-26
    • /
    • 2018
  • 최근, 대용량의 태양광전원이 연계된 배전계통은 기존의 단방향과 달리 양방향의 조류가 발생하고, 태양광전원의 연계위치 및 고장위치에 따라 사고전류의 크기와 방향이 변하여, 보호기기간의 협조시간차가 충분히 확보되지 않는 문제점이 발생할 수 있다. 또한, 태양광전원을 고려하지 않은 기존의 보호기기 정정치를 그대로 적용하고 있어 보호기기간의 협조시간차를 확보하기 어려운 상황이 발생하고 있다. 따라서 본 논문에서는 태양광전원이 연계된 선로에서 고려할 수 있는 3가지 Case의 보호기기 정정치 운용모드를 제시하고, 이를 바탕으로 태양광전원의 용량에 따른 최적의 보호협조 시간을 도출할 수 있는 알고리즘을 제안한다. 한편, 이를 바탕으로 보호협조 전용소프트웨어인 Off-DAS를 이용하여, 태양광전원이 연계된 배전계통을 모델링하고, 보호기기(변전소 계전기, 리클로저(Recloser), 고객계전기, 태양광전원 고객계전기)간의 협조시간차 특성을 분석한다. 실 계통을 대상으로 시뮬레이션을 수행한 결과, 본 논문에서 제시한 보호기기의 정정치 운용 모드와 정정치 산정 방식이 태양광 전원이 연계된 배전계통 보호기기간의 협조시간을 안정적으로 확보할 수 있음을 알 수 있었다.

태양광발전을 이용한 독립형 지하수 양수 시스템 개발 (Development of Stand-Alone Underground Water Pumping System using Photovoltaics System)

  • 이승훈;황정훈;조운식;김만일;이준기;박문희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF